• 제목/요약/키워드: Guide tube

검색결과 127건 처리시간 0.022초

딥스틱게이지형 소형 엔진열화감지센서 개발 (Development of a Dipstick Gage Type Small Engine oil Deterioration Detection Sensor)

  • 전상명
    • Tribology and Lubricants
    • /
    • 제29권2호
    • /
    • pp.77-84
    • /
    • 2013
  • A small engine-oil-deterioration detection sensor was developed and installed at the tip of a dipstick gage. The sensor part was manufactured using printed circuit board (PCB) manufacturing technology. A set of sensor covers was installed in order to protect the sensor and realize good signal stability. The small engine-oil-deterioration detection sensor system comprised a dual sensor having etched copper electrodes coated with gold and ceramic, a flexible PCB (FPCB) acting as electric wire, and a dummy PCB with only a lock connector. The sensor can easily be installed by insertion through the guide tube of a dipstick gage. Thus, a driver can easily handle it without further installation equipment. The sensor can determine the level of deterioration in the engine oil by estimating the corresponding dielectric constant of the engine oil.

프란시스 수차의 수력학적 성능해석 (Hydraulic Performance Analysis of a Francis Turbine)

  • 윤의수;오형우;박무룡
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.53-56
    • /
    • 2006
  • The hydraulic performances of a Francis turbine which had been designed and tested by IMHEF were calculated with a commercial code and compared with the IMHEF test results. The non-dimensional specific speed of the turbine is 0.5, the runner exit diameter 0.4m and maximum efficiency 93.1% respectively. To make the calculation of the turbine more exact, the stay vanes, the guide vane, the runner and the draft tube were calculated simultaneously. The calculation results gave a quite good agreement with the IMHEF test data, and therefore it is expected that the present calculation technique will be utilized for the hydraulic design of efficient Francis turbines.

  • PDF

수력터빈의 압력변동에 의한 로터 진동 (Vibration of the Rotor due to Pressure Fluctuation in a Hydraulic Turbine)

  • 김기섭;김호종;박영하;이욱;전재영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1027-1033
    • /
    • 2000
  • This paper describes the characteristics of vibration of a hydraulic turbine mainly due to cavitation occurrence. The analysis of vibration spectra of the turbine shaft shows that hub vortex cavitation occurs in the downstream of the turbine runner, which is verified from coherence analysis between shaft vibration displacement and dynamic pressure at the draft tube. Even though acceleration level measured at the guide vane lever, which is usually used for evaluation of cavitations performance, is decreased during forced aeration, it is found from the analysis of dynamic pressure spectra that cavitation around runner blades still remains unchanged. It is also found that lateral vibration of the turbine shaft is mainly due to the hub vortex cavitation of the turbine runner.

  • PDF

CFD를 이용한 축류 유체 터빈 설계: 블레이드 수에 따른 성능 연구 (DESIGN OF AXIAL FLOW HYDRAULIC TURBINE USING CFD APPROACH: STUDY OF TURBINE PERFORMANCE ACCORDING TO THE NUMBER OF RUNNER BLADE)

  • 임형섭;김성완;백제현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.561-566
    • /
    • 2011
  • In this paper, 1-D design of axial flow hydraulic turbine including runner blades, spiral casing with distributors(guide vanes and stay vane), and draft tube was conducted and then 3-D flow analysis was carried out using CFX-12.1. The results of 3 runners showed that with an increase in the number of blades, the flow rate and the power of the turbine system increased. On the other hand. the runner loss was not directly connected with the number of blades. As a result, proper blade number could be selected and more than 100kW small hydraulic turbine could be designed.

  • PDF

작동형 내시경의 성능 해석 및 제어에 관한 연구 (A Study on Performance-Analysis and Control of the Active Catheter)

  • 정종필;김종현;이장무
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.556-561
    • /
    • 2000
  • This paper deals with the control of an active bending actuator fur a catheter. The bending actuator with 40mm in length utilizes three zigzag SMA (shape memory alloy) springs which are equally located in the circumference between inner $({\phi}2.5 mm)$ and outer $({\phi}3.0mm)$ tube. It is purposed on realization of desired bending angle $(90^{\circ})$ and direction $(360^{\circ})$. It is also installed in front of the catheter and used to guide a path at extremely bent or branched blood vessel. The performance-analysis of the bending actuator are investigated fur the purpose of optimizing the control of the bending actuator. The analog joy stick is used to command a bending angle and direction for the fast and accurate response. According to the commands of the joy stick, tensile force of each SMA spring is computed and obtained by controlling the temperature of each SMA spring using PWM (pulse width modulation) of supplied electric power.

