• Title/Summary/Keyword: Groundwater Pollution

Search Result 357, Processing Time 0.032 seconds

Hydrogeochemical Characteristics of Groundwater in Kwangiu City (광주광역시 지하수의 수리지화학적 특성 연구)

  • 이인호;조병욱;이병대;성익환;임용수
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.3
    • /
    • pp.115-132
    • /
    • 2002
  • To distinguish the anthropogenic inputs from the chemical weathering with water-rock interaction on the chemical compositons of groundwater in Kwangju city, four different water groups were established based on the landuse type, lithology and topology. The sample from greenbelt area belongs to Group Ⅰ, whereas those from green buffer zone, urban area and industrial area belong to Group II, Group Ⅲ and Group Ⅳ, respectively. The geology of this city mainly consists of biotite granite and granitic gneiss. The concentration of main cations is subject to the behavior of feldspars, micas and carbonate minerals. Cl$\^$-/ and NO$_3$$\^$-/ are supplied by anthropogenic inputs such as domestic sewage whose concentration of these anions is highest in the Group Ⅲ samples. With the Piper diagram, the groundwaters of Group Ⅲ are mainly plotted in CaSO$_4$-CaCl$_2$ type, whereas those of other groups are plotted in Ca(HCO$_3$)$_2$ type, The calculation for the activities of ions and saturation indices of some minerals shows that most of the minerals are undersaturated and plotted in the area of equlibrium with kaolinite. Three factors were extracted from the factor analysis for chemical data. Factor 1 controlled by HCO$_3$$\^$-/, Ca$\^$2-/, SO$_4$$\^$2-/, Mg$\^$2+/ and Na$\^$+/, explains the dissolution of carbonate minerals. mica and plagioclase. Factor 2, controlled by Cl$\^$-/ and NO$_3$$\^$-/, explains the influence of artificial pollution. Factor 3, controlled by Mn, Fe and Zn is subject to the industrial waste water, but the evidence is not clear. Factor 1 is dominant in the Group I and II, indicating that those samples are subjected to natural chemical weathering, The higher scores of factor 2 in the Group Ⅲ samples indicate the potential artificial pollution.

Air-sparging Technology for Remediation of Specific Aquifer Layer Using Surfactant (계면활성제를 이용한 오염대수층의 선택적 폭기기술)

  • Kim, Heon-Ki;Song, Young-Su;Kwon, Han-Joon
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.6
    • /
    • pp.23-30
    • /
    • 2008
  • Air sparging technique has been used for remediation of VOC(volatile organic compound)-contaminated aquifer. The aim of this study was to develop an innovative air sparging technique that enhances the efficiency of air intrusion into a specific horizontal layer of aquifer where the contaminants exist with the help of water-soluble surfactant. A twodimensional physical box model, packed with homogeneous sand, was used for simulating the aquifer in this study. Aqueous solution of anionic surfactant (100 mg/L, sodium dodecylbenzene sulfonate) was used to suppress the surface tension of groundwater. Three sets of experiments were conducted: air sparging experiment without surfactant application, air sparging experiments for box model where the surfactant solution was applied right above the air injection point, and air sparging experiments with surfactant solution layer formed in the middle of the box. It was found that the sparging influence zone was expanded up to five times of that formed by sparging without surfactant application. The size of sparging influence zone was more sensitive to the air flow (injection) rate with surfactant application than that without surfactant. More importantly, injection of air into the target aquifer layer was successful with surfactant application. Findings in this study are expected to provide more options for designing remediation processes using air sparging.

Development of a groundwater contamination potential evaluation technique by improving DRASTIC Index for a tunnel excavation area (개선된 DRASTIC 기법을 이용한 터널굴착 예정지역의 지하수 오염 가능성 평가기법 개발에 관한 연구)

  • Park, Jun-Kyung;Park, Young-Jin;Wye, Yong-Gon;Choi, Young-Tae;Lee, Han-Min
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.1
    • /
    • pp.71-88
    • /
    • 2003
  • The DRASTIC system is widely used for assessing regional groundwater pollution susceptibility by using hydrogeological factors such as depth to water, net recharge, aquifer media, soil media, topography, vadose zone media, hydraulic conductivity. This study is providing Modified Drastic Model to which lineament density, land use, influence of groundwater drawdown caused by tunnel excavation are added as additional factors using geographic information system, and then to evaluate groundwater contamination potential of ${\bigcirc}{\bigcirc}$ area. For statistical analysis, vector coverage per each factor is converted to grid layer and after each correlation coefficient between factors, covariance, variance, eigenvalue and eigenvector by principal component analysis of 3 direction, are calculated, correlation between factors is analyzed. Also after correlation coefficients between general DRASTIC layer and rated lineament density layer, between general DRASTIC layer and rated land use layer, between general DRASTIC layer and rated tunnel excavation influence layer are calculated, final modified DRASTIC model is constructed by using them with each weighting. When modified DRASTIC model was compared with general DRASTIC model, contamination potential in modified DRASTIC model is fairly detailed and consequently, vulnerable area which has high contamination potential could be presented concretly.

