• Title/Summary/Keyword: Groundwater pumping

Search Result 324, Processing Time 0.021 seconds

The Water Environment at the Seokdae Waste Landfill Area in the Pusan Metropolitan City (부산 석대 폐기물 매립지 일원의 수질 환경)

  • 정상용;권해우;이강근;김윤영
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.4
    • /
    • pp.175-184
    • /
    • 1997
  • The Seokdae Waste Landfill is a middle-sized site used from June, 1987 to May, 1993. Many joints and faults are developed in andesitic rocks and rhyolitic rocks distributed at the landfill. The chemical analyses of leachates, streams and groundwaters sampled in July, 1996 and June, 1997 show that the concentrations of leachates and streams were decreased, and that the groundwater qualities became worse. The groundwater contamination is deeply extended to not only shallow groundwater but also bedrock-groundwater around the Seokdae Waste Landfill Area. The range of groundwater contamination by the leachates is about 500 m to the west and about 1 km to the south from the boundaries of the waste landfill. The development of monitoring wells and pumping wells, the construction of a leachate-treatment facilities, and the adjustment of the existing grout curtains are necessary for the control of water pollution at the Seokdae Waste Landfill Area.

  • PDF

Groundwater Flow Analysis Using Finite Difference Method in Volcanic Island (화산도서에서 유한차분법을 이용한 지하수 유동해석)

  • Choe, Yun-Yeong;Lee, Sun-Tak
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.5
    • /
    • pp.611-622
    • /
    • 2000
  • In this study, MODFLOW model is used to analyze the groundwater flow system of Seoguipo area in Cheju island, The final parameters of permeability coefficient and storage coefficient of target area can be obtained by trial and error method using the measured data of pumping rate as initial values. And it is found that the applicability for groundwater flow system is reflected well from the simulation result of the model. Seoguipo area spring water is thought to appear by relatively stable groundwater recharge below EL. 400m according to head distribution through the analysis of observed data considering topographic and geological characteristics, Lee's study(996), and the simulation result. Also it is known that point II, III, and VI show relatively large velocity vectors, and groundwater flows through the movement path which is distributed in various directions of I, II, III, IV, V, VI, and VIl form the result of velocity vector analysis using head distribution result values to analyze the groundwater flow path under unsteady flow condition.dition.

  • PDF

An Integrated Surface Water-Groundwater Modeling by Using Fully Combined SWAT MODFLOW Model (완전연동형 SWAT-MODFLOW 모형을 이용한 지표수-지하수 통합 유출모의)

  • Kim, Nam Won;Chung, Il Moon;Won, Yoo Seung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5B
    • /
    • pp.481-488
    • /
    • 2006
  • This paper suggests a novel approach of integrating the quasi-distributed watershed model SWAT with the fully-distributed groundwater model MODFLOW. Since the SWAT model has semi distributed features, its groundwater components hardly considers distributed parameters such as hydraulic conductivity and storage coefficient. Generating a detailed representation of groundwater recharge, head distribution and pumping rate is equally difficult. To solve these problems, the method of exchanging the characteristics of the hydrologic response units (HRUs) in SWAT with cells in MODFLOW by fully combined manner is proposed. The linkage is completed by considering the interaction between the stream network and the aquifer to reflect boundary flow. This approach is provisionally applied to Gyungancheon basin in Korea. The application demonstrates a combined model which enables an interaction between saturated zones and channel reaches. This interaction plays an essential role in the runoff generation in the Gyungancheon basin. The comprehensive results show a wide applicability of the model which represents the temporal-spatial groundwater head distribution and recharge.

