• Title/Summary/Keyword: Group testing

Search Result 1,777, Processing Time 0.037 seconds

Biomechanical Testing of Anterior Cervical Spine Implants: Evaluation of Changes in Strength Characteristics and Metal Fatigue Resulting from Minimal Bending and Cyclic Loading

  • Kim, Sung-Bum;Bak, Koang-Hum;Cheong, Jin-Hwan;Kim, Jae-Min;Kim, Choong-Hyun;Oh, Seong-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.217-222
    • /
    • 2005
  • Objective: To achieve optimal fit of implant, it is necessary to bend the implant during spine surgery. Bending procedure may decrease stiffness of plate especially made of titanium and stainless steel. Typically titanium suffers adverse effects including early crack propagation when it is bent. We investigate whether 6 degree bending of titanium plates would decrease the stiffness after full cyclic loading by comparing with non-bending titanium plates group. Methods: Authors experimented 40 titanium alloy plates of 57mm in length, manufactured by 5 different companies. Total 40 plates were divided into two groups (20 bent plates for experimental group and 20 non-bent plates for control group). Twenty plates of experimental group were bent to 6 degree with 3-point bending technique and verified with image analyzer. Using the electron microscope, we sought for a initial crack before and after 3-point bending. Mechanical testing by means of 6000 cyclic axial-compression loading of 35N in compression with moment arm of 35mm-1.1 Nm was conducted on each plate and followed by the electron microscopic examination to detect crack or fissure on plates. Results: The stiffness was decreased after 6000 cyclic loading, but there was no statistically significant difference in stiffness between experimental and control group. There was no evidence of change in grain structure on the electron microscopic magnification. Conclusion: The titanium cervical plates can be bent to 6 degree without any crack or weakness of plate. We also assume that minimal bending may increase the resistance to fatigue fracture in cervical flexion-extension movement.

MTF and wavefront error testing of large aperture optical system using unequal path interferometer (경로길이 불일치 간섭계를 이용한 대구경 광학계의 MTF 측정과 파면오차 검사)

  • Song, Jong-Sup;Jo, Jae-Heung;Lee, Yun-Woo;Song, Jae-Bong;Yang, Ho-Soon;Lee, In-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.50-55
    • /
    • 2005
  • A method for measuring the wavefront error and the modulation transfer function(MTF) of large aperture optics using an unequal path interferometer is presented. A bidirectional shearing interferometer is used for collimation testing of the measurement system. A large aperture Fizeau interferometer with long optical path difference measures the wavefront error of the optics under test by using a $\Phi$ 400 mm off-axis parabolic mirror. The MTF is also measured at the wavelength of the interferometer by changing the laser light into partially incoherent light. Test results of a $\Phi$ 300 mm Cassegrain type satellite telescope made in Korea are presented.

Effect of Knee Stabilization Exercise on Balance and Walking Ability in Patients with Total Knee Replacement (무릎관절 전치환술 환자에게 적용한 무릎 안정화 운동이 균형과 보행능력에 미치는 영향)

  • Park, Geun-hong;Kim, Tae-won;Song, Hyoung-bong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.27 no.2
    • /
    • pp.69-76
    • /
    • 2021
  • Background: Degenerative arthritis accounts for a large portion of the elderly, causing a lot of inconvenience in daily life. Total knee replacement (TKR) are performed to relieve pain in the knee joint. The purpose of this study was to determine whether knee joint stabilization exercises are effective in improving balance and walking ability in degenerative arthritis patients who have undergone TKR. Methods: A total of 30 TKR patients participated in this study. They were assigned to two groups. The experimental group, the group that underwent knee stabilization exercises, joint mobilization and general physical therapy. On the other hand, and the controlled group, the group that underwent joint mobilization and general physical therapy. All exercises were conducted thrice a week, for four weeks. The main balance outcomes were evaluated using the posture balance training system, while walking ability was assessed using a wireless 3-axis accelerometer. Results: The experimental group had significantly higher scores in postural stability testing (PST), limits stability testing, and waling ability. The post-intervention evaluation, there were significant differences in all variables between the two groups. However, no significant difference was noted in the foam eyes closed test in PST. Conclusion: This study suggests that knee joint stabilization exercises effectively improve the balance and walking ability of TKR patients. Thus, it could be presented as useful in clinical practice.

