• Title/Summary/Keyword: Guide tube

Search Result 127, Processing Time 0.032 seconds

Heat transfer performance of a helical heat exchanger depending on coil distance and flow guide for supercritical cryo-compressed hydrogen

  • Cha, Hojun;Choi, Youngjun;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.62-67
    • /
    • 2022
  • Liquid hydrogen (LH2) has a higher density than gaseous hydrogen, so it has high transport efficiency and can be stored at relatively low pressure. In order to use efficient bulk hydrogen in the industry, research for the LH2 supply system is needed. In the high-pressure hydrogen station based on LH2 currently being developed in Korea, a heat exchanger is used to heat up supercritical hydrogen at 700 bar and 60 K, which is pressurized by a cryogenic high-pressure pump, to gas hydrogen at 700 bar and 300 K. Accordingly, the heat exchanger used in the hydrogen station should consider the design of high-pressure tubes, miniaturization, and freezing prevention. A helical heat exchanger generates secondary flow due to the curvature characteristics of a curved tube and can be miniaturized compared to a straight one on the same heat transfer length. This paper evaluates the heat transfer performance through parametric study on the distance between coils, guide effect, and anti-icing design of helical heat exchanger. The helical heat exchanger has better heat transfer performance than the straight tube exchanger due to the influence of the secondary flow. When the distance between the coils is uniform, the heat transfer is enhanced. The guide between coils increases the heat transfer performance by increasing the heat transfer length of the shell side fluid. The freezing is observed around the inlet of distribution tube wall, and to solve this problem, an anti-icing structure and a modified operating condition are suggested.

An Experimental Study on the Characteristics of Temperature Distribution in Internal Space of a Tube for the Formal Change of Counterflow Type Vortex Tube (대향류형 보텍스 튜브의 노즐형상 변화011 따른 튜브 내부의 온도분포에 관한 실험적 연구)

  • 황승식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.69-76
    • /
    • 2002
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial and the radial temperature distribution in internal spare of a tube. From the study, fellowing conclusive remarks 7an be made. First, As the number of nozzles increase, separation point move into the hot exit. Second, When we use guide vane type nozzle, the axial temperature distribution constant over the 0.75 of air mass flow rate radio. Third, When we use Spiral type nozzle, axial and radial temperature distribution in the inner space is higher than another nozzle. Fourth, Axial and radial temperature distribution in the inner space vortex-tube is determined by separation point. And separation point is moved by changing of air mass flow rate ratio. At last, A heating apparatus is possible far vortex-tube to use.

A study on the minimal acupuncture using a modified guide tube for Korean female participants familiar with acupuncture therapy (침치료에 익숙한 한국의 여자 임상시험 피험자를 대상으로 한 침관 변형을 통한 Minimal acupuncture 경험)

  • Roh, Jin-Ju;Jung, Su-Kyoung;Choi, Min-Sun;Choi, Sun-Mi;Kim, Dong-Il
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.20 no.3
    • /
    • pp.200-212
    • /
    • 2007
  • Purpose: To find objective validity of minimal acupuncture using a modified guide tube as a method to verify the effect of acupuncture. Methods: Subjects of this study were participants of a randomized clinical trial which was practiced to verify the effect of acupuncture on postmenopausal hot flash. There were 2 arms of treatment, one's for active acupuncture group(AG) with manipulation and De qi, the other's for minimal acupuncture group(MG) using a modified guide tube which was designed to give minimal stimulation to the patient. After 8 weeks' treatment followed by 4 weeks' observation, participants were asked to fill in self-report forms on their education, previous experiences of acupuncture, original idea on the efficacy of acupuncture and recognition of blinding. Results: 19 participants of 26 in AG and 19 of 26 in MG completed the self-report form. There was no difference between AG and MG in their education(p=0.5976, Fisher exact test) and previous experiences of acupuncture(p=0.9999, Fisher exact test). In their original ideas on the efficacy of acupuncture, most of AG and MG respondents have been thought that acupuncture is very effective or quite effective, and there was no difference between 2 groups(p=0.5065). 16 of 19 in AG and 14 of 19 in MG believed that they underwent more effective way, there was no statistical difference between 2 groups(p=0.6928, Fisher exact test). Participants believed in undergoing more effective way not because they recognized treatment method, but they were satisfied with the effectiveness of treatment retrospectively. Conclusion: As the result of this study, these authors suggest that minimal acupuncture using a modified guide tube is acceptable as a method to verify the effect of acupuncture in acupuncture-familiar Korean culture. Also further studies on the stimulation-specific effect of minimal acupuncture are demanded.

  • PDF

Assessment of London underground tube tunnels - investigation, monitoring and analysis

  • Wright, Peter
    • Smart Structures and Systems
    • /
    • v.6 no.3
    • /
    • pp.239-262
    • /
    • 2010
  • Tube Lines has carried out a "knowledge and investigation programme" on the deep tube tunnels comprising the Jubilee, Northern and Piccadilly lines, as required by the PPP contract with London Underground. Many of the tunnels have been in use for over 100 years, so this assessment was considered essential to the future safe functioning of the system. This programme has involved a number of generic investigations which guide the assessment methodology and the analysis of some 5,000 individual structures. A significant amount of investigation has been carried out, including ultrasonic thickness measurement, detection of brickwork laminations using radar, stress measurement using magnetic techniques, determination of soil parameters using CPT, pressuremeter and laboratory testing, installation of piezometers, material and tunnel segment testing, and trialling of remote photographic techniques for inspection of large tunnels and shafts. Vibrating wire, potentiometer, electro level, optical and fibre-optic monitoring has been used, and laser measurement and laser scanning has been employed to measure tunnel circularity. It is considered that there is scope for considerable improvements in non-destructive testing technology for structural assessment in particular, and some ideas are offered as a "wish-list". Assessment reports have now been produced for all assets forming Tube Lines' deep tube tunnel network. For assets which are non-compliant with London Underground standards, the risk to the operating railway has to be maintained as low as reasonably practicable (ALARP) using enhanced inspection and monitoring, or repair where required. Monitoring techniques have developed greatly during recent years and further advances will continue to support the economic whole life asset management of infrastructure networks.

