• 제목/요약/키워드: Groundwater

검색결과 5,746건 처리시간 0.043초

지하수 채수에 따른 지반침하 사례분석

  • 정하익;구호본
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.168-171
    • /
    • 2001
  • It is a common practice to extract water from the ground for domestic, agricultural or industrial uses or to lower the groundwater level for construction work. An accurate prediction of ground settlement Is sometimes crucial when groundwater is pumped. This case study have shown that drawdown of the groundwater table may cause ground subsidence. Many settlement gauges was installed in the vicinity of a pumped well to measure the surface settlement. The relationships between the level of groundwater drop and surface settlement is investigated In this research.

  • PDF

유구지역에서의 누적강수량과 지하수수위강하를 이용한 지하수함양율 추정

  • 이주영;이기철;정형재;정성욱
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.515-518
    • /
    • 2003
  • Groundwater recharge rate can be estimated from groundwater head rebound due to rainfall. Groundwater level changes are monitored for 10 months at Yugu area. Difference between two recharge rates calculated by rainfall and by effective rainfall is 1.1%~1.6%. Since this method ignores soil water percolation during groundwater level regression, the actual recharge rate may be higher than estimated one by cumulative rainfall and groundwater level change.

  • PDF

Groundwater Fluxes in a Watershed with a Lake

  • Bae, Sang-Keun
    • Korean Journal of Hydrosciences
    • /
    • 제7권
    • /
    • pp.9-19
    • /
    • 1996
  • The purpose of this study is to investigate the influence of the position of lake upon groundwater fluxes on a lake watershed, and to provide for the monitoring network design to survey the exchange relations between groundwater and lake water. Three kinds of hypothetical flow through lakes, which are located at the upper, middle, and lower portion of a watershed were considered. Groundwater flow for each case was numercally simulated under three-dimensional steady state conditions. The exchange rates of the groundwater, the amounts of recharge and discharge, and groundwater fluxes between lake and groundwater in a watershed system with a lake were clarified.

  • PDF

Assessment of groundwater contamination susceptibility based on water chemistry data - A review

  • Kim, Kang-Joo;Natarajan Rajmohan;Chae, Gi-Tak;Yun, Seong-Taek
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.12-15
    • /
    • 2004
  • Groundwater contamination susceptibility studies have many advantages in groundwater monitoring, management and future planning. Several methods have been developed and applied to the groundwater regime through out the world. However, each and every method has some limitations. In this study, a detailed review was carried out about the already existing methods for groundwater contamination susceptibility studies. Additionally, a new parameter called mineral dissolution factor is recommended for groundwater contamination susceptibility studies. This parameter is applied for groundwate contamination susceptibility studies in Namwon area, Korea. The result of this approach suggests that mineral dissolution parameter could overcome the limitations as observed in the earlier methods.

  • PDF

창원지역 지하수 수질과 DRASTIC에 의한 지하수 오염취약성 평가

  • 김무진;함세영;정재열;장성;차용훈
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.459-462
    • /
    • 2004
  • This study assesses groundwater vulnerability to contaminants in 12 administrative districts of the city of Changwon, using DRASTIC technique. DRASTIC was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. However, groundwater contamination in urban areas can also be related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is low as 0.40. The correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other factors such as groundwater withdrawal rate and well density per unit area with ratings and weights as well as the existing six DRASTIC factors.

  • PDF

창원지역 지하수의 수질특성

  • 김무진;함세영;황한석;성익환
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.191-193
    • /
    • 2001
  • This paper presents the result of groundwater analysis in Changwon area and the characteristics of the groundwater properties. Changwon city conducted groundwater analysis at 551 sites in 1996 and 1997. The water quality is suitable as groundwater use at 466 sites (84.6 %) and exceeds maximum contaminant levels (MCLs) at 85 sites (15.4 %). Major contaminants are total bacteria, coliform and nitrate-N. DNAPLs, e.g. TCE and PCE are detected in the areas of industrial complex and residence. The detection of TCE and PCE is due to organic solvents from manufacturing companies. They are also derived from laundries, Photographer's studios, septic tanks, etc. In addition, fifty groundwater samples were analyzed. Iron, manganese, zinc, copper, lead, aluminum and fluorine are detected in nearly all the groundwater samples. The groundwaters shown on the Piper diagram mostly belong to Ca-HCO$_3$ type.

  • PDF

지반.지하수 조건을 고려한 최적의 지하수 이용 공조 시스템 선정에 관한 연구 (Study on Optimization of Design and Operation for Groundwater Heat Pump System Considering Ground and Groundwater Condition)

  • 남유진;오오카 료죠;황석호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.731-736
    • /
    • 2006
  • Groundwater heat pump (GWHP) system has been expected to achieve the higher coefficient of performance (COP) and more energy-saving than the conventional air-source heat pump (ASHP) system. Its performance significantly depends on the characteristics of groundwater and the underground thermal properties. Furthermore, there is a large difference of COP in utilizing groundwater between as a heat resource and as a thermal storage medium. For properties of groundwater there is suitable utilizing system. However, many of GWHP systems have not been considered sufficiently such properties. This research describes optimization of GWHP system according to the properties of groundwater based on 3D numerical heat and water transport simulation.

  • PDF

MOM-Bentonite 투수성반응벽체를 이용한 PCE로 오염된 지하수의 정화 (Remediation of PCE-contaminated Groundwater Using Permeable Reactive Barrier System with M0M-Bentonite)

  • 정성래;이달희
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권4호
    • /
    • pp.73-80
    • /
    • 2012
  • The objectives of this research were to study the applicability and limitations of permeable reactive barrier (PRB) for the removal of tetrachloroethylene (PCE) from the groundwater. PRB column tests were conducted using reactive material with Moringa Oleifera Mass - Bentonite (Mom-Bentonite). Most of the PCE in the groundwater was degraded and/or captured (sorpted) in the zone containing activated material (MOM-Bentonite). The removal rate of PCE from the groundwater was 90% and 75% after 30 days and 180 days, respectively. The effect of micro-organisms on the long-term permeability and reactivity of the barrier is not well understood. MOM-Bentonite PRB system in this research has the potential to be developed into an environmentally and economically acceptable technology for the in situ remediation of PCE-contaminated groundwater.

Distribution of Rare Earth Elements and Their Applications as Tracers for Groundwater Geochemistry - A Review

  • Hwang, Heejin;Nyamgerel, Yalalt;Lee, Jeonghoon
    • 한국지구과학회지
    • /
    • 제42권4호
    • /
    • pp.383-389
    • /
    • 2021
  • Several studies investigating the behavior and environmental distribution of rare earth elements (REEs) have been reviewed to determine the geochemical processes that may affect their concentrations and fractionation patterns in groundwater and whether these elements can be used as tracers for groundwater-rock interactions and groundwater flow paths in small catchments. Inductively coupled plasma-mass spectrometry (ICP-MS), equipped with an ultrasonic nebulizer and active-film multiplier detector, is routinely used as an analytical technique to measure REEs in groundwater, facilitating the analysis of dissolved REE geochemistry. This review focuses on the distribution of REEs in groundwater and their application as tracers for groundwater geochemistry. Our review of existing literature suggests that REEs in ice cores can be used as effective tracers for atmospheric particles, aiding the identification of source regions.