Clinical Features of the Persistent Idiopathic Dentoalveolar Pain Compared with Inflammatory Dental Pain

  • Jang, Ji Hee;Chung, Jin Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.47 no.2
    • /
    • pp.87-94
    • /
    • 2022
  • Purpose: This study aimed to evaluate the differences between clinical and quantitative sensory testing (QST) results among persistent idiopathic dentoalveolar pain (PIDP), inflammatory dental pain, and control group subjects to identify discriminative clinical features for differential diagnosis. Methods: Thirty-three patients (5 PIDP-a without surgical procedures 10 PIDP-b with surgical procedures, 8 dental pain patients, and 10 controls) were evaluated for clinical features and QST results. Cold pain threshold, heat pain threshold, mechanical pain threshold (MPT), mechanical pain sensitivity, and pressure pain threshold (PPT) were performed. Psychological factors were assessed using Symptom Checklist-90-Revision (SCL-90-R) and a chart review was conducted to evaluate additional discriminative clinical features such as pain quality and treatment prognosis. Results: The dental pain group had lower PPT than the PIDP-b and the control group. The PIDP-a group showed higher MPT and PPT than the PIDP-b and dental pain group but the difference was not statistically significant. Differences in SCL-90-R SOM (Somatization), O-C (obsessive-compulsive), ANX (anxiety), and PSY (Psychoticism) values were statistically significant among groups. PIDP-a and PIDP-b groups showed remaining symptoms after treatment and the pain tended to spread widely, whereas, in toothache patients, symptoms disappeared after treatment. However, factors that confound the diagnosis, such as an increase in pain during chewing and a decrease in the pain threshold at the affected site, could also be identified. Conclusions: PIDP and dental pain groups have distinct clinical symptoms, but there are also factors that cause confusing in diagnosis. Therefore, various clinical examination results should be carefully reviewed and comprehensively evaluated in the differential diagnosis process.

Novel Three-Dimensional Knitted Fabric for Pressure Ulcer Prevention: Preliminary Clinical Application and Testing in a Diabetic Mouse Model of Pressure Ulcers

  • Kim, Sungae;Hong, Jamin;Lee, Yongseong;Son, Daegu
    • Archives of Plastic Surgery
    • /
    • v.49 no.2
    • /
    • pp.275-284
    • /
    • 2022
  • Background Population aging has led to an increased incidence of pressure ulcers, resulting in a social burden and economic costs. We developed a three-dimensional knitted fabric (3-DKF) with a pressure-reducing function that can be applied topically in the early stages of pressure ulcers to prevent progression. Methods We evaluated the effects of the 3-DKF in a streptozotocin-induced diabetes mellitus pressure ulcer mouse model, and the fabric was preliminarily applied to patients. Twelve-week-old male C57BL/6 mice were used for the animal experiments. In the pressure ulcer mouse model, an ischemia-reperfusion injury was created using a magnet on the dorsa of the mice. Pressure was measured with BodiTrak before and after applying the 3-DKF to 14 patients at risk of sacral pressure ulcers. Results In the 3-DKF-applied mice group, the ulcers were shallower and smaller than those in the control group. Compared with the mice in the control group, the 3-DKF group had lower platelet-derived growth factor-α and neutrophil elastase expression, as parameters related to inflammation, and increased levels of transforming growth factor (TGF)-β1, TGF-β3, proliferating cell nuclear antigen, and α-smooth muscle actin, which are related to growth factors and proliferation. Additionally, typical normal tissue staining patterns were observed in the 3-DKF group. In the preliminary clinical analysis, the average skin pressure was 26.2 mm Hg before applying the 3-DKF, but it decreased to an average of 23.4 mm Hg after 3-DKF application. Conclusion This study demonstrated that the newly developed 3-DKF was effective in preventing pressure ulcers through testing in a pressure ulcer animal model and preliminary clinical application.

A Computerized Testing system that Reduces Backward Reasoning in Multiple-choice Items (선다형 문항에서 역행추리를 줄이는 컴퓨터화 검사 방식)

  • Park, Joo-Yong
    • Korean Journal of Cognitive Science
    • /
    • v.20 no.3
    • /
    • pp.275-289
    • /
    • 2009
  • A new computerized testing system, called the Computerized Multiple-choice Testing (CMMT) system, was introduced. In this system, questions of multiple choice (MC) items are presented first without options, so that students must generate answers for themselves. They can click for the options when they are ready, and can respond within a brief, specified time period. The present study was performed to examine whether this system is effective in reducing backward reasoning, I. e., using the options of MC items as cues to find the correct answer. One hundred and seventy-seven 6th grade students (12 year olds) were divided into two groups so that mean scores from a prior test were equal: The experimental group took an intervening computerized test in the new format, and the control group in the MC format. Five days after the computerized intervening test, a short answer paper-and-pencil final test was given. Testing effect was greater in the new system than in the MC system. Analysis of the final test response in relation to the intervening test response showed that i) the students retained the correct answer in the new system more than in the MC testing system, and that ii) students corrected their previous failures in the intervening CMMT format more than those in the MC format. These results suggest that the new system is effective in reducing backward reasoning.