Manufacturing Process Effect on Strength and Corrosion Properties of Zr Alloys for Fuel Guide Tube (핵연료 안내관용 지르코늄 합금의 강도 및 부식 성능에 미치는 제조공정 영향)

  • Kim, Hyun-Gil;Kim, Il-Hyun;Choi, Byung-Kwan;Park, Sang-Yoon;Park, Jeong-Yong;Jeong, Yong-Hwan
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.12
    • /
    • pp.852-859
    • /
    • 2009
  • The manufacturing process of zirconium alloys is an import factor to increase their strength and corrosion resistance. In order to find an improved manufacturing process of zirconium alloys in both Zr-1Nb-1Sn-0.1Fe (Alloy-A) and Zr-1.5Nb-0.4Sn-0.2Fe-0.1Cr (HANA-4) for fuel guide tubes, sheet samples were prepared by applying two- and three-step processes that were controlled by an annealing and reduction condition. The mechanical strength and corrosion resistance of both alloys were increased by applying the twostep process rather than the three-step process. From a matrix analysis using TEM, the property improvement is related to the decrease of the precipitate mean diameter with an application of the two-step process. In a comparison of the strength and corrosion properties between Alloy-A and HANA-4, the performance of HANA-4 was feasible for application to fuel guide tubes.

A Study on Hydraulic Performance of Francis Turbine for Small Hydropower Plants (소수력 발전용 프란시스 수차의 수력학적 성능에 관한 연구)

  • Choi, J.S.;Kim, I.S.;Moon, C.J.;Kim, O.S.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.687-689
    • /
    • 2005
  • Francis turbine of commercial small hydro -power plants under 10kw which is investigate a flow characterist and an efficiency in the research which it sees, the problem and an improvement is investigate. In the research which it is simply model with casing, guide-vane, runner, draft tube for simulation numerical analysis of small-sized Francis turbine. model uses the Gambit and it composes with approximately 800,000 nonuniform lattices. Solutions are investigate the hydraulic characteristics against an outward angle of guide vane, the number of guide vane, head(inlet velocity) by using FLUENT which is a commercial business code.

  • PDF

Spray Visualization of the Gas Turbine Vaporizer (가스터빈 기화기의 분무 가시화 연구)

  • Jo, Sungpil;Joo, Milee;Choi, Seongman;Rhee, Dongho
    • Journal of ILASS-Korea
    • /
    • v.24 no.3
    • /
    • pp.130-136
    • /
    • 2019
  • Spray visualization of a vaporizer fuel injection system of a micro turbo jet engine was experimentally studied. The fuel heating by combustion was simulated by the high pressure steam generator and combustor inlet air from the centrifugal compressor was simulated by compressed air stored in the high pressure air tank. Spray visualization was performed with single vaporizer, and then six vaporizers which are same number of micro turbojet engine were used. As a results, the spray characteristics of the vaporizer were understood with pressure difference of the combustor inlet air and the fuel supply pressure. Spray angles with three types of vaporizer configuration were measured. In the results, guide vane configuration has a wider spray angle than the straight tube and smooth curve tube with a swirler, so it is expected that the fuel will be effectively distributed inside the combustor flame tube.

Settling time of dental x-ray tube head after positioning (치과용 X-선 관구의 조정시간)

  • Yoon Suk-Ja;Kang Byung-Cheol;Wang Se-Myung;Koh Chang-Sung
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.159-165
    • /
    • 2002
  • Purpose: The aim of this study was to introduce a method of obtaining the oscillation graphs of the dental x-ray tube heads relative to time using an accelerometer. Materials and Methods: An Accelerometer, Piezotron type 8704B25 (Kistler Instrument Co., Amherst, NY, USA) was utilized to measure the horizontal oscillation of the x-ray tube head immediately after positioning the tube head for an intraoral radiograph. The signal from the sensor was transferred to a dynamic signal analyzer, which displayed the magnitude of the acceleration on the Y-axis and time lapse on the X -axis. The horizontal oscillation of the tube head was measured relative to time, and the settling time was also determined on the basis of the acceleration graphs for 6 wall type, 5 floor-fixed type, and 4 mobile type dental x-ray machines. Results : The oscillation graphs showed that tube head movement decreased rapidly over time. The settling time varied with x-ray machine types. Wall-type x-ray machines had a settling time of up to 6 seconds, 5 seconds for fixed floor-types, and 1 I seconds for the mobile-types. Conclusion: Using an accelerometer, we obtained the oscillation graphs of the dental x-ray tube head relative to time. The oscillation graph with time can guide the operator to decide upon the optimum exposure moment after x-ray tube head positioning for better radiographic resolution.

  • PDF