• 제목/요약/키워드: Groundwater system

검색결과 1,184건 처리시간 0.024초

지하수관리체계 개선방안에 관한 연구 (A Study on the Strategies for the Improvement of Groundwater Management System)

  • 김상권
    • 대한지하수환경학회지
    • /
    • 제7권1호
    • /
    • pp.47-54
    • /
    • 2000
  • 우리나라의 지하수이용량은 전체 수자원이용량에서 상당부분을 차지하고 있고 이용량이 최근 몇 년간 급격히 증가하고 있다. 그러나 관리체계가 제대로 구축되어 있지 않아 난개발 및 수질오염 등 여러 가지 문제점이 있어 이러한 문제점을 해소하고 지하수를 체계적으로 관리할 수 있도록 개선방안을 제시하였다.

  • PDF

Evaluation of waste disposal site using the DRASTIC system in Southern Korea

  • Lee, S.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.126-128
    • /
    • 2003
  • As a systematic approach to waste disposal site screening for groundwater pollution protection, the DRASTIC system developed by the US Environmental Protection Agency (USEPA) was introduced at Younggwang County in Korea. Hydrogeologic spatial databases for the system include info rmation on depth to water, net recharge, aquifer media, soil media, topographic slope, hydraulic conductivity and lineament. Using the databases, the DRASTIC system and a GIS, the regional groundwater pollution vulnerability of the study area was assessed. The fracture density extracted from lineament maps was added to the DRASTIC system to take into account the preferential migration of contaminants through fractures. From the results of the study, a degree of groundwater pollution vulnerability through the study area was easily interpreted, and waste disposal sites could be screened for groundwater protection.

  • PDF

국내 지하수 통합관리 선진화 전략 (The Strategy for the Advancement of Groundwater Management in Korea)

  • 강성구;김지욱;최용준;박민영;박현진;이진관
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제27권2호
    • /
    • pp.36-40
    • /
    • 2022
  • To respond to rapidly changing water circumstances such as climate change, drought, etc., the korean government (MOE) established four advanced strategies for integrated groundwater management. The first strategy is watershed-based management of groundwater. The second strategy is total quantity management of groundwater including improvement of groundwater preservation area policy and procedure of investigation for groundwater influence area, additional construction of groundwater dam, installation of large-scale public wells, extention of spilled groundwater use. The third strategy is prevention of groundwater contamination including expansion of monitoring wells, introducing declaration of groundwater contamination. The last strategy is advancement of groundwater information management including integrated management of data, setting up a big-data based open platform. The above-mentioned four strategies will be reflected in the 4th National Groundwater Management Plan to secure implementation power, and it is expected to laid the foundation for advanced and rational groundwater management system.

지하수 히트펌프 시스템의 대수층 활용 사레 연구 (Study on the aquifer utilization for a ground water heat pump system)

  • 심병완;이철우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF

지하수 오염복원에서 현장규모 이방성의 효과 (Effects of Site-scale Anisotropy of an Aquifer on Groundwater Remediation)

  • 이재민;이병선;우남칠
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권6호
    • /
    • pp.17-28
    • /
    • 2010
  • As a preliminary survey to improve efficiency of well-based permeable reactive barrier system for groundwater remediation, this site-scale study was carried to identify the flowpaths and controlling factors of plume at a remediation site in Suwon City, Korea. A total of 22 monitoring wells were installed as a grid system in the $4m{\times}4m$ square area by 1-m interval. For the groundwater characterization, various tests were performed including water-level monitoring, water sampling & analysis, pumping and slug tests, and tracer tests. The aquifer appeared to be unconfined with hydraulic conductivities (K) ranging from $2.6{\times}10^{-4}cm/s$ to $9.5{\times}10^{-3}cm/s$. The average linear velocity of groundwater was estimated to be $2.94{\times}10^{-6}m/s$, and the longitudinal dispersivity of a conservative tracer to be $5.94{\times}10^{-7}m^2/s$. Groundwater plume moves preferentially through the high-K zones, and the relatively high ion concentrations along the low-K zones implying deterred groundwater flow. Consequently, the spatial variation of hydraulic conductivity caused by aquifer heterogeneity and anisotropy appears to be the most important factor to maximize the effect of plume treatment system for application of in-situ groundwater remediation techniques.

지하수류가 밀폐형 천공 지중 열교환기 성능에 미치는 영향(2) (An Influence of Groundwater Flow on Performance of Closed Borehole Heat Exchangers (Part-2))

  • 한정상;김영식;이주현;이병호;한찬
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권6호
    • /
    • pp.114-127
    • /
    • 2016
  • An increase of groundwater flux in BHE system creates that ground temperature (locT) becomes lower in summer and higher in winter time. In other words, it improves significantly the performance of BHE system. The size of thermal plume made up by advection driven-flow under the balanced energy load is relatively small in contrast to the unbalanced energy load where groundwater flow causes considerable change in the size of thermal plume as well ground temperature. The ground temperatures of the up gradient and down gradient BHEs under conduction only heat transport are same due to no groundwater flow. But a significant difference of the ground temperature is observed between the down gradient and up gradient BHE as a result of groundwater flow-driven thermal interference took placed in BHE field. As many BHEs are designed under the obscure assumption of negligible groundwater flow, failure to account for advection can cause inefficiencies in system design and operation. Therefore including groundwater flow in the design procedure is considered to be essential for thermal and economic sustain ability of the BHE system.

