접지시스템에서 접촉전압과 보폭전압의 비교측정 (Comparative Measurement of Touch and Step Voltages in Ground Systems)

  • 김황국;문병두;박대원;길경석;한주섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.311-315
    • /
    • 2008
  • Ground systems set the reference voltage level of circuit and system, and suppress Ground Potential Rise (GPR) by flowing fault currents to ground safely. There are several parameters which evaluate the performance of ground systems as ground resistance, touch voltage and step voltage. The touch and step voltages are especially important to ensure safety of human body. In this paper, we measured the touch and step voltages by injection of power frequency and surge current. Also correlation between touch and step voltages is compared and analyzed for the same ground systems.

  • PDF

가변주파수 인버터를 이용한 접지임피던스의 새로운 측정기법 (A Novel Method for Measuring the Ground Impedance using Variable Frequency Inverter)

  • 이복희;엄주홍
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.253-257
    • /
    • 2004
  • In order to analyze the frequency dependance of ground impedance in grounding grids for lightning and surge protection, a novel method for measuring the ground impedance as a function of frequency were experimentally investigated. The experiments were carried out in rectangular grounding grids with $6{\times}8$ conductors of 22 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the variable frequency inverter whose frequency is linearly controlled for the established period in the range of 5∼500 KHz. The amplitude and phase of ground impedance were calculated from the waveforms of the test current and ground potential rise measured by the band-pass filter tuned in a specific frequency. The frequency dependence of ground impedance was mainly caused by the inductive current flowing through grounding conductors over the frequency of 100 KHz. The proposed measurement method of ground impedance would be applicable to evaluate the transient response characteristics in lightning protection grounding systems.

직류전기철도 레일-대지간 절연저항 측정 방안 (Consideration of Conductance between Rails and Ground in DC Railway)

  • 한문섭;김주락;정호성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.166-168
    • /
    • 2008
  • DC feeding system is mainly floating but the rail potential and the leakage current are created because of long parallelism between rails and ground. Rail potential causes electric shock to human and leakage current causes electrolytic corrosion to nearby the buried metals. Therefore the design technologies to reduce, protect and monitor these effects are important recent DC feeding system. Rail potential and leakage current are analysed based on propagation theory that is utilized in order to simulate grounding system. New measurement procedure is proposed based on this analysis in order to more be accurate in result.

  • PDF

잠재성 특이산성토중 강관말뚝의 부식 (Steel Pile Corrosion in Potential Acid Sulfate Soil)

  • 이승헌;박미현;윤경섭
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.559-562
    • /
    • 2003
  • The results and discussions of surveyed case site at constructed steel pile in potential acid sulfate soil were as follows. Topography at surveyed site was local alluvial valley and that site soils was classified as BanGog and YuGye series as detailed soil surveyed results in RDA and soil texture was Clay/Clay Loam. Soils pH was neutral, which was average 7.5 but much decreased to average 4.2 after $H_2O_2$ treatment. Organic matter and sulfate ions contents were very rich. The corrosion was severe at ground water fluctuation depth. Deposits colored black were attached to steel pile surface, which because of violent reaction in treatment HCI solution, were guessed as corrosion products (FeS) reduced by sulfate reducing bacteria(SRB). Consequently, main cause was thought microbiologically induced corrosion at this site where there is ground water fluctuation occurring oxidation and reduction reactions in turn and the soil is potential acid sulfate soil.

  • PDF

Development of a Monitoring Equipment of Current and Potential on Power Transmission Line for 66kV

  • Nisiyama, Eiji;Kuwanami, Kenshi;Kawano, Mitsunori;Matsuda, Toyonori;Oota, I.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.41-44
    • /
    • 2003
  • We propose portable equipment that monitors current and voltage of high-potential power transmission lines. In the equipment, a current and voltage sensor are attached to an insulator that supports a power transmission line: A clamped to the power line and the detected current signal is transmitted to the ground station by a wireless optical link using transmission line is detected by a high resistance element, zinc oxide (ZnO). That acts as a potential divider between the power line and ground. We make an experimental device for 66kV power line and demonstrate that it can monitor currents proposed equipment is small-sized, light, and inexpensive in comparison with the conventional CT (current transformer) and PT (potential transformer) since it does not require high potential insulators and magnetic cores, further, the equipment is easily installed owing to its small size and its simple structure.

  • PDF

Assessment of seismic risk of a typical RC building for the 2016 Gyeongju and potential earthquakes

  • Jee, Hyun Woo;Han, Sang Whan
    • Earthquakes and Structures
    • /
    • 제20권3호
    • /
    • pp.337-351
    • /
    • 2021
  • On September 12, 2016, the Gyeongju earthquake occurred in the south-eastern region of the Korean peninsula. The event was ranked as the largest magnitude earthquake (=5.8) since instrumental recording was started by the Korean Metrological Administration (KMA) in 1978. The objective of this study is to provide information obtained from the 2016 Gyeongju earthquake and to propose a procedure estimating seismic risk of a typical old RC building for past and potential earthquakes. Ground motions are simulated using the point source model at 4941 grid locations in the Korean peninsula that resulted from the Gyeongju earthquake and from potential future earthquakes with the same hypocenter considering different soil conditions. Nonlinear response history analyses are conducted for each grid location using a three-story gravity-designed reinforced concrete (RC) frame that most closely represents conventional old school and public buildings. Then, contour maps are constructed to present the seismic risk associated with this building for the Gyeongju earthquake and potential future scenario earthquakes. These contour maps can be useful in the development of a mitigation plan for potential earthquake damage to school and public buildings at all grid locations on the Korean peninsula.

