노면상태, 타이어 공기압 및 축하중이 조향력에 미치는 영향 (The Effect of Ground Condition, Tire Inflation Pressure and Axle Load on Steering Torque)

  • 박원엽;김성엽;이충호;최달문;이상식;이규승
    • Journal of Biosystems Engineering
    • /
    • 제29권5호
    • /
    • pp.419-424
    • /
    • 2004
  • In this study, a series of soil bin experiment was carried out to investigate experimentally the effect of the tire inflation pressure and axle load of tire on the steering torque for the off-road condition. The experiment was performed at the three levels of off-road conditions(ground I, ground II and ground III) and on-road condition(ground IV), four levels of tire inflation pressure(120 kPa, 170 kPa, 220 kPa and 270 kPa), and four levels of axle load(1470N, 1960N, 2450N and 2940N). The results of this study are summarized as follows: 1. Steering torque at the off-road conditions were higher than that on the on-road conditions for all levels of tire inflation pressure and axle load. 2. As the axle load increased, steering torque also increased f3r all experimental ground conditions. 3. For the axle load of 1470N the biggest steering torque was measured on the ground condition I, but as the axle load increased to the value of 2940N the biggest steering torque was measured on the ground condition III. From the above results, it was found that for the low axle load, steering torque gets higher on the soft ground condition, but for the high axle load, steering torque gets higher on hard ground condition for whole range of experimental conditions. 4. As the tire inflation pressure decreased, steering torque increased on the on-road condition, but no specific trend was not found at the off-road conditions.

쓰레기 매립층에서 그라운드 앵커의 극한하중 및 하중분포 (Ultimate Load and Load Distribution of Ground Anchor in Waste Landfill)

  • 김성규;조규완;김웅규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1434-1441
    • /
    • 2005
  • For anchored system applications, each ground anchor is tested after installation and prior to being put into service to loads that exceed the design. This load testing methodology, combined with specific acceptance criteria, is used to verify that the ground anchor can carry the design load without excessive deformations and that the assumed load transfer mechanisms have been properly developed behind the assumed critical failure surface. After acceptance, the ground anchor is stressed to a specified load and the load is locked-off. The two types of load tests conducted during the research program included performance test and creep test which were carried out in accordance with testing procedures by AASHTO(AASHTO 1990) and FHWA(Weatherby 1998) at Samsung-Dong 00 Site. Form the measurements, ultimate load and creep rate of anchors are proposed for straight shaft pressured grouted anchors in waste landfill. The load distribution on the grout was obtained from the measured strain data at each fraction of the ultimate load during the load tests.

  • PDF

지반-라이닝 상호작용 모델을 이용한 터널 2차라이닝 설계에 관한 연구 (A Study on Secondary Lining Design of Tunnels Using Ground-Lining Interaction Model)

  • 장석부;허도학;문현구
    • 한국터널지하공간학회 논문집
    • /
    • 제8권4호
    • /
    • pp.365-375
    • /
    • 2006
  • 일반적으로 터널2차라이닝의 구조해석에는 골조해석모델이 적용되고 있다. 본 모델은 경험적 방법에 의한 지반 이완하중을 고려하고 있으나 주관적이고 과대평가되는 경향이 있다. 2차라이닝에 작용하는 지반하중은 숏크리트 및 록볼트와 같은1차지보재의 지지력 상실에 기인한다. 그러므로 2차라이닝에 작용하는 지반하중 산정에는 1차지보재와 지반의 평형상태가 고려되어야 한다. 지반-라이닝 상호작용(Ground-Lining Interaction, GLI)모델은1차지보재의 지지력 상실에 의해 야기된 지반의 변형을2차라이닝이 지지하는 개념을 토대로 수립되었다. 따라서 GLI모델은 복잡한 지반조건과 1차 지보재의 설치조건을 합리적으로 반영한 지반하중을 고려할 수 있다. 2차라이닝에 작용하는 하중은 지반하중 외에 지하수압, 지진하중 등이 있다. 극한강도 설계법을 이용한 라이닝 구조보강을 위해서는 계수하중 및 다양한 하중조합이 고려되어야 한다. GLI모델은 계수하중을 고려하기 곤란하기 때문에 개별 하중에 대해 산정된2차라이닝 단면력에 하중계수를 곱하는 중첩의 원리를 적용하였다. 끝으로, 본 연구에서 제시된 GLI모델을 이용한 2차라이닝 설계방법을 저심도 지하철 터널에 적용하였다.