  • PDF

Thickness Evaluation of the Aluminum Using Pulsed Eddy Current (펄스 와전류를 이용한 알루미늄 두께 평가)

  • Lee, Jeong-Ki;Suh, Dong-Man;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.15-19
    • /
    • 2005
  • Conventional eddy current testing has been used for the detection of the defect-like fatigue crack in the conductive materials, such as aluminum, which uses a sinusoidal signal with very narrow frequency bandwidth, Whereas, the pulsed eddy current method uses a pulse signal with a broad bandwidth. This can allow multi-frequency eddy current testing, and the penetration depth is greater than that of the conventional eddy current testing. In this work, a pulsed eddy current instrument was developed for evaluating the metal loss. The developed instrument was composed of the pulse generator generating the maximum square pulse voltage of 40V, an amplifier controlled up to 52dB, an A/D converter of 16 bit and the sampling frequency of 20 MHz, and an industrial personal computer operated by the Windows program. A pulsed eddy current probe was designed as a pancake type in which the sensing roil was located inside the driving roil. The output signals of the sensing roil increased rapidly wich the step pulse driving voltage かn off, and the latter part of the sensing coil output voltage decreased exponentially with time. The decrement value of the output signals increased as the thickness of the aluminum test piece increased.

The effect of contamination of the etched matal retainer on resin bonding strength (금속 유지장치의 오염이 레진 접착 결합력에 미치는 영향)

  • Park, Ha-Ok;Bang, Mong-Sook
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.217-224
    • /
    • 2002
  • The purpose of this study was to evaluate the influence of saliva contamination on the resin bonding of the etched metal retainers. The test samples were made of Verabond, and divided into 3 groups. Retainers in group1 had normally etched metal surfaces. Retainers in group2 had normally etched metal surfaces which were saliva-contaminated for 30 seconds and cleaned with streaming, luke-warm for 1 minute and dried thoroughly. Retainers in group3 had normally etched metal surfaces which were saliva- contaminated for 30 seconds and dried thoroughly without water-cleansing. Each 3 group specimen was watched on SEM. A resin core, 5mm in diameter and 6mm in length, was made of Panavia using Teflon mold on the each specimen. These 3 groups were tested to evaluate shear bond strength, using universal testing machine. The results were as follows : 1. The shear bond strength showed no significant difference between group1 and group2. 2. The shear bond strength showed significant difference between group1 and group3. 3. The shear bond strength significant difference between group2 and group3. 4. Scanning electron microscope photographs of group1 and group2 showed no signs of contamination but of group3 showed somewhat contaminated.

MICROSHEAR BOND STRENGTH OF ADHESIVES ACCORDING TO THE DIRECTION OF ENAMEL RODS (법랑소주 방향에 따른 접착제의 미세전단 결합강도)

  • Cho, Young-Gon;Kim, Jong-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.344-351
    • /
    • 2005
  • This study compared the microshear bond strength $({\mu}SBS)$ to end and side of enamel rod bonded by four adhesives including two total etch adhesives and two self-etch adhesives. Crown segments of extracted human molars were cut mesiodistally. The outer buccal or lingual surface was used as specimens cutting the ends of enamel rods, and inner slabs used as specimens cutting the sides of enamel rods. They were assigned to four groups by used adhesives: Group 1 (All-Bond 2), Group 2 (Single Bond), Group 3 (Tyrian SPE/One-Step Plus), Group 4 (Adper Prompt L-Pop). After each adhesive was applied to enamel surface, three composite cylinders were adhered to it of each specimen using Tygon tube. After storage in distilled water for 24 hours, the bonded specimens were subjected to ${\mu}SBS$ testing with a crosshead speed of 1 mm/minute. The results of this study were as follows: 1. The $({\mu}SBS)$ of Group 2 $(16.50\pm2.31 MPa)$ and Group 4 $(15.83\pm2.33 MPa)$ to the end of enamel prism was significantly higher than that of Group 1 $(11.93\pm2.25 MPa)$ and Group 3 $(11.97\pm2.05 MPa)$ (p<0.05). 2. The $({\mu}SBS)$ of Group 2 $(13.43\pm2.93 MPa)$ to the side of enamel prism was significantly higher than that of Group 1 $(8.64\pm1.53 MPa)$, Group 3 $(9.69\pm1.80 MPa)$, and Group 4 $(10.56 \pm1.75 MPa)$ (p<0.05), 3. The mean $({\mu}SBS)$ to the end of enamel rod was significantly higher than that to the side of enamel rod in all group (p<0.05).

On-Line Partial Discharge Detecting Method for Insulation Diagnosis of High-Voltage Motor Stator Windings (고압 전동기 고정자 권선의 절연진단을 위한 운전중 부분방전 측정기법)

  • Hwang, D.H.;Shin, B.C.;Sim, W.Y.;Park, D.Y.;Kim, Y.J.;Song, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1727-1729
    • /
    • 2001
  • Partial discharge testing are rapidly becoming the most powerful tool to assess the condition of high voltage generator and motor stator windings. Recently, on-line monitoring scheme with trending technique is widely applied in insulation diagnosis. This paper describes the on-line partial discharge detecting techniques in the high voltage motor stator windings. Also, on-line monitoring system for an insulation diagnosis are proposed.

  • PDF