• Title/Summary/Keyword: Guided Body

Search Result 146, Processing Time 0.021 seconds

Dosimetric Effects of Air Pocket during Magnetic Resonance-Guided Adaptive Radiation Therapy for Pancreatic Cancer

  • Jin, Hyeongmin;Kim, Dong-Yun;Park, Jong Min;Kang, Hyun-Cheol;Chie, Eui Kyu;An, Hyun Joon
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.104-111
    • /
    • 2019
  • Purpose: Online magnetic resonance-guided adaptive radiotherapy (MRgART), an emerging technique, is used to address the change in anatomical structures, such as treatment target region, during the treatment period. However, the electron density map used for dose calculation differs from that for daily treatment, owing to the variation in organ location and, notably, air pockets. In this study, we evaluate the dosimetric effect of electron density override on air pockets during online ART for pancreatic cancer cases. Methods: Five pancreatic cancer patients, who were treated with MRgART at the Seoul National University Hospital, were enrolled in the study. Intensity modulated radiation therapy plans were generated for each patient with 60Co beams on a ViewrayTM system, with a 45 Gy prescription dose for stereotactic body radiation therapy. During the treatment, the electron density map was modified based on the daily MR image. We recalculated the dose distribution on the plan, and the dosimetric parameters were obtained from the dose volume histograms of the planning target volume (PTV) and organs at risk. Results: The average dose difference in the PTV was 0.86Gy, and the observed difference at the maximum dose was up to 2.07 Gy. The variation in air pockets during treatment resulted in an under- or overdose in the PTV. Conclusions: We recommend the re-contouring of the air pockets to deliver an accurate radiation dose to the target in MRgART, even though it is a time-consuming method.

Diagnosis of Metastatic Undifferentiated Sarcoma by Endoscopic Ultrasound Guided Fine Needle Aspiration (EUS-FNA) (내시경초음파 세침흡인술을 통한 전이성 미분화육종의 진단)

  • Si Young Kim;Hee Seung Lee;Moon Jae Chung;Jeong Youp Park;Seungmin Bang;Seung Woo Park;Si Young Song
    • Journal of Digestive Cancer Research
    • /
    • v.5 no.2
    • /
    • pp.120-124
    • /
    • 2017
  • A-49-year-old male patient with no specific medical history was admitted to the clinic because of persistent epigastric pain radiating to back for 4 months. He had multiple parenchymal tumors in body and tail of pancreas, para-spinal muscle, and mediastinum on abdomen CT image. Cytologic examination of the pancreas which was done by endoscopic ultrasound guided fine needle aspiration (EUS-FNA) showed adenocarcinoma, whereas histological examination of the para-spinal mass showed undifferentiated sarcoma. Histologic examination of the pancreatic mass was made through endoscopic ultrasound guided fine needle biopsy (EUS-FNB) for accurate diagnosis, and the histologic examination of both the pancreas and posterior mediastinal mass showed the same undifferentiated sarcoma. Therefore, we reviewed the cytopathic tissue obtained from the pancreas for the first time, and it was confirmed to be similar to histologic findings in the mediastinal mass.

  • PDF

Bonding Stress Analysis of Cable Fairings used in Small Guided Missiles and Strength Tests of Bonding Materials (유도무기 케이블 페어링의 강도 해석 및 접착재 강도 시험)

  • Goo, N.-S.;Yoo, K.-J.;Shin, Y.-S.;Lee, Y.-H.;Cheong, H.-Y.;Kim, B.-H.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.6
    • /
    • pp.76-82
    • /
    • 2005
  • Cable fairings of guided missiles are generally used for protection of electric cables under aerodynamic heating and mechanical loading. The stress distributions between a cable fairing and missile main body along a cable fairing are necessary for its design. In this paper, a method for bonding stress and strength analysis of a cable fairing has been investigated and its computer program developed. Tensile and three-point bending tests of generally used bonding materials were also conducted to supply basic material properties for design of cable fairings.

