• 제목/요약/키워드: Ground vibration source

검색결과 74건 처리시간 0.022초

철도연변 지반 진동 Data Base 구축을 통한 지반진동예측 실험식 (Development of Empirical Equations for Estimating the Train-Induced Ground Vibration)

  • 황선근;고태훈;엄기영;오상덕
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1022-1027
    • /
    • 2001
  • In this study, the train-induced vibration was measured at many locations at/around the actual service lines and the data base was constructed using the measurement results. The characteristics of train induced ground vibration was categorized and the empirical ground vibration estimating equations were developed. On the ground area (level grounds, embankments, cut sections), the vibration estimating equations were developed in terms of ground vibration level which was related with the distance from the source. Especially for the cut section areas, the vibration levels were expressed with the vibration receiving point expressed by the ratio of vertical distance to horizontal distance(V/H) from the source. As a result, when V/H is 0.96, the vibration estimating equation gives a minimum vibration level.

  • PDF

방진체결구/방진매트의 진동저감특성에 관한 연구 (A Study on the Vibration Reduction Characteristics of the Elastic Rail Fastener/Ballast Mat)

  • 엄기영;황선근;고태훈;김정근
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 춘계학술대회 논문집
    • /
    • pp.375-380
    • /
    • 2001
  • Generally, countermeasures for the train-induced vibration are divided into the measures at the source, propagation path and receiving object. Among these measures the countermeasure at the source location is the most active and effective one in the field of railroad. In this study, the effectiveness of each anti-vibration measures at the track(source location) such as elastic rail fastener, ballast mat were evaluated through the comparison of acceleration level, insertion loss at the installed locations of each measures. As result of field measurement of vibration at the railroad track supporting structures and on the ground nearby the structures, elastic rail fastener showed vibration reduction effect of 4.5 ∼7.3㏈ on the concrete slab, 1.6∼3.7㏈ on the ground with the train operation speed of 80km/hr. In the case of ballast mat, the vibration reduction effect at the concrete slab and on the ground were 11.9∼13.3㏈ and 6.1∼7.6㏈, respectively.

  • PDF

도심지 발파공사장의 발파진동 특성 (The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area)

  • 이연수;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.521-526
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, Z(perpendicularity) axis was the highest value in vibration level, but vertical axis was the highest value at 25m point and longitudinal axis was the highest value at 50m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, 2 axis was the highest value in vibration level, but in vibration velocity transverse axis was the highest value at ground, was vertical axis at 1st floor, was longitudinal axis at 3rd floor and was vertical and longitudinal axis at 5th floor. The vibration level and the vibration velocity of 50m point showed higher correlation value than 25m point at the ground, but those of 25m point showed higher correlation value than 50m point at the apartment.

  • PDF

도심지 발파공사장의 발파진동 특성 (The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area)

  • 장서일;이연수
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.632-638
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured by the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, 2 (perpendicularity) axis was the highest value in vibration level, but vertical direction was the highest value at 25 m point and longitudinal direction was the highest value at 50 m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, Z axis was the highest value in vibration level, but in vibration velocity transverse direction was the highest value at ground, was vertical direction at 1st floor, was longitudinal direction at 3rd floor and was vertical and longitudinal direction at 5th floor. The vibration level and the vibration velocity of 50 m point showed higher correlation value than 25 m point at the ground, but those of 25 m point showed higher correlation value than 50 m point at the apartment.

지하철 운행에 의한 인접건물의 진동영향 평가 연구 (Reduction and Evaluation of Subway Induced Vibration Effects on Surrounding Buildings)

  • 박지훈;민경원;이루지;최석주;염성곤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.738-742
    • /
    • 2005
  • Ground vibration at Gil-dong in Seoul induced by the 5th ling of Seoul Subway is predicted using various prediction methods and compared with measured vibration. Also, several issues on the improvement of prediction methods are discussed. Furthermore, as an alternative vibration source, measured vibration acceleration level(VAL) on the tunnel wall of the Bundang line of Seoul Subway is applied to the prediction of the VAL at the location mentioned previously. Then requirements accompanied to the suggestion of the new vibration source appropriate to the condition of Seoul Subway.

