• Title/Summary/Keyword: Ground reaction

Search Result 768, Processing Time 0.03 seconds

Analysis of Variability for the Components of VGRF Signal via Increasing the Number of Attempt during Running (달리기 시도 수 증가에 따른 VGRF 신호 성분의 Variability 분석)

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.129-134
    • /
    • 2007
  • The purpose of this study was to determine the variability of components of the vertical ground reaction force signal to seek the suitable number of attempt datum to be analyzed during running at 2m/s and 4m/s. For this study, six subjects (height mean:$174.5{\pm}4.4cm$, weight $671.5{\pm}116.4N.$, age:$25.0{\pm}yrs.$) were selected and asked to run at least 3 times each run condition randomly. FFT(fast Fourier transform) was used to analyze the frequency domain analysis of the vertical ground reaction forces signal and an accumulated PSD (power spectrum density) was calculated to reconstruct the certain signal. To examine the deviation of the vertical ground reaction between signals collected from an different number of attempt, variability of frequency, magnitude of passive peak, time up to the passive peak and maximum load rate were determined in a coefficient of variance. The variability analysis revealed that when analyze the vertical reaction force components at 2m/s speed running, which belongs to slow pace relatively, it would be good to calculate these components from signal of one attempt, but 4m/s speed running needs data collected from two attempts to decrease the deviation of signal between attempts. In summary, when analyzing the frequency and passive peak of the vertical reaction force signal during the fast run, it should be considered the number of attempt.

HBr Formation from the Reaction between Gas-phase Bromine Atom and Vibrationally Excited Chemisorbed Hydrogen Atoms on a Si(001)-(2 X1) Surface

  • Ree, J.;Yoon, S.H.;Park, K.G.;Kim, Y.H.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.8
    • /
    • pp.1217-1224
    • /
    • 2004
  • We have calculated the probability of HBr formation and energy disposal of the reaction exothermicity in HBr produced from the reaction of gas-phase bromine with highly covered chemisorbed hydrogen atoms on a Si (001)-(2 ${\times}$1) surface. The reaction probability is about 0.20 at gas temperature 1500 K and surface temperature 300 K. Raising the initial vibrational state of the adsorbate(H)-surface(Si) bond from the ground to v = 1, 2 and 3 states causes the vibrational, translational and rotational energies of the product HBr to increase equally. However, the vibrational and translational motions of product HBr share most of the reaction energy. Vibrational population of the HBr molecules produced from the ground state adsorbate-surface bond ($v_{HSi}$ =0) follows the Boltzmann distribution, but it deviates seriously from the Boltzmann distribution when the initial vibrational energy of the adsorbate-surface bond increases. When the vibration of the adsorbate-surface bond is in the ground state, the amount of energy dissipated into the surface is negative, while it becomes positive as vHSi increases. The energy distributions among the various modes weakly depends on surface temperature in the range of 0-600 K, regardless of the initial vibrational state of H(ad)-Si(s) bond.

Decoupling Method Between Digital Signals on FPCB and Mobile Handset Antenna

  • Kim, Joon-Chul;Kim, Hyeong-Dong
    • ETRI Journal
    • /
    • v.33 no.1
    • /
    • pp.121-124
    • /
    • 2011
  • Digital harmonics, which may reduce the radio frequency sensitivity of a system, can be coupled with an antenna in a mobile handset. This letter presents a decoupling method for increasing the isolation between digital harmonics on a flexible printed circuit board (FPCB) and an antenna in terms of the ground mode current and the concept of reaction. We model the signal and ground lines in an FPCB as a loop circuit exciting a ground mode current and demonstrate a simple but efficient decoupling method for reducing the excited ground mode current.

Analysis of ground reaction force contributing to horizontal velocity factors in short distance 100M race (육상 단거리 100m 수평속도 요인에 기여하는 지면반력분석)

  • Choi, Su-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2134-2141
    • /
    • 2014
  • This study was to analyze ground reaction force according to Crouching Start type at the starting point of 100M race. The subjects of this study were 8 women sprinters and we analyzed their ground reaction force by classifying the distance between start blocks as three types. The followings are the results of the study. According to maximum horizontal ground reaction force analysis result, in the left foot placed in front, BS among excellent group and MS in non-excellent group showed the biggest reaction force value. In the right foot placed at the back, MS in both groups showed the biggest reaction force value. MS in the right foot of the excellent group was the biggest (0.83 BW). According to maximum vertical ground reaction force analysis result, in the left foot placed in front, ES among excellent group and BS in non-excellent group showed the biggest reaction force value. In the right foot placed at the back, BS among excellent group and MS in non-excellent group showed the biggest reaction force value.