NIR Fluorescence Imaging Systems with Optical Packaging Technology

  • Yang, Andrew Wootae;Cho, Sang Uk;Jeong, Myung Yung;Choi, Hak Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.25-31
    • /
    • 2014
  • Bioimaging has advanced the field of nanomedicine, drug delivery, and tissue engineering by directly visualizing the dynamic mechanism of diagnostic agents or therapeutic drugs in the body. In particular, wide-field, planar, near-infrared (NIR) fluorescence imaging has the potential to revolutionize human surgery by providing real-time image guidance to surgeons for target tissues to be resected and vital tissues to be preserved. In this review, we introduce the principles of NIR fluorescence imaging and analyze currently available NIR fluorescence imaging systems with special focus on optical source and packaging. We also introduce the evolution of the FLARE intraoperative imaging technology as an example for image-guided surgery.

Implantable Drug Delivery Systems-Design Process

  • Vincent, Croquet;Benolt, Raucent;Onori, Mauro
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.4
    • /
    • pp.40-46
    • /
    • 2006
  • The market of programmable implantable pumps has bound to a monopolistic situation, inducing high device costs, thus making them inaccessible to most patients. Micro-mechanical and medical innovations allow improved performances by reducing the dimensions. This affects the consumption and weight, and, by reducing the number of parts, the cost is also affected. This paper presents the procedure followed to design an innovative implantable drug delivery system. This drug delivery system consists of a low flow pump which shall be implanted in the human body to relieve pain. In comparison to classical known solutions, this pump presents many advantages of high interest in both medical and mechanical terms. The first section of the article describes the specifications which would characterize a perfect delivery system from every points of view. This concerns shape, medication, flow, autonomy, biocompatibility, security and sterilization ability. Afterwards, an overview of existing systems is proposed in a decisional tree. Positive displacement motorized pumps are classified into three main groups: the continuous movement group, the fractioned translation group and the alternative movement group. These systems are described and the different problems which are specific to these mechanisms are presented. Since none of them fully satisfy the specifications, an innovation is justified.. The decisional tree is therefore extended by adding new principles: fractioned refilling and fractioned injection within the fractioned translation movement group, spider guiding system within the alternative translation movement group, rotational bearing guided device and notch hinge guided device in the alternative rotation movement group.

EFFECTIVE DOSE MEASUREMENT FOR CONE BEAM COMPUTED TOMOGRAPHY USING GLASS DOSIMETER

  • Moon, Young Min;Kim, Hyo-Jin;Kwak, Dong Won;Kang, Yeong-Rok;Lee, Man Woo;Ro, Tae-Ik;Kim, Jeung Kee;Jeong, Dong Hyeok
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.255-262
    • /
    • 2014
  • During image-guided radiation therapy, the patient is exposed to unwanted radiation from imaging devices built into the medical LINAC. In the present study, the effective dose delivered to a patient from a cone beam computed tomography (CBCT) machine was measured. Absorbed doses in specific organs listed in ICRP Publication 103 were measured with glass dosimeters calibrated with kilovolt (kV) X-rays using a whole body physical phantom for typical radiotherapy sites, including the head and neck, chest, and pelvis. The effective dose per scan for the head and neck, chest, and pelvis were $3.37{\pm}0.29$, $7.36{\pm}0.33$, and $4.09{\pm}0.29$ mSv, respectively. The results highlight the importance of the compensation of treatment dose by managing imaging dose.

Magnetic Resonance-Guided Focused Ultrasound in Neurosurgery: Taking Lessons from the Past to Inform the Future