유한차분법을 이용한 말뚝의 하중전이특성 및 해석기법 (Analytical Technique and Load Transfer Features on Pile Using Finite Difference Method)

  • 한중근;이재호
    • 한국환경복원기술학회지
    • /
    • 제9권5호
    • /
    • pp.10-21
    • /
    • 2006
  • For analyze of the bearing capacity, skin friction and settlements of pile on axial compressive loading, both Load transfer tests of pile and pile loading test in field have application to commonly before pile installing. A bearing capacity of pile was affected by the characteristics of surrounding ground of pile. Especially, that is very different because of evaluation of settlement due to each soil conditions of ground depths. The ground characteristics using evaluation of bearing capacity of pile through load transfer analysis depends on N values of SPT, and then a bearing capacity of pile installed soft ground and refilled area may be difficult to rational evaluation. An evaluation of bearing capacity on pile applied axial compressive loading was effected by strength of ground installed pile, unconfined compressive strength at pile tip, pile diameter, rough of excavated surface, confining pressure and deformation modules of rock etc and these are commonly including the unreliability due to slime occurred excavation works. Load transfer characteristics considered ground conditions take charge of load transfer of large diameter pile was investigated through case study applied load transfer tests. To these, matrix analytical technique of load transfer using finite differential equation developed and compared with the results of pile load test.

미소 누전전류 검출 및 차단제어기 설계 (Development of Control Algorithm and Detection of the Small Leakage Current)

  • 반기종;김낙교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권3호
    • /
    • pp.161-165
    • /
    • 2004
  • In this paper, we have designed the ground faults detection and interrupting controller at normal condition of AC 120v to 240v rating voltage. Ground faults in electrical network have the characteristics of low current, 60㎐ frequency to 2㎑frequency. The load condition are no load and 20A load. The trip level of the controller is 6㎃ with ground faults. The Controller algorithm is implemented using pic16c71 microprocessor.

Three-dimensional finite element modelling and dynamic response analysis of track-embankment-ground system subjected to high-speed train moving loads

  • Fu, Qiang;Wu, Yang
    • Geomechanics and Engineering
    • /
    • 제19권3호
    • /
    • pp.241-254
    • /
    • 2019
  • A finite element approach is presented to examine ground vibration characteristics under various moving loads in a homogeneous half-space. Four loading modes including single load, double load, four-load, and twenty-load were simulated in a finite element analysis to observe their influence on ground vibrations. Four load moving speeds of 60, 80, 100, and 120 m/s were adopted to investigate the influence of train speed to the ground vibrations. The results demonstrated that the loading mode in a finite element analysis is reliable for train-induced vibration simulations. Additionally, a three-dimensional finite element model (3D FEM) was developed to investigate the dynamic responses of a track-ballast-embankment-ground system subjected to moving loads induced by high-speed trains. Results showed that vibration attenuations and breaks exist in the simulated wave fronts transiting through different medium materials. These tendencies are a result of the difference in the Rayleigh wave speeds of the medium materials relative to the speed of the moving train. The vibration waves induced by train loading were greatly influenced by the weakening effect of sloping surfaces on the ballast and embankment. Moreover, these tendencies were significant when the vibration waves are at medium and high frequency levels. The vibration waves reflected by the sloping surface were trapped and dissipated within the track-ballast-embankment-ground system. Thus, the vibration amplitude outside the embankment was significantly reduced.

Prediction of load transfer depth for cost-effective design of ground anchors using FBG sensors embedded tendon and numerical analysis

  • Do, Tan Manh;Kim, Young-Sang
    • Geomechanics and Engineering
    • /
    • 제10권6호
    • /
    • pp.737-755
    • /
    • 2016
  • The load transfer depth of a ground anchor is the minimum length required to transfer the initial prestressing to the grout column through the bonded part. A thorough understanding of the mechanism of load transfer as well as accurate prediction of the load transfer depth are essential for designing an anchorage that has an adequate factor of safety and satisfies implicit economic criteria. In the current research, experimental and numerical studies were conducted to investigate the load transfer mechanism of ground anchors based on a series of laboratory and field load tests. Optical FBG sensors embedded in the central king cable of a seven-wire strand were successfully employed to monitor the changes in tensile force and its distribution along the tendons. Moreover, results from laboratory and in-situ pullout tests were compared with those from equivalent case studies simulated using the finite difference method in the FLAC 3D program. All the results obtained from the two proposed methods were remarkably consistent with respect to the load increments. They were similar not only in trend but also in magnitude and showed more consistency at higher pullout loading stages, especially the final loading stage. Furthermore, the estimated load transfer depth demonstrated a pronounced dependency on the surrounding ground condition, being shorter in hard ground conditions and longer in weaker ones. Finally, considering the safety factor and cost-effective design, the required bonded length of a ground anchor was formulated in terms of the load transfer depth.

