• Title/Summary/Keyword: Guidance Device

Search Result 149, Processing Time 0.023 seconds

A Study on Inhalation Force Improvements of Ventilation Hood For Removed a Pollution Source (유해물질 제거를 위한 국소배기장치 후드의 흡입력 증가에 관한 연구)

  • Yang, Ho-Dong;Kim, Young-Sun;Oh, Yool-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2327-2332
    • /
    • 2007
  • This study investigates on the inhalation force improvements of hood consisted one of the local ventilation systems attached the new device named as gas-guidance-device for removed a pollution source. The numerical method applying finite element method is calculated the velocity and pressure distributions of a moving fluid at the beginning and the inside of a hood with and without the gas-guidance-device in hood. And, the experimental study is measured the wind velocity using the anemometer at the same condition of numerical study. Also, the optimum shape of gas-guidance-device which is suitable for hood shape derived from the numerical and experimental results. The results of this study is supplied the important data to an industrial field for control of a pollution source in the engineering aspect. Moreover, the introduced technique of hood attached the gas-guidance-device is very useful to remove the harmful materials such as dust and waste happened in the manufacturing factory.

  • PDF

Design of CC2540-based Route Guidance System for Visually Impaired Person (CC2540을 이용한 시각장애인용 길안내 시스템 설계 및 구현)

  • Yoo, Hyun-Ho;Choi, Byung-Jae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.1
    • /
    • pp.47-56
    • /
    • 2016
  • There are many assistive devices for the visually impaired. They are becoming smart. In this paper, we propose a device that help route guidance for a visually impaired person. It is composed of a smart phone, cane, and hands-free devices. The smart phone helps a route guidance. The cane detects an obstacle and transmits it to the hands-free device. The hands-free device communicates with a visually impaired person. We here present their architecture, signal flow, configuration, and their circuit diagrams.

ISO14971:2019 Detailed Analysis and Periodic Safety Update Report Establishment Method for the Single Use Medical Device - Focusing on Medical Device Regulation 2017/745 requirements (일회용 의료기기에 적용을 위한 ISO 14971:2019 분석과 Periodic Safety Update Report 작성 방법 - Medical Device Regulation 2017/745 요구사항 중심으로)

  • Sang Min, Park;Gyu Ha, Ryu
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • With the announcement of MEDICAL DEVICE REGULATION 2017/745 (MDR) on April 5 2017, medical device manufacturers shall apply ISO 14971:2019 (3rd) revised in December 2019. However, there is not much related information and guidance available to medical device manufacturers, especially single use medical device. Risk management process basically follow 5 steps which are Risk Analysis, Risk Evaluation, Risk Control, Evaluation of overall residual risk and post-production activities. The purpose of this study is to provide a guidance of from risk analysis with Failure Mode and Effects Analysis (FMEA) table to overall residual risk evaluation for the single use medical device and to reflect it in a Periodic Safety Update Reports (PSUR) to satisfy with MDR requirements with single use medical device which are widely used and manufactured FDA class 2 or CE class IIb as examples. For this study, single use medical device manufacturer can adopt ISO 14971:2019 in accordance with MDR requirements and it can be extended to the PSUR. But there are still limitations to adopt to the all-single use medical device especially high class, private device and implantable device. So, Competent Authority (CA) shall publish more guidance for the single use medical device.

User Experience Evaluation of Augmented Reality based Guidance Systems for Solving Rubik's Cube using HMD (HMD를 이용한 증강현실 큐브 맞추기 안내 시스템의 사용자 경험 평가)

  • Park, Jaebum;Park, Changhoon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.7
    • /
    • pp.935-944
    • /
    • 2017
  • As augmented reality technology has developed, various augmented reality contents can be seen in real life, and the performance of mobile device is improved, so augmented reality technology can be used even without special device. As a result, a training system, guidance system and a museum art guide system based on augmented reality technology are emerging, and interest in augmented reality is also increasing. However, the existing guidance systems using a single mobile device have limitations in terms of the user experience (UX) because the camera of the device limits the field of view or the two hands are not free and the user input is difficult. In this paper, we compare augmented reality based guidance systems for Rubik's Cube using tablet and HMD to improve the constraint of user experience of such a single mobile device, and find elements that positively improve user experience. After that, we evaluate whether the user experience is actually improved through the user experience comparison test and the questionnaire.

