• Title/Summary/Keyword: Ground loss

Search Result 861, Processing Time 0.032 seconds

A Study on Propagation Path Characteristics of GPS Potential Jamming Signal Based on Spherical Ground Diffraction Loss

  • Ko, Kwang-Soob
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.3
    • /
    • pp.264-269
    • /
    • 2013
  • This paper is to investigate propagation path characteristics of GPS potential jamming signal. To do this, the spherical ground diffraction model is applied to the potential jamming scenario referred to the GPS jamming events occurred in recent years. The fundamental theory on the propagation path loss is discussed and a specific model is applied to several vehicles types which have own heights of antennas in order to compare their propagation path loss values at same 2-D location. The transmitting powers are appropriately given as the ordinary GPS jamming events. And then the received powers in dBW are obtained with given transmitting powers and the estimated total loss. The result of received jamming power at various locations due to the given scenario was distinct. For example, propagation loss values were estimated as -147 ~ -142dBW and -167 ~ -162dBW in $10^6W$ and $10^4W$, respectively. This computation result of the loss can be seriously considered with the tolerable jammer power against L1- C/A GPS receiver under any real jamming situations.

Prediction Model of Propagation Path Loss of the Free Space in the Sea (해수면 자유공간의 전파경로손실 예측 모델)

  • 류광진;박창균
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.579-584
    • /
    • 2003
  • All of propagation path loss prediction models, which have been presented up to date, are oかy for ground living space. In reality, sea surface free space is different from ground living space in physical hierarchical structure. If the propagation path prediction model for ground living space is applied to the sea surface free space, propagation path loss will be smaller than actual value, while the maximum service straight line will become shorter. Thus this paper proposed and simulated the propagation path loss prediction model for predicting propagation path loss more accurately in sea surface free space, with its focus on CDMA mobile communication frequency band. Then the simulation results were compared to actual survey to verify its practicality.

Insertion Loss by Noise Barrier on the Discontinuous Ground (불연속 지면위의 방음벽에 의한 삽입손실에 관한 연구)

  • Kim, Ye-Hyun;Kim, Dong-Ill;Jang, Ho-Kyeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.114-121
    • /
    • 1995
  • Outdoor experimental study is presented the insertion loss caused by barrier considering discontinuous ground condition. Measurements ware made in 1/3 octave band over the frequency range 315 Hz~3150 Hz with the various geometry of the source, receiver and barriers. The frequency range of the interference pattern depends on the phase difference between path from the edge of barrier to receiver, and hence on the acoustical properties of the ground on the receiver side of the barrier. The insertion loss by barrier, in addition to diffraction, is shown to be dependent on the ground characteristic.

  • PDF

Case study of volume loss estimation during slurry tbm tunnelling in weathered zone of granite rock (화강풍화대를 통과하는 슬러리 TBM의 체적손실 산정에 대한 사례 연구)

  • Park, Hyunku;Oh, Ju-Young;Chang, Seokbue;Lee, Seungbok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.1
    • /
    • pp.61-74
    • /
    • 2016
  • This paper presents a case study on the ground settlement and volume loss estimation for slurry pressure balanced shield TBM tunnelling in weathered zone of granite rock. Settlement at each stage of shield tunnelling was analyzed and the volume losses and settlement trough factors were estimated from observations. In addition, using the existing volume loss evaluation method in literature, volume losses were estimated considering ground properties and actual driving parameters. Most of ground settlement occurred during passage of shield skin passage and after backfill grouting, and the measured total volume loss and trough curves appeared to coincide with literature. Shield and tail loss obtained from field measurement were found to be around 90% and 60% of the predictions, where tail loss indicated larger deviation than shield loss.

Analysis of pile group behaviour to adjacent tunnelling considering ground reinforcement conditions with assessment of stability of superstructures

  • Young-Jin Jeon;Cheol-Ju Lee
    • Geomechanics and Engineering
    • /
    • v.33 no.5
    • /
    • pp.463-475
    • /
    • 2023
  • Tunnel construction activity, conducted mainly in mountains and within urban centres, causes soil settlement, thus requiring the relevant management of slopes and structures as well as evaluations of risk and stability. Accordingly, in this study we performed a three-dimensional finite element analysis to examine the behaviour of piles and pile cap stability when a tunnel passes near the bottom of the foundation of a pile group connected by a pile cap. We examined the results via numerical analysis considering different conditions for reinforcement of the ground between the tunnel and the pile foundation. The numerical analysis assessed the angular distortion of the pile cap, pile settlement, axial force, shear stress, relative displacement, and volume loss due to tunnel excavation, and pile cap stability was evaluated based on Son and Cording's evaluation criterion for damage to adjacent structures. The pile located closest to the tunnel under the condition of no ground reinforcement exhibited pile head settlement approximately 70% greater than that of the pile located farthest from the tunnel under the condition of greatest ground reinforcement. Additionally, pile head settlement was greatest when the largest volume loss occurred, being approximately 18% greater than pile head settlement under the condition having the smallest volume loss. This paper closely examines the main factors influencing the behaviour of a pile group connected by a pile cap for three ground reinforcement conditions and presents an evaluation of pile cap stability.