Analysis of Stream Depletion Rate by Groundwater Abstraction in Leaky Aquifer (누수대수층 지하수 양수에 따른 하천수 감소율 거동 분석)

  • Lee, Jeongwoo;Chung, Il-Moon;Kim, Nam Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.6
    • /
    • pp.1001-1008
    • /
    • 2017
  • This study was to evaluate the stream depletion rate from groundwater pumping with varying stream-well distance, aquifer transmissivity, storage coefficient, leakage coefficient, streambed hydraulic conductance using the Zlotnik and Tartakovsky analytical solution which considers a two-layer leaky aquifer-stream-well system. For the hydraulic conditions applied in this study, the streambed hydraulic conductance and the aquitard leakage coefficient were assessed to have a dominant influence on the stream depletion rate. In order to evaluate the applicability of Zlotnik and Tartakovsky analytical solution ignoring the change in the drawdown in the lower aquifer and applying the fixed head boundary condition, the solution was compared with Hunt analytical solution derived from the more practical conditions simultaneously taking into account the drawdown changes in the upper and lower aquifers. As a result, the Zlotnik and Tartakovsky analytical solution is suitable for predicting short-term effects of less than one year in the pumping period, and when the stream depletion factor (SDF) is greater than 2,500 days, or when the product of the leakage coefficient and the stream-well distance is less than 10 cm/s.

Selecting Aquifer Artificial Recharge Methods Based on Characteristics of the Target Aquifer (주입대상 대수층의 특성을 고려한 인공함양 방법 선정 연구)

  • Lee, Yeoung-Dong;Shin, Dong-Min;Kim, Byeong-Jun;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.483-494
    • /
    • 2019
  • This study aimed to determine the extent of artificial aquifer recharge and to evaluate appropriate recharge techniques based on field investigations and comparative analysis of each recharge method. Characteristics of the aquifer determine the target aquifer and the recharge method for artificial groundwater recharge. Electrical conductivity surveys, drilling, permeability tests, and grain-size analysis indicate that the hydraulic conductivity of weathered soil and weathered rock is higher than that of upper unconsolidated soil. Pumping tests indicate that the groundwater level was stable at a depth of 12 m until 9 hours of pumping, but after that it dropped again, indicating anisotropic aquifer characteristics. Three types of artificial recharge method were reviewed, including recharge wells, ditches, and ponds, and a combination of two methods is proposed: a recharge well system directly injecting into weathered soil and rock sections with good permeability, and an injection ditch that can increase the recharge effect by line-type injection in the upstream area. The extent of groundwater recharge by the selected methods will be evaluated through on-site tests and if their applicability is verified, they will contribute to securing water in areas of water shortage.

Estimation of Groundwater Contamination and Pumping Capacity for Purification in Animal Carcass Deposal Site (가축매몰지 오염지하수 정화를 위한 오염범위 및 양수량 평가)

  • Nam, Koung-Hoon;Lee, Hak-Yun;Kim, Geonha;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.25 no.1
    • /
    • pp.45-55
    • /
    • 2015
  • Purifying leachate discharged from animal carcass disposal sites requires decisions regarding the locations and numbers of boreholes. An electrical resistivity survey, known to be effective for investigating leachate distribution, was performed to evaluate the range extent of contamination due to local hydrological properties, such as groundwater flow direction, and geological structure. Results of the survey at four sites at a landfill near Icheon and Anseong, Gyeonggi Province, showed low-resistivity zones (20-200 ohm-m) at a depth of 8 m from the surface. Sites 1-4, which contain 5, 2, 4, and 2 boreholes, respectively, were estimated to have a contaminated groundwater acquisition capability of 12.9 m, 13.7 m, 10.1 m, and 18.0 m, and measured pumping capacity of 2,040 m3, 479.8 m3, 1,492.3 m3, and 691.9 m3, respectively.

Preliminary Assessment of Groundwater Artificial Recharge Effect Using a Numerical Model at a Small Basin (수치모델을 이용한 소분지에서의 지하수 인공함양 효과 예비 평가)

  • Choi, Myoung-Rak;Cha, Jang-Hwan;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.30 no.3
    • /
    • pp.269-278
    • /
    • 2020
  • In this study, the effects of groundwater artificial recharge through vertical wells in the upper small basin are preliminarily evaluated by using field injection test and a 3-D numerical model. The injection rate per well in a model is set to 20, 37.5, 60, and 75 ㎥/day based on the results of field injection test, groundwater levels, and hydraulic conductivities estimated from particle size analysis, and a numerical model using MODFLOW is conducted for 28 cases, which have diverse injection intervals, in order to estimated the changes of groundwater level and water balance after injection. Groundwater level after injection does not show a linear relationship with the injection rate per well, and the cumulative effect of artificial recharge decreases and the timing of maximum water level rise is shortened as the injection interval becomes longer. In four cases of continuous injection with total injection rate of 1,200 ㎥, it is revealed that the recharge effect is analyzed as 36.5~65.3% of the original injection rate. However, it will be more effective if the artificial recharge system combined with underground barrier is introduced for the longer pumping during a long and severe drought. Additionally, it will be possible to build a stable artificial recharge system by an establishment of efficient scenario from recharge to pumping as well as an optimization of recharge facilities.

