• 제목/요약/키워드: Ground temperature

검색결과 1,603건 처리시간 0.03초

LNG 지하 저장탱크 벽체의 비선형 열응력 해석 (Nonlinear Thermal Stress Analysis of In-ground LNG Storage Tank)

  • 곽효경;송종영;이광모
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 봄 학술발표회논문집
    • /
    • pp.111-118
    • /
    • 2000
  • Concrete cracking due to the temperature gradient across the wall, caused by the difference in temperature between cryogenic liquid natural gas stored and surrounding environment of in-ground LNG storage tank, is investigated in this study. Crack propagation of concrete LNG tank is effectively simulated by using a layered degenerated shell element. In addition, material nonlinearity is taken into consideration on the basis of the nonlinear elastic-orthotropic model. Finally, numerical analysis for a real LNG storage tank is conducted with the objective to verify the efficiency of the introduced model.

  • PDF

직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가 (Evaluation of the Annual Performance of the Direct Expansion Vertical Closed-Loop Ground Source Heat Pump)

  • 김민성;우정선;백영진;장재철;김지영;라호상
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.534-542
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed-loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As a result, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

  • PDF

주거용 직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가 (Annual Performance Evaluation of Direct Expansion Vertical Closed-Loop Ground Source Heat Pump for Residential Application)

  • 김민성;백영진;라호상
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.114-122
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed -loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As results, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

학교 건물에 설치된 지열원 열펌프 시스템의 실사용을 통한 냉난방성능 연구 (Cooling and Heating Performance Under the Actual Operating Condition of a Ground Source Heat Pump System in a School Building)

  • 김의영;정영만;송재도;이재근;김인규;이동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.586-589
    • /
    • 2009
  • This paper presents the performance of a water-to-refrigerant type ground source heat pump (GSHP) system installed in a school building in Korea. For analyzing the performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the input power of the GSHP system. The average cooling coefficient of performance (COP) of the heat pump was found to be 8.5 at 60% partial load condition, while the overall system COP was found to be 5.9. The average heating COP of the heat pump was found to be 6.5 at 45% partial load condition, while the overall system COP was found to be 5.0.

  • PDF

Study on an Electrode Attachment Method Suitable for Underwater Electromyography Measurements

  • Han, Seul-ki;Park, Jung-seo;Nam, Taek-gil
    • 대한물리의학회지
    • /
    • 제10권2호
    • /
    • pp.95-98
    • /
    • 2015
  • PURPOSE: This study was conducted to devise a method of preventing water infiltration into the surface electrodes during EMG measurements underwater and on the ground and to check the reliability of Electromyography (EMG) measurements when underwater. METHODS: Six healthy adults were selected as subjects in this study. The measurements in this study were conducted in pool dedicated to underwater exercise and physical therapy room in the hospital building. An MP150 (Biopac Systems, US, 2010) and a BioNomadix 2-channel wireless EMG transmitter (Biopac Systems, US, 2012) was used to examine the muscle activity of rectus femoris, biceps femoris, tibialis anterior, gastrocnemius of dominant side. The subjects repeated circulation tasks on the ground for more than 10 min for enough surface electrode attachment movement. After a 15-min break, subjects performed the circulation task underwater(water depth 1.1m, water temperature $33.5^{\circ}C$, air temperature $27^{\circ}C$), as on the ground, for more than 10 min, and the MVIC of each muscle was measured again. SPSS v20.0 was used for all statistical computations. RESULTS: The maximum voluntary isometric contraction (MVIC) values between the underwater and on the ground measurements showed no significant differences in all four muscles and showed a high intraclass correlation coefficient (ICC) of >0.80. CONCLUSION: We determined that EMG measurements obtained underwater could be used with high reliability, comparable to ground measurements.

UM 자료를 이용한 노면온도예측모델(UM-Road)의 개발 (Development of Road Surface Temperature Prediction Model using the Unified Model output (UM-Road))

  • 박문수;주승진;손영태
    • 대기
    • /
    • 제24권4호
    • /
    • pp.471-479
    • /
    • 2014
  • A road surface temperature prediction model (UM-Road) using input data of the Unified Model (UM) output and road physical properties is developed and verified with the use of the observed data at road weather information system. The UM outputs of air temperature, relative humidity, wind speed, downward shortwave radiation, net longwave radiation, precipitation and the road properties such as slope angles, albedo, thermal conductivity, heat capacity at maximum 7 depth are used. The net radiation is computed by a surface radiation energy balance, the ground heat flux at surface is estimated by a surface energy balance based on the Monin-Obukhov similarity, the ground heat transfer process is applied to predict the road surface temperature. If the observed road surface temperature exists, the simulated road surface temperature is corrected by mean bias during the last 24 hours. The developed UM-Road is verified using the observed data at road side for the period from 21 to 31 March 2013. It is found that the UM-Road simulates the diurnal trend and peak values of road surface temperature very well and the 50% (90%) of temperature difference lies within ${\pm}1.5^{\circ}C$ (${\pm}2.5^{\circ}C$) except for precipitation case.