배전선로에서의 조가선 차폐 효과 연구 (A Study on a Shielding Effect of the Messenger Wires in Distribution Lines)

  • 김인수;한웅;여상민;김철환;원봉주;임용훈
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.431-436
    • /
    • 2009
  • As the telecommunication lines bring into widespread use, one of the most important aspects related to power distribution systems is effectively to evaluate the effect on the telecommunication lines from power lines. One of the efficient methods to evaluate the effect is to measure the induced voltage of a telecommunication line as a result of a ground-loop. If the power lines cause high induced voltage, the ground reference in the telecommunication lines is no longer a stable potential, so signals may ride on the noise. A ground loop is common wiring conditions where a ground current may take more than one path to return to the grounding electrode at the arrangement between the power lines and telecommunication lines. When a multi-path connection between the power lines and telecommunication line circuits exists, the resulting arrangement is known as a ground loop. Whenever a ground loop exists, there are potential for damages or abnormal operations of the telecommunication lines. The power lines can induce the voltage on the communication line. The effects can be calculated by considering the inductances and capacitances. However, if we assume that there are only power lines, it doesn't have a practical meaning because there are conductors with other purpose in the neighborhood of the lines. If we consider that case, we need more complex system. Therefore we suggest more complex system considering the conductors with other purpose in the neighborhood of the lines. The neutral wires and the overhead ground wires are considered for calculating the induced voltage. We assume that there are the messenger wires beside the power line as a result of increased use of them. The main purpose of this paper is a study on a shielding effect of messenger wires in the distribution lines. EMTP(Electro-Magnetic Transients Program) program is used for the induced voltage calculation.

Seismic fragility analysis of bridge response due to spatially varying ground motions

  • Kun, C.;Li, B.;Chouw, N.
    • Coupled systems mechanics
    • /
    • 제4권4호
    • /
    • pp.297-316
    • /
    • 2015
  • The use of fragility curves in the design of bridges is becoming common these days. In this study, experimental data have been used to develop fragility curves for the potential of girder unseating of a three-segment bridge and a bridge-abutment system including the influence of spatially varying ground motions, pounding, and abutment movement. The ground excitations were simulated based on the design spectra for different soil conditions. The Newmarket Viaduct replacement bridge in Auckland was used as the prototype bridge. These fragility curves were also applied to the 2010 Darfield and 2011 Christchurch earthquakes. The study showed that for bridges with similar characteristics as the chosen prototype and with similar fundamental frequencies, pounding could increase the probability of girder unseating by up to 35% and 30% based on the AASHTO and NZTA seating length requirements, respectively. The assumption of uniform ground excitations in many design practices, such as the NZTA requirements, could potentially be disastrous as girders might have a very good chance of unseating (as much as 53% higher chances when considering spatial variation of ground motions) even when they are designed not to. In the case of superstructures with dissimilar frequencies, the assumption of fixed abutments could significantly overestimate the girder unseating potential when pounding was ignored and underestimate the chances when pounding was considered. Bridges subjected to spatially varying ground excitations simulated based on the New Zealand design spectra for soft soil conditions with weak correlation shows the highest chances of girders falling off, of up to 65% greater than for shallow soil excitations.

Correlation of elastic input energy equivalent velocity spectral values

  • Cheng, Yin;Lucchini, Andrea;Mollaioli, Fabrizio
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.957-976
    • /
    • 2015
  • Recently, two energy-based response parameters, i.e., the absolute and the relative elastic input energy equivalent velocity, have been receiving a lot of research attention. Several studies, in fact, have demonstrated the potential of these intensity measures in the prediction of the seismic structural response. Although some ground motion prediction equations have been developed for these parameters, they only provide marginal distributions without information about the joint occurrence of the spectral values at different periods. In order to build new prediction models for the two equivalent velocities, a large set of ground motion records is used to calculate the correlation coefficients between the response spectral values corresponding to different periods and components of the ground motion. Then, functional forms adopted in models from the literature are calibrated to fit the obtained data. A new functional form is proposed to improve the predictions of the considered models from the literature. The components of the ground motion considered in this study are the two horizontal ones only. Potential uses of the proposed equations in addition to the prediction of the correlation coefficients of the equivalent velocity spectral values are shown, such as the prediction of derived intensity measures and the development of conditional mean spectra.

다양한 전류원에 대한 접지시스템의 위험전압 측정과 분석 (Measurement and Analysis of Risk Voltages by Various Current Sources in Grounding System)

  • 길경석;문병두;김황국;박대원;길형준
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.113-118
    • /
    • 2009
  • Grounding systems set the reference voltage level of electric circuits and suppress the Ground Potential Rise (GPR) by flowing fault currents to the ground safely. There are several parameters which evaluate the performance of grounding systems as ground resistance, touch voltage and step voltage. The touch and step voltages, which is called "risk voltage", are especially important to ensure the safety of human body. This paper dealt with the influence of current sources with the different frequency components on the touch and the step voltages. Three types of current sources as commercial frequency, square wave, and surge with the fast risetime of $50\;ns{\sim}500\;ns$ were used to analyze the risk voltages in a grounding system. The risk voltages showed remarkable difference in the same current amplitude depending on the current sources, and increased linearly with the current amplitude in the same current source. From the experimental results, it was confirmed that the risk voltages can be evaluated by a small current application in large-scale grounding systems and the possible largest risk voltage can be calculated by a surge current with the risetime of 200 ns or a current source with the same frequency component as the surge current.