Relationship between Groundwater Level Changes and Aquifer Characteristics during Pumping at a Radial Collector Well (방사형 집수정 취수시 대수층 특성에 따른 지하수위의 변화)

  • Choi, Myoung-Rak;Lee, Ho-Jeong;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.279-288
    • /
    • 2019
  • The groundwater drawdown at each monitoring well near a radial collector well along Anseong Stream, Korea, was measured and compared with the calculated drawdown using the mirror well concept. The drawdown calculation is performed by treating the collector well as a large vertical well in a homogeneous isotropic aquifer. The measured drawdown at each monitoring well is slightly different from the calculated value due to anisotropy in the hydraulic conductivity and aquifer thickness. The difference between the measured and calculated values at Well OW-7 is large, reaching approximately 48 cm, because a horizontal well is not installed along this direction. Sensitivity analysis of the hydraulic conductivity and aquifer thickness indicates that the hydraulic conductivity is more sensitive to groundwater level changes. Groundwater level changes become a concern when a radial collector well with a large pumping rate capacity is installed, which highlights the need to thoroughly investigate the aquifer characteristics in the surrounding area.

Estimation of optimal pumping rate, well efficiency and radius of influence using step-drawdown tests (단계양수시험을 이용한 최적 양수량, 우물효율 및 영향반경 산정)

  • Choi, Hyun-Mi;Lee, Jin-Yong;Cheon, Jeong-Yong;Jun, Seong-Chun;Kwon, Hyung-Pyo
    • The Journal of Engineering Geology
    • /
    • v.20 no.2
    • /
    • pp.127-136
    • /
    • 2010
  • Optimal pumping rate, well efficiency and radius of influence were estimated using field step-drawdown tests. According to the analysis results, optimal pumping rates were estimated as 9.37, 16.20 $m^3/day$ for KDPW 1 and 8.11, 14.10 $m^3/day$ for KDPW 2. The well efficiency was calculated as 72.02~90.73% for KDPW 1 while it was 70.62~88.52% for KDPW 2. In the meanwhile, the steady-state analysis yielded the radius of influence (ROI) of 3.50~31.92 m in case of pumping at KDPW 1 and the ROI of 0.14~37.43 m in case of pumping at KDPW 2. In addition, the transient analysis produced the ROI of 0.02~8.34 m for KDPW 1 pumping and the ROI of 0.24~9.68 m for KDPW 2 pumping. The methodology used in this study can be usefully applied in the pump and treat remediation design for contaminated groundwater.

A Model for Groundwater Time-series from the Well Field of Riverbank Filtration (강변여과 취수정 주변 지하수위를 위한 시계열 모형)

  • Lee, Sang-Il;Lee, Sang-Ki;Hamm, Se-Yeong
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.8
    • /
    • pp.673-680
    • /
    • 2009
  • Alternatives to conventional water resources are being sought due to the scarcity and the poor quality of surface water. Riverbank filtration (RBF) is one of them and considered as a promising source of water supply in some cities. Changwon City has started RBF in 2001 and field data have been accumulated. This study is to develop a time-series model for groundwater level data collected from the pumping area of RBF. The site is Daesan-myeon, Changwon City, where groundwater level data have been measured for the last five years (Jan. 2003$\sim$Dec. 2007). Minute-based groundwater levels was averaged out to monthly data to see the long-term behavior. Time-series analysis was conducted according to the Box-Jenkins method. The resulted model turned out to be a seasonal ARIMA model, and its forecasting performance was satisfactory. We believe this study will provide a prototype for other riverbank filtration sites where the predictability of groundwater level is essential for the reliable supply of water.