  • Jung, Na Young;Chang, Jin Woo
    • Journal of Korean Medical Science
    • /
    • v.33 no.44
    • /
    • pp.279.1-279.16
    • /
    • 2018
  • Magnetic resonance-guided focused ultrasound (MRgFUS) is a new emerging neurosurgical procedure applied in a wide range of clinical fields. It can generate high-intensity energy at the focal zone in deep body areas without requiring incision of soft tissues. Although the effectiveness of the focused ultrasound technique had not been recognized because of the skull being a main barrier in the transmission of acoustic energy, the development of hemispheric distribution of ultrasound transducer phased arrays has solved this issue and enabled the performance of true transcranial procedures. Advanced imaging technologies such as magnetic resonance thermometry could enhance the safety of MRgFUS. The current clinical applications of MRgFUS in neurosurgery involve stereotactic ablative treatments for patients with essential tremor, Parkinson's disease, obsessive-compulsive disorder, major depressive disorder, or neuropathic pain. Other potential treatment candidates being examined in ongoing clinical trials include brain tumors, Alzheimer's disease, and epilepsy, based on MRgFUS abilities of thermal ablation and opening the blood-brain barrier. With the development of ultrasound technology to overcome the limitations, MRgFUS is gradually expanding the therapeutic field for intractable neurological disorders and serving as a trail for a promising future in noninvasive and safe neurosurgical care.

PTP1B Inhibitory Secondary Metabolites from Marine-Derived Fungal Strains Penicillium spp. and Eurotium sp.

  • Sohn, Jae Hak;Lee, Yu-Ri;Lee, Dong-Sung;Kim, Youn-Chul;Oh, Hyuncheol
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.9
    • /
    • pp.1206-1211
    • /
    • 2013
  • The selective inhibition of PTP1B has been widely recognized as a potential drug target for the treatment of type 2 diabetes and obesity. In the course of screening for PTP1B inhibitory fungal metabolites, the organic extracts of several fungal species isolated from marine environments were found to exhibit significant inhibitory effects, and the bioassay-guided investigation of these extracts resulted in the isolation of fructigenine A (1), cyclopenol (2), echinulin (3), flavoglaucin (4), and viridicatol (5). The structures of these compounds were determined mainly by analysis of NMR and MS data. These compounds inhibited PTP1B activity with 50% inhibitory concentration values of 10.7, 30.0, 29.4, 13.4, and 64.0 ${\mu}M$, respectively. Furthermore, the kinetic analysis of PTP1B inhibition by compounds 1 and 5 suggested that compound 1 inhibited PTP1B activity in a noncompetitive manner, whereas compound 5 inhibited PTP1B activity in a competitive manner.

Patterns of Health Behavior for Weight Loss among Adults Using Obesity Clinics (비만클리닉에 내원하는 성인의 체중관리 행위)

  • Yang, Jin-Hyang;Cho, Myung-Ok;Lee, Kayoung
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.5
    • /
    • pp.759-770
    • /
    • 2012
  • Purpose: This ethnography was done to explore patterns of weight management behavior among adults using obesity clinics. Methods: The participants were 12 adults who were overweight or obese and 2 family members. Data were collected from iterative fieldwork in the obesity clinics of two hospitals. Data were analyzed using text analysis and taxonomic methods. Results: Weight management behaviors among participants varied according to the recognition of the body and motivation for weight control, Participants' behavior was discussed in the socio-cultural context of obesity. Patterns of weight management behavior among participants were categorized by focus: strategic self-oriented type including managements for the body as a social asset and for health, selective neglect type, and passive group value-oriented type including type dependent on others and managements for beauty. Conclusion: Participants' weight management behavior was guided by folk concepts of body and health. and constructed within the socio-cultural context. It is necessary for health care providers to understand physical and psychological problems arising from the repeated trials, excessive control of weight, and Western cultural discourse on beauty ideals among adults who are overweight or obese. Therefore, interventions should be tailored to address individual and community needs.

Verification of Missile Angular Velocity Calculation Using FMS (FMS를 이용한 대전차 유도탄의 각속도 계산식 검증)

  • Park, Eo-Jin;Kim, Wan-Shik;Park, Chan-Gook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.992-997
    • /
    • 2009
  • This paper focuses on the calculation of the missile angular velocity under the reduced sensor condition and its verification using the Flight Motion Simulator(FMS). The missile angular velocity is usually measured by the body gyroscopes, but we assume that the inertial sensors on the missile body are in the absence of pitch and yaw gyroscopes. Under this reduced sensor condition, this paper shows the missile angular velocity can be calculated by using the gimbal seeker gyroscope, the roll body gyroscope, the gimbal angle and its rate. The FMS experiment was carried out to verify the proposed algorithm.