  • PDF

Characteristics of Groundwater Pollution and Contaminant Attenuation at Waste Disposal Sites (폐기물 매립지 주변의 지하수 오염과 오염물질의 지연 특성)

  • 오석영;전효택
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.1
    • /
    • pp.37-49
    • /
    • 1996
  • The objectives of this study are to investigate the groundwater and surface water contamination, to interpret the attenuation mechanism of contaminant transport, and to find the appropriate contamination indicator. at the two big landfill sites : Nanjido Landfill and Hwasung Landfill. Leachate from the Nanjido, th, Hwasung and the Kimpo waste disposal sites is characterized by high temperature (31.7-40.1$^{\circ}C$), high electric conductivity (14,650-32,800 ${\mu}$S/cm), somewhat higher pH(7.58-8.45) and low Eh (-119.4-20.4 mV), and is enriched in both major (Na$^{+}$, K$^{+}$, Ca$^{2+}$, Mg$^{2+}$, HC $O_3$$^{-}$, Cl$^{-}$) and minor (Mn, Sr$^{2+}$, Ba$^{2+}$, Li$^{+}$, F$^{-}$, Br$^{-}$) ions. Municipal solid waste leachate and industrial waste leachate are effectively discriminated by the content of S $O_4$$^{2-}$, Fe, and heavy metals. The attenuation mechanism of each component was assessed using the chemical analysis. Cl-normalizing process, WATEQ4F simulation, and preceding flownet analysis. Based on the calculation of Contamination Factor, K, Na, Ca, Mg, B, Zn, HC $O_3$, Cl, F, Br and TOC are effective contamination indicators in the Nanjido landfill site, and K, Na, Ca, Mg, B, S $O_4$, HC $O_3$, Cl, F, Br and TOC in the Habsburg landfill site Particularly, TOC is the best contamination indicator in landfill sites influenced by sea water.

  • PDF

Fundamental Study on the Wastewater Reuses for Agriculture (하수처리수의 농업용수 재이용에 관한 기초 연구)

  • Kang, Moon-Seong;Park, Seung-Woo;Kim, Sang-Min
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.393-396
    • /
    • 2002
  • The objectives of the paper are to develop the infra-technologies for reclaiming the effluents from wastewater treatment plants and reusing for agriculture water. The Suwon wastewater treatment plant has been selected for wastewater reuse tests and the water quality and treatment efficiencies are investigated. Three levels of wastewater treatments that are the effluent from the plant, sand filtering, and ultra-violet treatment are applied in the pilot system. The randomized block method was applied to wastewater application to paddy rice with five treatments, three blocks, and two replica. The control was the plots with groundwater irrigation, the other treatments are to use polluted stream flow by pumping, in addition to three wastewater treatments. The block test plots and field plots have been monitored for the water quality, soil pollution, and health hazards during the crop stages.

  • PDF

Impact of Reclaimed Wastewater Irrigation on Heavy Metal Contamination in Soil and Vegetables (하수처리수의 농업용수 재이용이 토양 및 작물의 중금속 함량에 미치는 영향 분석)

  • Kim, Hak-Kwan;Jang, Tae-Il;Lee, Eun-Jung;Park, Seung-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.827-831
    • /
    • 2008
  • In this study, the effects of reclaimed wastewater irrigation on the concentration of heavy metals such as lead, zinc, cadmium, and copper in soil and vegetables were investigated by monitoring an experimental area irrigated with reclaimed wastewater. Three treatments and three replications on $10{\times}2$-m plots were installed and heavy metal concentrations in soil and vegetables were monitored from 2005 to 2007. The treatments applied in this study were groundwater irrigation (control treatment), wastewater irrigation, and irrigation with filtered reclaimed wastewater treated with ultraviolet light. The monitored results showed that the concentrations of Cu, Cd, and Pb in soil during the experimental period were lower than initial soil levels before irrigation, whereas Zn increased in all treatment plots. However, the ranges of Zn, Cu, Cd and Pb in soil were below the soil pollution standards in the Republic of Korea. Heavy metal concentrations in vegetables showed insignificant variations for all treatments.