Gait Analysis System Using Infrared LED Landmarks (적외선 LED 랜드마크를 이용한 보행분석 시스템)

  • Nhut, Do-Tri;Suh, Young-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.7
    • /
    • pp.641-646
    • /
    • 2011
  • A low cost gait analysis system, which can measure stride length, walking speed, and ground reaction force, is proposed. A gait analysis system is used for medical evaluation of patients and rehabilitation assistance. Low cost cameras are attached to a shoe and movement of a shoe is estimated using infrared LED landmarks. Ground reaction force is measured from pressure sensors, which are installed inside a shoe. Through experiments, it is shown that the proposed system can be used to obtain stride length, walking speed, and ground reaction force.

The Benefits of Stick Walking: Evaluation at Ankle, Knee and Hip Joints

  • Kim, Suk-Won;Lee, Jung-Yong;Park, Ki-Won;Yoon, Hoon-Yong;Park, Sung-Ha
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.63-71
    • /
    • 2005
  • A laboratory study was performed to evaluate the effects of an aid(i.e. stick) on joint loadings. Six healthy young participants were recruited from Virginia Tech student population. Each participant has performed three normal walking and three stick walking trials. Normalized and integrated, ground reaction forces(GRFs) and joint moments were measured at ankle, knee, and hip joints from kinematic and kinetic data. The result suggests that stick walking significantly reduces vertical ground reaction force and joint moments at ankle and knee compared to normal walking.

A study of the effect of walking speed upon gait parameters and foot-ground reaction forces (보행속도가 보행특성모수 및 지면반발력에 미치는 영향에 관한 연구)

  • 황규성;정민근;이동춘
    • Journal of the Ergonomics Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.93-101
    • /
    • 1992
  • Gait parameters for the Korean normal adults were compared with sex and age. Time-distance measurements and ground reaction force parameters were studied in relation to walking speed. Regression analysis was performed to establish functional relations between walking speed and various gait parameters. It is found that cardence and stride length varied linearly with walking velocity whereas time of double support was inversely proportional to walking velocity. The amplitude of ground reaction force was increased with increasing velocities of gait due to the greater heel-strike force and toe-off forces associated with these higher velocities. The results of this study can be usefull utilized as basic data to design and evaluate prosthetic devices, and to detect abnormal gait performances.

  • PDF

Biomechanical evaluations of four different AK prostheses by using GRF(Ground Reaction Force) and energy consumption at Stance Phase (입각기에서의 지면반발력과 에너지 소모를 이용한 대퇴의지별 생체역학적 평가)

  • Kim, S.M.;Park, C.I.;Choi, S.O.;Shin, J.C.;Kim, D.Y.;Kim, N.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.82-83
    • /
    • 1998
  • In this study, variation of ground reaction force and energy consumption are investigated while walking with four different AK prostheses in order to obtain basic biomechanical data for developing AK prosthesis for Korean. It is a important information to investigate ground reaction force(GRF) and energy consumption to evaluate efficiency and stability of the prostheses.

  • PDF

Faster Detection of Step Initiation for the Lower Limb Exoskeleton with Vertical GRF Events

  • Cha, Dowan;Kang, Daewon;Kim, Kab Il;Kim, Kyung-Soo;Lee, Bum-Joo;Kim, Soohyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.733-738
    • /
    • 2014
  • We propose a new approach called as a peak time approach for faster detection of step initiation for the lower limb exoskeleton. As faster detection of step initiation is an important criterion in evaluating the lower limb exoskeleton, many studies have investigated approaches to detect step initiation faster, including using electromyography, the center of pressure, the heel-off time and the toe-off time. In this study, we will utilize vertical ground reaction force events to detect step initiation, and compare our approach with prior approaches. Additionally, we will predict the first step's heel strike time with vertical ground reaction force events from multiple regression equations to support our approach. The lower limb exoskeleton should assist the operator's movement much faster and more reliably with our approach.

A Study on The Assessment Method of Gait Analysis for Ankle Assembly Using Ground Reaction Force (지면반발력을 이용한 인공족관절의 보행평가 기법에 관한 연구)

  • Kim Sung Min;Kim Sung Jae;Bae Ha Suk;Choi Byoung Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.197-204
    • /
    • 2005
  • In this study, ground reaction force(GRF), absolute symmetry index(ASI) and coefficient of variation(CV) of fixed, single-axis and multi-axis prosthetic ankle assemblies were investigated to show the biomechanical evaluation for above knee amputees. In the experiments, 37 normal male volunteers, two male and two female AK amputees were tested with fixed, single-axis and multi-axis prosthetic ankle assembly. A gait analysis was carried out to derive the ratio of GRF to weight as the percentage of total stance phase for ten points. The results showed that fixed-axis ankle was superior to the other two ankle assemblies for the characteristic of forwarding and breaking forces. Multi-axis ankle was relatively superior to the other two ankle assemblies for gait balancing and movement of the center for mass. single-axis ankle was relatively superior to the other two ankle assemblies for CV and ASI of GRF.