지하수류가 대수층 열저장 시스템의 성능에 미치는 영향(3) (The Influence of Groundwater Flow on the Performance of an Aquifer Thermal Energy Storage (ATES) System)

  • 한정상;이주현;김영식;이광진;홍경식
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권4호
    • /
    • pp.9-26
    • /
    • 2017
  • When a warm well located downgradient is captured by cold thermal plume originated from an upgradient cold well, the warm thermal plume is pushed further downgradient in the direction of groundwater flow. If groundwater flow direction is parallel to an aquifer thermal energy storage (ATES), the warm well can no longer be utilized as a heat source during the winter season because of the reduced heat capacity of the warm groundwater. It has been found that when the specific discharge is increased by $1{\times}10^{-7}m/s$ in this situation, the performance of ATES is decreased by approximately 2.9% in the warm thermal plume, and approximately 6.5% in the cold thermal plume. An increase of the specific discharge in a permeable hydrogeothermal system with a relatively large hydraulic gradient creates serious thermal interferences between warm and cold thermal plumes. Therefore, an area comprising a permeable aquifer system with large hydraulic gradient should not be used for ATES site. In case of ATES located perpendicular to groundwater flow, when the specific discharge is increased by $1{\times}10^{-7}m/s$ in the warm thermal plume, the performance of ATES is decreased by about 2.5%. This is 13.8% less reduced performance than the parallel case, indicating that an increase of groundwater flow tends to decrease the thermal interference between cold and warm wells. The system performance of ATES that is perpendicular to groundwater flow is much better than that of parallel ATES.

WINFLOW 모델을 이용한 지하수 유동해석 (Groundwater Movement Analysis Using the WINFLOW Model)

  • 최윤영;안승섭;김재광
    • 한국농공학회지
    • /
    • 제45권3호
    • /
    • pp.103-115
    • /
    • 2003
  • This study examines groundwater movement system analysis and movement forecast algorithm using finite element method. The target is Cheongha-myeon area, Bukgu, Pohang-city which has many difficulties in water supply during drought period. From the comparison of the differences between obtained values by WINFlOW model and observed values, it is thought that groundwater head distribution under steady flow is reflected well at the level of reliability Groundwater movement of study area shows stable pattern from western watershed to eastern coastal area while flow path is dense and steep in the center of the coastal area. The results of particle tracing for each well show a comparatively straight line from the western boundary side to the observation position at the upper area of the well, and are analyzed as it diffuses according to getting closer to the coast at the lower area of the well. The result of effect circle examination attendant on pumping amount in study area shows variation tendency that groundwater head decreases at the side and the lower area more than at the upper area of the well when groundwater flows from west to east(coast). As mentioned above, satisfactory results of groundwater movement analysis using WINFlOW model, two dimensional groundwater movement analysis model, are obtained through the great decrease of physical uncertainty of groundwater movement system.

Groundwater Fluxes in a Watershed with a Lake

  • Bae, Sang-Keun
    • Korean Journal of Hydrosciences
    • /
    • 제7권
    • /
    • pp.9-19
    • /
    • 1996
  • The purpose of this study is to investigate the influence of the position of lake upon groundwater fluxes on a lake watershed, and to provide for the monitoring network design to survey the exchange relations between groundwater and lake water. Three kinds of hypothetical flow through lakes, which are located at the upper, middle, and lower portion of a watershed were considered. Groundwater flow for each case was numercally simulated under three-dimensional steady state conditions. The exchange rates of the groundwater, the amounts of recharge and discharge, and groundwater fluxes between lake and groundwater in a watershed system with a lake were clarified.

  • PDF

개방형 지열시스템의 효율적 설계를 위한 영향인자에 대한 연구 (A Study on Significant Parameters for Efficient Design of Open-loop Groundwater Heat Pump (GWHP) Systems)

  • 박병학;전원탁;이보현;이강근
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권4호
    • /
    • pp.41-50
    • /
    • 2015
  • Open-loop groundwater heat pump (GWHP) system generally has benefits such as a higher coefficient of performance (COP), lower initial cost, and flexible system size. The hydrogeological conditions in Korea have the potential to facilitate the use of the GWHP system because a large number of monitoring wells show stable groundwater temperatures, shallow water levels, and high well yields. However, few studies have been performed in Korea regarding the GWHP system and the most studies among them dealt with Standing Column Well (SCW). Because the properties of the aquifer have an influence on designing open-loop systems, it is necessary to perform studies on various hydrogeological settings. In this study, the hydrogeological and thermal properties were estimated through various tests in the riverside alluvial layer where a GWHP system was installed. Under different groundwater flow velocities and pumping and injection rates, a sensitivity analysis was performed to evaluate the effect of such properties on the design of open-loop systems. The results showed that hydraulic conductivity and thermal dispersivity of the aquifer are the most sensitive parameters in terms of performance and environmental aspects, and sensitivities of the properties depend on conditions.