  • PDF

Characteristics of Groundwater Contamination in Uncontrolled Landfill and Pollution Control Measures (불량 매립지에서의 지하수 오염특성과 환경오염 방지방안)

  • 구자중;윤석표
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1993.05a
    • /
    • pp.28-44
    • /
    • 1993
  • Remediation actions in uncontrolled landfill site should be conducted after the investigation of contamination status and potential health risk or damage. Based on the above, proper control measures should be established and operated. Also continuous monitoring should be followed. In this study, the status of ground water contamination around Nanji Landfill Site was investigated. Monitoring wells were installed around the landfill and ground water was sampled once a month and analyzed. Water quality of each monitoring well was different depending on the horizontal and vertical distance from the landfill, and the seasonal leachate characteristics were not significantly changed because percolating water stayed long time in the deep waste layer. It was predicted that major multivalent cations were mainly precipitated as metal carbonate form, and chemical mass balances (CMBs) could be applied for the apportionment of leachate contamination to ground water quality of surrounding areas of Nanji Landfill. Parameters required to estimate pollutant flux to the receptor near landfill were listed and discussion to get these parameters was made. Finally, based on the above data, control measures of ground water contamination were suggested and discussed.

  • PDF

A Brief Review on Limestone Sources and Oyster Waste Generation-Bantayan

  • Yu, Kwang Sun;Thriveni, Thenepalli;Jegal, Yujin;Whan, Ahn Ji
    • Journal of Energy Engineering
    • /
    • v.26 no.1
    • /
    • pp.62-67
    • /
    • 2017
  • Limestone is an important commodity in Philippines. Limestone has numerous uses that range from agricultural applications to building materials to medicines. Many limestone products require rock with specific physical and chemical characteristics. Most limestone is biochemical in origin meaning the calcium carbonate in the stone originated from shelled oceanic creatures. In this paper, we reported the natural sources of limestone, geological formation of limestone and the oyster shell waste in Cebu, Bantayan, Philippines were reported. Due to the mining or quarrying in Cebu, Bantayan, in a limestone area poses the threat of groundwater pollution (since limestone is a porous geologic formation with a high transmissivity). The other environmental issue is oyster shell waste. The oyster shell waste is the major source of limestone. We developed and applied appropriate technologies for the extraction of limestone from oyster shell waste and utilizes as high value added material.

Remediation capabilities of pilot-scale wetlands planted with Typha aungstifolia and Acorus calamus to treat landfill leachate

  • Bhagwat, Rohit V.;Boralkar, Dilip B.;Chavhan, Ram D.
    • Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.191-198
    • /
    • 2018
  • Improper management and unsanitary approaches are implemented in disposal of leachate, which has resulted in groundwater pollution at village Uruli Devachi, Pune, India. Various physico-chemical treatment methods are commercially available for leachate treatment. However, the application of biological methods viz. phytoremediation to the municipal solid waste landfill leachate has been limited. We report the remediation ability of Typha aungstifolia and Acrorus calamus that is capable of reducing hazardous constituents from the landfill leachate. After 96 h of hydraulic retention time (HRT), it was observed that T. aungstifolia-treated sample showed high reduction potential in reducing biochemical oxygen demand, chemical oxygen demand, hardness, total dissolved solids, Na, Mg, Ca and Ni whereas A. calamus showed greater reduction capacity for alkalinity, Cl, Cu, Zn and Cr. Furthermore, it was also observed that T. aungstifolia withstood longer HRT than A. calamus. In situ application of T. aungstifolia and A. calamus for remediation of landfill leachate carries a tremendous potential that needs to be further explored.

Underground cavity remediation using membrane grouting method

  • Seung-Hyun Kim;Young-Hoon Jung;Jong-Ho Shin
    • Geomechanics and Engineering
    • /
    • v.38 no.5
    • /
    • pp.455-466
    • /
    • 2024
  • Ground collapse may occur around the tunnel when the cavity caused by groundwater runoff cannot resist the surcharge load. Any cavities or subsidence must be managed to avoid dangerous situations by stabilizing the ground through appropriate remedial measures. Trench and trenchless grouting methods can generally be used for the cavity restoration. The trench method is difficult to properly control the injection range and may cause environmental problems due to grout leakage and damages to the adjacent structures due to grouting pressure. In this study, Membrane-grouting method (MGM) is proposed, which, can be an appropriate trenchless grouting method that fills the void tightly and effectively controls the injection range. This method can be an alternative to eliminating the influence of adjacent structures and environmental pollution by inserting a membrane into the cavity and filling the membrane with grout. The membrane blocks the outflow of grout. In addition, it is easy to control the injection pressure to avoid heaving failure. This paper investigates the principle and application of the MGM using a theoretical method, model test and numerical analysis.