지반응답곡선을 이용한 지반과 지보재의 상호작용 분석 (Analysis on interaction of Ground and support using Ground response curve for tunnel design)

  • 안태훈;안성학;이송
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(II)
    • /
    • pp.1059-1064
    • /
    • 2002
  • The behavior of an opening and the performance of support system depend upon the load-deformation characteristics of ground and support as well as of the manner and of timing of support installation. The load-deformation characteristics of ground and support are derived by the interaction between ground and support. The interaction between ground and support is qualitatively illustrated by a ground response curve. The behavior of an opening and the performance of support system depend upon the load-deformation characteristics of ground and support as well as of the manner and of timing of support installation. The interaction between ground and support is qualitatively illustrated by a ground response curve. The convergence-confinement method don't need the basic assumptions for a mathematical model. Also This is applicable to general tunnel. Consequently the stability of tunnel must be qualitatively investigated by a ground response curve and quantitatively adjudged by a numerical analysis for the reasonable design of tunnel.

  • PDF

Monitoring of tension force and load transfer of ground anchor by using optical FBG sensors embedded tendon

  • Kim, Young-Sang;Sung, Hyun-Jong;Kim, Hyun-Woo;Kim, Jae-Min
    • Smart Structures and Systems
    • /
    • 제7권4호
    • /
    • pp.303-317
    • /
    • 2011
  • A specially designed tendon, which is proposed by embedding an FBG sensor into the center king cable of a 7-wire strand tendon, was applied to monitor the prestress force and load transfer of ground anchor. A series of tensile tests and a model pullout test were performed to verify the feasibility of the proposed smart tendon as a measuring sensor of tension force and load transfer along the tendon. The smart tendon has proven to be very effective for monitoring prestress force and load transfer by measuring the strain change of the tendon at the free part and the fixed part of ground anchor, respectively. Two 11.5 m long proto-type ground anchors were made simply by replacing a tendon with the proposed smart tendon and prestress forces of each anchor were monitored during the loading-unloading step using both FBG sensor embedded in the smart tendon and the conventional load cell. By comparing the prestress forces measured by the smart tendon and load cell, it was found that the prestress force monitored from the FBG sensor located at the free part is comparable to that measured from the conventional load cell. Furthermore, the load transfer of prestressing force at the tendon-grout interface was clearly measured from the FBGs distributed along the fixed part. From these pullout tests, the proposed smart tendon is not only expected to be an alternative monitoring tool for measuring prestress force from the introducing stage to the long-term period for health monitoring of the ground anchor but also can be used to improve design practice through determining the economic fixed length by practically measuring the load transfer depth.

계면요소를 이용한 지반-라이닝 상호작용 모델에 의한 터널 콘크리트 라이닝 연구 (A study of tunnel concrete lining design using the ground-lining interaction model with the interface element)

  • 허도학;문현구
    • 한국터널지하공간학회 논문집
    • /
    • 제17권6호
    • /
    • pp.575-586
    • /
    • 2015
  • NATM터널의 콘크리트 라이닝에 작용하는 지반하중을 산정하는 방법으로 수치해석적 기법인 지반-라이닝 상호작용모델(Ground-Lining Interaction Model, GLI 모델)에 의한 지반하중 산정방법이 제안되었다. 그러나, 기존의 GLI 모델은 지반과 지보재 또는 콘크리트 라이닝 사이에 존재하는 계면(Interface)의 구조적 역할을 반영하지 못하였다. 이에 본 연구에서는 기존의 GLI 모델에 계면요소를 반영하여 보다 실제에 가까운 모델로 구현하였다. 그리고, 지반조건 및 토피별 지반하중을 수치해석을 통해 산정하고 기존의 GLI모델 지반하중 상관식을 수정하여 제안하였다. 연구결과, 기존 모델에 비해 계면요소 반영시 지반하중은 토피두께에 따라 IV등급 지반조건에서는 평균 88~106%, 풍화토 지반조건에서는 평균 47~57% 수준으로 감소하였다. 본 연구결과로 콘크리트 라이닝에 작용하는 지반하중을 실제에 가까운 모델로 산정할 수 있으며, 상관식을 이용하여 일관되고 경제적인 설계가 가능하게 될 것으로 예상된다.