Analysis of Ground Heat Loss in Ondol Heating Systems (온돌 난방에서의 지면을 통한 열손실)

  • Cho, Sung-Hwan;Kim, Kwan-Ho
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.7 no.3
    • /
    • pp.160-166
    • /
    • 1978
  • Heat loss to the ground in ondol heating system is analyzed mathematically using conformal mapping and variable transformations, Both two-and three-dimensional systems are analyzed. Heated house is assumed to be rectangular shape. Mean value of heat loss to the ground can be obtained using Figure 2. Effects of thermal parameters to heat loss are discussed. Numerical examples are also given.

  • PDF

Response Analysis of Nearby Structures with the Consideration of Tunnel Construction and Ground Conditions (터널시공 및 지반조건을 반영한 인접구조물의 거동분석)

  • Son, Moorak;Yun, Jongcheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6C
    • /
    • pp.255-263
    • /
    • 2010
  • This paper investigates the effects of tunnelling-induced ground movements on nearby structures, considering soil-structure interactions of different construction (ground loss) and soil characteristics. The response of four-story block structures, which are subjected to tunnelling-induced ground movements, has been investigated in different construction (ground loss) and soil conditions using numerical analysis. The structures for numerical analysis has been modelled using Discrete Element Method (DEM) to have real cracks when the shear and tensile stress exceed the maximum shear and tensile strength. The response of four-story block structures has been investigated with a ground movement magnitude and compared in terms of construction (ground loss) and soil conditions considering the magnitude of deformations and cracks in structures. In addition, the damage levels, which are possibly induced in structures, has been provided in terms of construction (ground loss) and soil conditions using the state of strain damage estimation criterion (Son and Cording, 2005). The results of this study will provide a background for better understandings for controlling and minimizing building damage on nearby structures due to tunnelling-induced ground movements.

Logistic Regression and GIS based Urban Ground Sink Susceptibility Assessment Considering Soil Particle Loss (토립자 유실을 고려한 로지스틱 회귀분석 및 GIS 기반 도시 지반함몰 취약성 평가)

  • Suh, Jangwon;Ryu, Dong-Woo;Yum, Byoung-Woo
    • Tunnel and Underground Space
    • /
    • v.30 no.2
    • /
    • pp.149-163
    • /
    • 2020
  • This paper presents a logistic regression and GIS based urban ground sink susceptibility assessment using underground facility information considering soil particle loss. In the underground environment, the particle loss due to water flow or groundwater level change leads to the occurrence and expansion of cavities, which directly affect the ground sink. Four different contributory factors were selected according to the two underground facility domains (water pipeline area, sewer pipeline area) and subway line area. The logistic regression method was used to analyze the correlation and to derive the regression equation between the ground sink inventory and the contributory factors. Based on these results, three ground sink susceptibility maps were generated. The results obtained from this study are expected to provide basic data on the area susceptible to ground sink and needed to safety monitoring.

Transient Heat Conduction Through the Ondol Floor and Beat toss to the Ground (온돌의 구들장과 땅바닥의 비정상 열전도 해석)

  • Bae, Soon-Hoon;Kim, Doo-Chun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.1
    • /
    • pp.6-17
    • /
    • 1975
  • For a periodic variation of the flue gas temperature the heat conduction through the Ondol floor was analysized. Also the heat loss to the ground was estimated. The floor thermal capacity, as a function of the floor thickness, has strong influence on the time lag of the temperature variation. It is an important design parameter for intermittent heating. Even for the steady periodic variation, there was significant heat loss to the ground below the Ondol floor.

  • PDF

Damage Assessment of Buried Pipelines Due to Tunnelling (터널 굴착에 의한 지중 매설관의 손상평가)

  • 유충식;윤효석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.471-478
    • /
    • 2000
  • Ground movements are inevitably caused by tunnel construction in soft ground. In the design and construction of tunnels in urban areas, the potential effects of buried pipelines by ground movements are one of the important design cosiderations. Generally, the most common modes of failure of buried pipelines due to ground movements are tensile fracture of main pipelines, rotation angle and pull-out displacement at joints. In the parametric study, a wide range of conditions were considered, including tunnel diameter(D), tunnel depth(Z$\sub$0/), volume loss(V$\sub$ι/) and inflection point(i). Based on this results, design charts, which are applicable to assess potential damage of buried pipelines associated ground movements due to tunnelling, are developed.

  • PDF