Development of Basic Techniques for Ultrasound-guided Follicular Aspiration II. Anesthesic Methods and Development of a Disposable Simplified Needle Guidance System for Ovum Pick-up (초음파유도 난포란 채취를 위한 기본 기술의 개발 II. 소의 마취방법과 채란기구의 개발)

  • 최민철;조성근;강태영;박준규;손우진;이효종
    • Journal of Embryo Transfer
    • /
    • v.12 no.2
    • /
    • pp.211-218
    • /
    • 1997
  • This experiment was carried out to develop the anesthetic methods for ultrasonography and a new simplified disposable needle guidance device for ovum pick-up(OPU) in cows. Three different anesthetic methods were applied as. 1) epidural analgesia only with 2% lidocaine(20~30 ml), 2) epidural analgesia with 2% under general sedation with xylazine, 3) epidural analgesia with 2% lidocaine under general sedation with detomidine. We evaluated the anesthetic effects with items such as relaxation of anal sphincter, tail movement and rectal wall, retractability of both ovaries, additional anesthesia and possibility of OPU. Through this experiment, the above three anesthetic methods were applicable to OPU, but the epidural anlagesia under general sedation with detomldine was most effective for OPU. We developed a new disposable needle guidance device with stainless steel tube. With this, disposable needles can be easily attatchable to any other intravaginal probes. And also, it was found to he practical, economic and effective for OPU with the recovery rate of 51.2%.

  • PDF

A System with Efficient Managing and Monitoring for Guidance Device (보행안내 기기의 효과적인 관리 및 모니터링을 위한 시스템)

  • Lee, Jin-Hee;Lee, Eun-Seok;Shin, Byeong-Seok
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.4
    • /
    • pp.187-194
    • /
    • 2016
  • When performing experiments in indoor and outdoor environment, we need a system that monitors a volunteer to prevent dangerous situations and efficiently manages the data in real time. We developed a guidance device for visually impaired person that guides the user to walk safely to the destination in the previous study. We set a POI (Point of Interest) of a specific location indoors and outdoors and tracks the user's position and navigate the walking path using artificial markers and ZigBee modules as landmark. In addition, we develop path finding algorithm to be used for navigation in the guidance device. In the test bed, the volunteers are exposed to dangerous situations and can be an accident due to malfunction of the device since they are visually impaired person or normal person wearing a eye patch. Therefore the device requires a system that remotely monitors the volunteer wearing guidance device and manages indoor or outdoor a lot of map data. In this paper, we introduce a managing system that monitors the volunteers remotely and handles map data efficiently. We implement a management system which can monitor the volunteer in order to prevent a hazardous situation and effectively manage large amounts of data. In addition, we verified the effectiveness of the proposed system through various experiments.

Guidance system about closure using push notification of smart device (스마트 기기의 푸시 알림을 이용한 휴무 안내 시스템)

  • Chung, Myoungbeom
    • Journal of Internet Computing and Services
    • /
    • v.23 no.2
    • /
    • pp.19-28
    • /
    • 2022
  • In this paper, we propose an guidance system about closure using push notification of smart device. Restaurant operators can use the proposed application to schedule and modify the restaurant closures for a week from push notification and users can check the restaurant information and whether it is closed or not through the proposed application. The proposed method uses a server system to provide closed information, and the proposed application performs push notifications to the restaurant operator every morning to confirm the day's closed again. To verify the utility of the proposed system, we built a closure management application, user application, and server system to conduct experiments for restaurant closures guidance, resulting in 96% about checking opening hours. And we confirmed that the proposed method is better than the existing information service in comparison experiments. Thus, the proposed method will be a useful service system that could easily share closure information with restaurant operators and users.