실험과 수치해석을 통한 동토지반 안정화용 수직형 열사이펀의 성능평가 (Experimental and Numerical Investigation of the Performance of Vertical Thermosyphon for Frozen Ground Stabilization)

  • 이장근;이철호;장창규;최창호
    • 한국지반신소재학회논문집
    • /
    • 제13권4호
    • /
    • pp.45-56
    • /
    • 2014
  • 한대지역은 계절 변화에 따라 동결융해가 반복되는 상부의 활동층과 하부의 영하상태로 항시 유지되는 영구동토층으로 구성되어 있다. 한대지역에서 여름철에는 동결되어 있는 지반을 융해시키기 때문에 지반 강도저하 및 침하가 발생한다. 이러한 강도저하 및 침하는 상부 구조물의 구조적 안정성에 문제를 야기시켜 활동층을 포함하고 있는 한대지역에서는 지반의 온도를 항시 영하상태로 유지할 수 있는 동결지반 안정화 공법이 필요하다. 열사이펀이란 구조체 내부에 충전된 냉매의 자가적인 열순환에 의해 지반의 온도를 항시 영하상태로 유지할 수 있는 지반 안정화 공법 이다. 본 연구에서는 열사이펀의 지반 동결성능을 분석하기 위해 R-134a 냉매를 이용하여 충전율에 따른 열사이펀의 지반 온도제어를 실내실험과 수치해석을 통해 분석하고 열사이펀의 열전도율을 산정하였다.

LNG 탱크에서 천연가스 유출시 얕은 기초 주변 지반거동의 수치해석적 분석 (Numerical Analysis of Behavior of Ground Near LNG Tank Foundation Under Scenario of LNG Leakage)

  • 김정수;김영석;이기철;김동욱
    • 한국지반신소재학회논문집
    • /
    • 제17권4호
    • /
    • pp.81-92
    • /
    • 2018
  • 최근 천연가스에 대한 수요가 높아지면서 이를 저장하기 위한 LNG 탱크의 건설이 증가하고 있다. LNG는 효율적인 저장을 위해 극저온의 유체로 액화되므로, LNG 탱크의 결함으로 인한 LNG 유출은 막대한 피해를 야기할 수 있다. 많은 연구자들이 다양한 LNG 유출 상황에 대하여 발생가능 한 피해 영향을 평가하였으나, 극저온의 LNG 유체가 유출될 경우 LNG 탱크를 지지하고 있는 지반에 미치는 영향에 대한 연구는 제한적이다. 따라서 본 논문에서는 LNG 탱크 및 지반의 다양한 조건을 고려하여 LNG 유출에 따른 동결 지반의 역학적, 열적 거동 변화에 대한 연구를 수행하였다. 유출 시나리오의 구현을 위해 수치해석을 수행하였으며, 상재하중, 온도 경계조건, 흙의 동결 민감성 변화에 따른 지반과 기초구조물 거동을 조사하고자 하였다. 이를 통해 LNG 유출 이후 지반의 단기 및 장기 온도변화를 평가하였으며, 지반 동결에 따른 간극 및 연직변위 변화를 분석하였다.

Quantitative Microbial Risk Assessment for Campylobacter jejuni in Ground Meat Products in Korea

  • Lee, Jeeyeon;Lee, Heeyoung;Lee, Soomin;Kim, Sejeong;Ha, Jimyeong;Choi, Yukyung;Oh, Hyemin;Kim, Yujin;Lee, Yewon;Yoon, Ki-Sun;Seo, Kunho;Yoon, Yohan
    • 한국축산식품학회지
    • /
    • 제39권4호
    • /
    • pp.565-575
    • /
    • 2019
  • This study evaluated Campylobacter jejuni risk in ground meat products. The C. jejuni prevalence in ground meat products was investigated. To develop the predictive model, survival data of C. jejuni were collected at $4^{\circ}C-30^{\circ}C$ during storage, and the data were fitted using the Weibull model. In addition, the storage temperature and time of ground meat products were investigated during distribution. The consumption amount and frequency of ground meat products were investigated by interviewing 1,500 adults. The prevalence, temperature, time, and consumption data were analyzed by @RISK to generate probabilistic distributions. In 224 samples of ground meat products, there were no C. jejuni-contaminated samples. A scenario with a series of probabilistic distributions, a predictive model and a dose-response model was prepared to calculate the probability of illness, and it showed that the probability of foodborne illness caused by C. jejuni per person per day from ground meat products was $5.68{\times}10^{-10}$, which can be considered low risk.

저심도 저비용 유닛형 지중열교환기의 개발 (Development of low-cost, low-depth unit-type ground heat exchanger)

  • 오진환;남유진;채호병
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.166-167
    • /
    • 2014
  • Recently, in according to increase cognizance of energy and resources exhaustion, renewable energy system is received attention. In particular, ground heat pump system(GSHP) utilizing annually stable ground temperature for energy saving have been attracted in many buildings. However, GSHP system have disadvantage due to increase of initial installation and boring cost. In this study, in order to reduce the initial cost and to supply ground heat pump system into small scale house, an unit-type ground heat exchanger was developed.

  • PDF