• Title/Summary/Keyword: Guide surgery

Search Result 290, Processing Time 0.03 seconds

A Guide to Designing a Case Series in Plastic Surgery (성형외과 영역에서 임상증례군 보고 형식의 논문 작성 가이드)

  • Kim, Tae-Gon;Kim, Il-Kug
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.1
    • /
    • pp.1-3
    • /
    • 2012
  • The case series is a descriptive study that follows a group of patients who have a similar diagnosis or who are undergoing the same procedure and is the most prevalent type of research in the field of plastic surgery. Results of case series can generate hypotheses that are useful in designing further studies, including randomized controlled trials or a prospective cohort study. However, no causal inferences should be made from case series regarding the efficacy of the investigated treatment. The authors provide a guide to the design and report on the case series.

Comparison of the biodegradability in the membranes for the guided bone regeneration: preliminary study

  • Lee, Chang-Hyeon;Kang, Yei-Jin;Jo, You-Young;Kweon, HaeYong;Kim, Seong-Gon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.39 no.1
    • /
    • pp.9-13
    • /
    • 2019
  • In this study, 4 different types of GBR membrane were undergone for bio-degradability test; Silk mat from silkworm cocoon (TDI), silk mat from flatwise-spun (FS), collagen membrane (OssGuide), and dPTFE membrane (Cytoplast). Each material was segmented in 10.00 mm length and 0.3 mm thickness. The samples were put into the normal saline at $37^{\circ}C$ for 2 weeks. After that, yield strength and tensile strain were measured and compared them with those of before treatment. The morphology of the membranes was observed by SEM. Tensile strain of FS was significantly increased at 2 weeks' normal saline treatment (P=0.018). When compared to OssGuide, TDI and FS showed significantly higher tensile strain at 2 weeks' normal saline treatment (P<0.05). In the SEM images, there were no significant changes in Cytoplast, TDI, and FS after 2 weeks' treatment. However, OssGuide showed damaged surface after 2 weeks' treatment. In conclusion, both TDI and FS did not have any evidence of biodegradability at 2 weeks' observation in normal saline treatment. However, OssGuide showed more than 20 % decrease in yield strength and tensile strain.

Computer-guided implant surgery and immediate provisionalization by chair-side CAD-CAM: A case report (진료실 CAD-CAM에 의한 컴퓨터 가이드 임플란트 수술과 즉시 임시보철치료: 증례보고)

  • Hyun, Sang Woo;Lee, sungbok Richard;Lee, Suk Won;Cho, Young Eun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.478-486
    • /
    • 2021
  • This report demonstrates a method of generating a chair-side and computer-aided template for implant surgery based on the Top-Down and restoration-driven concept. Compared to the traditional CAD-CAM process which requires multiple steps to be taken between dental clinic and laboratory, this alternative procedure, VARO guide system (VARO Guide, CAD, Pre-Guide, VARO-mill, NeoBiotech, Seoul, South Korea) enables accurate and patient-friendly implant surgery as well as immediate provisional restoration in a single visit. First, bite-registration at centric jaw relation and CBCT were taken using the Pre-Guide. The CBCT data was then reorganized directly through the chair-side CAD, and we could determine the most appropriate 3-dimensional position of implant. The STL file was extracted and put into the chair-side CAM (VARO-mill) to fabricate a VARO. This surgical guide allowed the implants to be accurately positioned into the planned sites within an hour.

Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis (Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례)

  • Kim, Seong-Mo;Park, Jin-Hong;Ryu, Jae-Jun;Shin, Sang Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.126-133
    • /
    • 2018
  • The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.

Analysis of Exit Site of Guide Pin Using Tansglenoid Suture Technique in Bankart and SLAP Lesion (Bankart 병변과 SLAP 병변에서 경견관절와 술식시 Guide Pin 출구의 분석)