  • PDF

실측파형과 유한요소해석을 통한 방진구의 위치별 진동 저감 연구 (A Study on the Vibration Reduction by the Position of Borehole using Experimental Waveform and Finite Element Analysis)

  • 송정언;김승곤;박훈;홍웅기
    • 환경영향평가
    • /
    • 제22권4호
    • /
    • pp.381-387
    • /
    • 2013
  • In order to improve the environmental vibration, it is necessary to method for not only reduce the vibration source, but also control the vibration path. In this study, we used borebole for estimate the vibration reduction. And also, we analyzed displacement and vibration velocity caused by the position of borehole as well as the condition of borehole in ground structure. Visual FEA(Finite Element Analysis) program was used in this numerical analysis. The results are as follows : The displacement magnitude and X, Y direction displacement were represented to different results due to the condition and position of borehole, and were represented to the lowest values when the position of borehole is the most close condition from the vibration source. And also, the vibration velocity was decreased as using borebole in ground structure. The isolation efficiency of the vibration was calculated to maximum 18.40% when borehole was established to the most close position from the vibration source and the receive point.

지표면의 반사특성을 고려한 환경소음 예측 (Prediction of Industrial Noise Propagation Subjected to Ground Effect)

  • 한상보
    • 소음진동
    • /
    • 제11권2호
    • /
    • pp.329-335
    • /
    • 2001
  • The analytical model of the ground wave can be used for the prediction of the noise level from a source above a plain and homogeneous ground surface with no obstacles nearby. Sound propagation along the surface of the ground can be affected by the roughness of the ground surface and the direction of the wind. The effects of the ground surface and the wind can be formulated in terms of the ground coefficient and the noise source parameter. Upward and downward conditions can also be addressed by considering the direction of the wind. The ground coefficient and the noise source parameter are estimated using the measured noise levels of two points under particular environmental condition, and the noise levels of arbitrary points under the same environmental condition can be estimated. The proposed method can be utilized to estimate the noise level of specific noise environment and its validity was confirmed with the results of actual field measurement.

  • PDF

열차하중에 의한 인접 지반의 진동 감쇠 특성 분석 (Analysis of Vibration Damping Characteristics of the Ground Nearby Railroad Induced by Train Loading)

  • 이주호;박광순;박경래;염종윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.223-228
    • /
    • 1997
  • In this study, the vibration were measured to analyze the characteristics of propagating vibration on the railroad, the roadbed and the ground nearby railroad induced by traveling trains. About Fifty cases of passing trains were measured with different types and speed, changing the source of loading and the points of measurement. The measured signals were analyzed in time domain and frequency domain. As a result of analysis, sudden reduction of energy was shown in near part from vibration source and the contents of high frequency was reduced more rapidly as the distance was increased. The amplitude of vibration and the contents of frequency did not make big differences in spite of different types of train which is recently used in Korea.

  • PDF

An innovative vibration barrier by intermittent geofoam - A numerical study

  • Majumder, Mainak;Ghosh, Priyanka;Sathiyamoorthy, Rajesh
    • Geomechanics and Engineering
    • /
    • 제13권2호
    • /
    • pp.269-284
    • /
    • 2017
  • A new technique is proposed to obtain more effective screening efficiency against the ground vibration using intermittent geofoam (IF) in-filled trench. The numerical analysis is performed by employing two-dimensional finite element method under dynamic condition. Vertically oscillated strip foundation is considered as the vibration source. In presence of the ground vibration, the vertical displacements at different locations (pick-up points) along the ground surface are captured to determine the amplitude reduction factor (ARF), which helps to assess the efficiency of the vibration screening technique. The efficiency of IF over continuous geofoam (CF) in-filled vibration barriers is assessed by varying the geofoam density, the location of trench and the frequency of excitation. The results from this study indicate that a significant reduction in ARF can be achieved by using intermittent geofoam as compared to continuous geofoam. Further, it is noticed that the efficiency of IF increases with an increase in the frequency of the vibrating source. These encouraging results put forward the potential of utilising intermittent geofoam as a vibration screening material.

PSD선도를 이용한 국내노면의 상관성 분석에 관한 연구 (The Study on Interrelationship Analysis of Domestic Road Using PSD)

  • 김찬중;권성진;이봉현;김현철;배철용
    • 한국소음진동공학회논문집
    • /
    • 제16권8호
    • /
    • pp.806-813
    • /
    • 2006
  • An important factor of vibration test using MAST(multi axial simulation table) system is the reliance of input excitation source. Generally the generation of input excitation source is obtained by the measured data on special road in proving ground. The measured data on special road have more exciting energy than the data of real fields, therefore the time and expense for test can be reduced. But the magnitude of input excitation source must be defined by comparison with the excited energy on real field. The object of this paper makes the data base of domestic roads for the definition of input excitation source which is obtained by the measured data on special road in proving ground. These real field data on domestic roads are analyzed by the power spectral density and interrelationship index.