수직으로 설치된 비균질 평판 단열재용 성능시험장치 개발 (Development of Thermal Performance Tester for Non-Homogeneous Insulation Pannels Installed Vertically)

  • 오홍영;송기오;전현익;조선영
    • 설비공학논문집
    • /
    • 제28권4호
    • /
    • pp.153-157
    • /
    • 2016
  • In case of metal insulation, which is produced by stacking stainless steel sheets and air layers in a multi-stack manner at a specific thickness, insulation performance will be evaluated based on thermal transmittance rather than the intrinsic physical properties of each material such as thermal conductivity. However, there is no standard for measuring thermal transmittance targeted for non-homogeneous insulation which is used in relatively high temperature conditions such as a power station. In this study, the thermal conductivity of homogeneous insulation acquired by the standardized guard hot plate method and the thermal conductivity of homogeneous insulation measured by the newly developed performance tester were compared to verify the confidence level of the tester. As a result, thermal conductivity acquired by the newly developed thermal transmittance tester was about 6% higher than the thermal conductivity measured by the existing guard hot plate method under the anticipated service temperature conditions.

실험적 열적 물성치를 반영한 CCS 방열박스의 열전달 해석 (Thermal analysis of two main CCS(cargo containment system) insultaion box by using experimental thermal properties)

  • 최성웅;노정우;김무선;이우일
    • 한국전산구조공학회논문집
    • /
    • 제24권4호
    • /
    • pp.429-438
    • /
    • 2011
  • 본 논문에서는 Membrane형 LNG선의 구성 요소를 대상으로 단열창의 열적 분포를 알아보기 위해 극저온 상태에서부터 온도 별로 각 소재의 열적 물성치인 열전도도(thermal conductivity)를 실험을 통해서 알아보았다. 극저온 상태인 $-163^{\circ}C$의 온도상태로 유지되어야 하는 LNG선 화물탱크는 단열재료로 하여금 열을 차단하기 위해 많은 연구가 되어야 하는데 특히 여러 재료로 구성되어 있는 단열 화물창(CCS: Cargo containment system)은 열적 물성치가 온도에 따라 각각 어떠한 값을 가지는 것이 주요 관심대상이고, 이를 통해 전체 LNG 단열 화물창이 어떤 열적 분포를 가지는 것에 대한 연구가 필요하다. 실험을 통해 얻은 물성치를 가지고 전체 화물창의 온도분포를 정적 열해석을 통해 알아보았다. 또한 외부의 충격에 의해 LNG가 누수되었을때 2차 방벽 특히 hull 부분에서는 누수량에 대해서 어떠한 온도분포와 열적 안전성에 대해서 알아보았다.

가속노화 시험을 통한 진공단열패널(VIP)의 장기성능 평가 연구 (The Study of Long-Term Performance Evaluation of Vacuum Insulation Panel(VIP) with Accelerated Aging Test)

  • 김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제37권4호
    • /
    • pp.35-47
    • /
    • 2017
  • Energy efficiency solutions are being pursued as a sustainable approach to reducing energy consumption and related gas emissions across various sectors of the economy. Vacuum Insulation Panel (VIP) is an energy efficient advanced insulation system that facilitates slim but high-performance insulation, based on a porous core material evacuated and encapsulated in a barrier envelope. Although VIP has been applied in buildings for over a decade, it wasn't until recently that efforts have been initiated to propose and adopt a global standard on characterization and testing of VIP. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time; more so in building applications. In this paper, the aging of commercially available VIP was investigated experimentally; thermal conductivity was tested in accordance with ISO 8302 standard (guarded hot box method) and long-term durability was estimated based on a non-linear pressure-humidity dependent equation based on study of IEA/ECBCS Annex 39, with the aim of assessing durability of VIP for use in buildings. The center-of-panel thermal conductivity after 25 years based on initial 90% fractile with a confidence level of 90 % for the thermal conductivity (${\lambda}90/90$) ranged from 0.00726-0.00814 (W/m K) for silica core VIP. Significant differences between manufacturer-provided data and measurements of thermal conductivity and internal pressure were observed.