  • Rhee Kwang-Jin;Shin Hyun-Dae;Byun Ki-Yong;Kim Young-Mo;Joo Yong-Bum;Kim Kyung-Cheon
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.2
    • /
    • pp.105-109
    • /
    • 2005
  • Purpose: To Analyze the exit site of pin inserted at the anterior glenoid rim in the reconstruction of the Bankart lesion and SLAP lesion using transglenoid suture technique. Materials and Methods: In the twenty adult right cadeveric scapula, insertions of pin were performed using guide at the position of 1, 2, 3 O'clock of glenoid rim. We measured the exit site of dorsal surface of the scapula by medial distance from sagittal plane of lateral border of scapular spine and the vertical distance from posterior border of the scapular spine. Results: When the pin was inserted caudally within 10 degree, at the position of 1, 2, 3 O'clock, the medial distance from lateral border of the scapula is averaged 29.4, 19.2, 34.0 mm respectively and the vertical distance from posterior border of the scapular spine is averaged 15.0, 18.6, 17.2 mm respectively. When the pin was inserted caudally within 20-30 degree, the medial distance is averaged 14.6, 14.2, 15.8 mm respectively and the vertical distance is averaged 31.6, 31.9, 32.1 mm respectively. Conclusion: When the pin was inserted caudally within ten degrees using the guide, the pin exit appeared at the more medial side of the base of scapular spine and the more inferior of scapular spine. This can make the firm suture tied over scapular spine during repair SLAP and the Bankart lesion, and also prevent the injury of suprascapular nerve.

Full mouth rehabilitation of a patient with severe periodontitis using immediate loading after computer aided flapless implant surgery (심한 치주질환을 가진 환자에서 computer aided flapless surgery와 즉시 부하를 통한 전악 구강 회복 증례)

  • Kang, Seong hun;Choi, Yeon jo;Ryu, Jae jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.46-55
    • /
    • 2018
  • Oral rehabilitation of a patient having severe periodontitis with alveolar bone resorption and periodontal inflammation presents a challenge to clinicians. However, if appropriate implant placement according to the bone shape is selected, unnecessary bone grafting or soft tissue surgery can be minimized. In recent years, using cone beam CT and software, it has become possible to operate the planned position with the surgical guide made with 3D printing technology. This case was a 70 years old female patient who required total extraction of teeth due to severe periodontitis and performed a full-mouth rehabilitation with an implant - supported fixed prosthesis. During the surgery, the implant was placed in a flapless manner through a surgical guide. Immediate loading of the temporary prosthesis made by CAD/CAM method before surgery was done. Since then, we have produced customized abutments and zirconia prostheses, and have reported satisfactory aesthetic and functional recovery.

Flapless implant surgery on atrophied alveolar ridge in a patient with growth disorder (성장 장애를 가진 부분 무치악 환자에서 위축된 골에 무피판 임플란트 수술 증례)

  • Lee, Du-Hyeong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.170-175
    • /
    • 2014
  • The growth disorder influences craniofacial development and early loss of permanent teeth. This case reports the importance of computerized tomography (CT) and surgical guide to identify horizontal bone loss, adjacent teeth and to guide drills when placing implants in a short stature patient. The patient has idiopathic short stature and the 3rd grade of intellectual disability. To recover posterior mandibular teeth, implant treatment was planned. CT images showed that the adjacent teeth were located markedly to the buccal side. A CT-based surgical guide was fabricated and implants was placed using flapless surgery. Bone dehiscence and fenestration may happen when the surgical guide was fabricated just based on adjacent clinical crowns. Thus, it is essential to analysis bone and teeth and to make surgical guide through CT, especially in atrophied bone on grow disorder patients. Furthermore, systematic researches are recommended to elucidate the relationship between growth disorder and tooth malposition.

Computer Simulation Surgery for Mandibular Reconstruction Using a Fibular Osteotomy Guide

  • Jeong, Woo Shik;Choi, Jong Woo;Choi, Seung Ho
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.584-587
    • /
    • 2014
  • In the present study, a fibular osteotomy guide based on a computer simulation was applied to a patient who had undergone mandibular segmental ostectomy due to oncological complications. This patient was a 68-year-old woman who presented to our department with a biopsy-proven squamous cell carcinoma on her left gingival area. This lesion had destroyed the cortical bony structure, and the patient showed attenuation of her soft tissue along the inferior alveolar nerve, indicating perineural spread of the tumor. Prior to surgery, a three-dimensional computed tomography scan of the facial and fibular bones was performed. We then created a virtual computer simulation of the mandibular segmental defect through which we segmented the fibular to reconstruct the proper angulation in the original mandible. Approximately 2-cm segments were created on the basis of this simulation and applied to the virtually simulated mandibular segmental defect. Thus, we obtained a virtual model of the ideal mandibular reconstruction for this patient with a fibular free flap. We could then use this computer simulation for the subsequent surgery and minimize the bony gaps between the multiple fibular bony segments.