A Study of Fire Shunt Guidance Based on Wireless Sensor Networks (무선 센서 네트워크 기반의 화재 대피 유도 연구)

  • Kim, Yong-Woo;Kim, Do-Hyeon;Kwak, Ho-Young;Park, Hee-Dong
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.11
    • /
    • pp.1547-1554
    • /
    • 2008
  • This paper proposes a fire shunt guidance system model based on rule, it presents suitable shunt route in real-time according to collected fire information of the building inside using wireless sensor networks. So, this system model is composed of the sensor alert module, the behavior suggestion module, and the emergency device control module. The sensor alert module uses rule-base algorithm that monitored the information to collect periodically in wireless sensor networks. And, the behavior suggestion module proposed a suitable behavior, this module supports to judge the fire area with danger sensor list. Additional, the emergency device control module controls a related emergency device according to the suggested behavior and to present on a control screen. We experiment the fire shunt guidance system based on Internet Web for operation verification of the proposed system. Consequently, this study supports people safety with the behavior suggestion according to the context information when an emergency situation happens.

  • PDF

Correct Posture Guidance System using 3-axis Acceleration Sensor for Scoliosis Patient (3축 가속도 센서를 이용한 자세 교정 유도 시스템)

  • An, Yang-Soo;Kim, Keo-Sik;Seo, Jeong-Hwan;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.220-224
    • /
    • 2010
  • In this study, we designed a device for consecutively observing position, utilizing 3-axises acceleration sensor. This method offer to check his or her wrong position and developed could to help derived a position appliance. And, we developed a Cobb's angle value in three dimensional using 3-axises acceleration sensor. A proposed device with integrated accelerometers, which can detect postural changes in terms of curvature variation of the spine in the sagittal and coronal planes, has been developed with intention to facilitate posture training. The proposed device was evaluated with 3 normal subjects daily activities. We evaluated the performance of our designed device as calculating the correlation coefficients and mean errors between the angle measured by an electro-goniometer and that estimated by a gravity accelerometer and verified the accuracy and sensitivity. The results showed that the angle obtained from the proposed device revealed a linear characteristic at the range of $\pm60^{\circ}$(correlation coefficient 0.99, error range $\pm2^{\circ}$). We demonstrated that our device could detect the changes of the motion in upper trunk accurately. Also, our device showed good potential for treatment of the patients with scoliosis and prevention of the unbalance position during a daily life.

Robotic Guidance of Distal Screwing for Intramedullary Nailing Using Optical Tracking System (광학식측정장치를 이용한 금속정 내고정 수술의 원위부 나사체결을 위한 로보틱 유도 시스템)

  • An, Liming;Kim, Woo Young;Ko, Seong Young
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.4
    • /
    • pp.411-418
    • /
    • 2017
  • During the intramedullary nailing procedure, surgeons feel difficulty in manipulation of the X-ray device to align it to axes of nailing holes and suffer from the large radiation exposure from the X-ray device. These problems are caused by the fact the surgeon cannot see the hole's location directly and should use the X-ray device to find the hole's location and direction. In this paper, we proposed the robotic guidance of the distal screwing using an optical tracking system. To track the location of the hole for the distal screwing, the reference marker is attached to the proximal end of an intramedullary nail. To guide the drill's direction robustly, the 6-degree-of-freedom robotic arm is used. The robotic arm is controlled so as to align the drill guiding tool attached the robotic arm with the obtained the hole's location. For the safety, the robot's linear and angular velocities are restricted to the predefined values. The experimental results using the artificial bones showed that the position error and the orientation error were 0.91 mm and $1.64^{\circ}$, respectively. The proposed method is simple and easy to implement, thus it is expected to be adopted easily while reducing the radiation exposure significantly.