• Title/Summary/Keyword: Grouting type waterproofing method

Search Result 3, Processing Time 0.019 seconds

A Study on the Waterproofing Performance of Waterproofing Methods for PHC-W Earth Retaining Wall Based on Pressure Chamber Test (PHC-W 흙막이 공법의 차수방안에 관한 차수성능확인을 위한 모형 압력 수조 실험 연구)

  • Choi, Yongkyu;Johannes, Jeanette Odelia;Yun, Daehee;Kim, Chae min;Jeon, Byeong Han
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.12
    • /
    • pp.115-125
    • /
    • 2017
  • PHC-W earth retaining wall could be constructed continuously. Various retaining wall methods such as C.I.P. etc. method require separate waterproof method. However, the PHC-W retaining wall method prevents leakage of groundwater by inserting a waterproofing material at connection part between 2 PHC piles. In this study, the experimental study on 3 waterproofing method for PHC-W retaining wall was conducted at the model pressure chamber. In the method using textile with 1-liquid type and 2-liquid type urethane, rapid leak occurred at the pressure of 120 kPa and 140 kPa or more. In the method of textile with grouting, rapid leak occurred at the pressure of 120 kPa or more, however, in this method, the rapid leakage happened at the top part and the bottom part reinforced with urethane.

A Case Studty on the Ground Reinforcement and Waterproofing Effect of Weathering and Fault Zone by Special Injection Tip Equipment Using Microcement Type (특수주입선단장치에 의한 마이크로시멘트계 약액주입의 풍화대, 단층파쇄대의 지반보강 및 차수효과 사례연구)

  • Do, Jongnam;Jung, Jongju;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.2
    • /
    • pp.21-28
    • /
    • 2009
  • A grouting method has been widely used in construction of large-scale structure to reduce permeability and reinforce the ground. If cement and grout material were not mixed well in the injection tip equipment, an opposite flow and interception state of the chemical grouting can occur. McG (Multi-mixing counterflow prevented Grouting, McG) method installed a special grouting device to allow better mixing of the grouting material(above fineness $6,000cm^2/g$) and prevent backward flow. The block of nozzle also diversify powder rate of cement. YSS (Youngil Special Silicate, YSS) that lowers $Na_2O$ and thereby increases durability was developed by gel-forming reaction material. The seepage state and unconfined compressive strength of the injection material using the special injection tip equipment was tested in this study. The results of this study showed that the uniaxial compressive strength, permeability, N-value, TCR and RQD were improved by this method. Engineering characteristics obtained by the special injection tip method will be compared with those by the other method through various field tests from now on.

  • PDF

Evaluation of field applicability for grouting method using self-healing grout material (자기치유 물질을 이용한 그라우팅공법의 현장적용성 평가)

  • Choi, Yong-Sung;Kim, Byoung-Il;Yoo, Wan-Kyu;Lee, Jae-Dug;Choi, Yong-Ki
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.5
    • /
    • pp.485-500
    • /
    • 2020
  • Due to various advantages such as small facilities, ease of construction and so on, the grouting technology which is widely used in construction field has developed remarkably compared with the past. However, the efforts to improve the homogeneity of quality, long-term durability and environmental problems have been continued. In recent years, new grouting method has been developed in order to solve problems such as low strength, durability and leaching phenomenon of liquid glass (sodium silicate) grouting material in Korea. A newly developed method integrates the injection material with the ground by the self-healing material of crystallization growth type. For this reason, it is known that improvement of the durability and water quality of the ground, prevention of leaching, and environment friendliness can be expected. The present study applied a newly developed method to test sites and verified its effect such as injection range, improvement effect, waterproofing performance and so on. Standard penetration test, field permeability test, borehole shear test, pressuremeter test and pH test were conducted, and the results were compared between before and after developed method application. As results of tests, the field applicability and improvement effect of developed method were proved to be excellent.