  • PDF

현열 축열조의 성능에 관한 엑서지 해석 (Exergy analysis on the storage performance of the sensible heat storage unit)

  • 김시범;권순석
    • 한국해양공학회지
    • /
    • 제2권1호
    • /
    • pp.176-182
    • /
    • 1988
  • The exergy analysis on the heat storage performance of the senible heat storage unit which consists of the heat storage material in the concentric annulus and the hot fluid flowing through the inner tube is performed. Heat transfer characteristics which are necessary for the performance of the exergy analysis is obtained from the energy balance equations and the second law of thermodynamics. As the index of heat storage performance, the exergy lossnumber $N_{s}$, and exergy storage ratio from the concepts of the second law of thermodynamics are defined. Results are ovtained for the grometry of the storage unit, the Biot number Bi, ambient temperature $T_{o}$ as parameters. From these results the exergy storage ratio can be considered as the efficiency of the hat storage unit and is introduced as a guide to design.

  • PDF

비자성체 링을 사용한 솔레노이드 액츄에이터의 작동속도 향상법 (Speed Increasing Method of Solenoid Actuator Using a Non-Magnetic Ring)

  • 성백주;이은웅;김형의
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.6-8
    • /
    • 2005
  • The plunger speed of solenoid actuator is affected by mass of plunger, magnetic motive force, inductance, and return spring. These factors are not independent but related with each other according to design characteristics of solenoid actuator. So, it is impossible to change the designed value for the purpose of increasing plunger speed. In this study, we have analyzed the characteristics of high-speed solenoid actuator having a non-magnetic ring which plays a role to concentrate the effective magnetic flux into plunger. For more detailed analysis, we have performed FEM analysis and decided the optimal attaching position and length on the guide tube based on these results. And, we proved the propriety of the non-magnetic ring effect by experiments.

  • PDF

PWM 제어형 고속 전자석의 특성 해석 (Characteristic Analysis of PWM Controlled High-Speed Magnet)

  • 성백주;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1309-1311
    • /
    • 2005
  • The operating speed of PWM controlled high speed magnet is affected by mass of plunger magnetic motive force inductance and return spring It is impossible to change the value of them for the purpose of increasing the speed because these factors are related with each other This paper introduces a speed increasing method using a non magnetic ring which is welded in the middle of magnetic guide tube and also presents the characteristic equations results of FEM analysis for magnetic flux distribution and computer simulation results for the dynamic characteristics of plunger motion And we proved the effect of non magnetic ring by experiments using a prototype

  • PDF

Wire Guided Cannulation Facilitates Endoscopic Management of Buried Bumper Syndrome: A Novel Technique

  • Peck, Jacquelin;Sapp, Kaitlin;Wilsey, Alexander;Wilsey, Michael
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제22권1호
    • /
    • pp.86-89
    • /
    • 2019
  • Buried bumper syndrome is a rare but potentially severe complication of percutaneous endoscopic gastrostomy tube insertion. Though this complication is uncommon, it may lead to pressure necrosis, bleeding, perforation, peritonitis, sepsis, or death. Each case of buried bumper syndrome is unique in terms of patient comorbidities and anatomic positioning of the buried bumper. For this reason, many approaches have been described in the management of buried bumper syndrome. In this case report, we describe the case of an adolescent Caucasian female who developed buried bumper syndrome three years after undergoing percutaneous endoscopic gastrostomy insertion. We review diagnosis and management of buried bumper syndrome and describe a novel technique for bumper removal in which we use a guide wire in combination with external traction to maintain a patent gastrostomy lumen while removing the internal percutaneous endoscopic gastrostomy bumper.

세척공정의 트리클로로에틸렌 TWA 및 STEL 평가 사례 (TCE Exposure Assessment of Cleaning Workers)

  • 김현수
    • 한국산업보건학회지
    • /
    • 제33권1호
    • /
    • pp.3-5
    • /
    • 2023
  • Objective: This study introduces exposure concentrations of time-weighted average standard (TWA) evaluation and short-time exposure standard (STEL) evaluation for trichloroethylene in the cleaning process. Methods: Trichloroethylene measurement was conducted according to the KOSHA Guide (A-24-2019) method. It was carried out twice. Results: As a result of the first measurement, TWA concentration exceeded 4 times the exposure standard and STEL concentration exceeded 16 times, but the inaccuracy and breakthrough of the collection time could not be considered, so the second measurement was conducted. The second measurement result was lower than the first measurement result, but exceeded the exposure standards (TWA, STEL). Conclusions: We were able to confirm that the exposure level of workers in the cleaning process using trichloroethylene exceeded the exposure standard. And it is also considered necessary to grasp the approximate concentration using a detector tube in the preliminary survey.