지중열교환기의 종류에 따른 열전달 성능에 관한 연구 (A study on the Heat Transfer Performance according to Ground Heat Exchanger Types)

  • 황석호;송두삼
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.75-80
    • /
    • 2010
  • Generally, ground-source heat pump (GSHP) systems have a higher performance than conventional air-source systems. However, the major fault of GSHP systems is their expensive boring costs. Therefore, it is important issue that to reduce initial cost and ensure stability of system through accurate prediction of the heat extraction and injection rates of the ground heat exchanger. Conventional analysis methods employed by line source theory are used to predict heat transfer rate between ground heat exchanger and soil. Shape of ground heat exchanger was simplified by equivalent diameter model, but these methods do not accurately reflect the heat transfer characteristics according to the heat exchanger geometry. In this study, a numerical model that combines a user subroutine module that calculates circulation water conditions in the ground heat exchanger and FEFLOW program which can simulate heat/moisture transfer in the soil, is developed. Heat transfer performance was evaluated for 3 different types ground heat exchanger(U-tube, Double U-tube, Coaxial).

지표수 및 지하수중 불소 함량에 관한 연구 (A Study on Fluoride Contents in Surface and Ground Waters in Korea.)

  • Kim, Sung-Ja;Noh, Pyung-Ui;Bak, Young-Soo
    • 한국환경보건학회지
    • /
    • 제3권1호
    • /
    • pp.9-12
    • /
    • 1976
  • A study was performed to find out the fluoride contents in surface and ground waters from June, 1973 to July, 1974. Water samples were collected from 53 surface and ground water sources. The results are as follows: 1. Out of 53 samples, the ground water of Hwaengsung had the highest fluoride contents (1.6 mg/l) and 13 samples did not. have fluoride at all. 2. The waters from Yoju (ground), Chongnung (ground) Hwaengsung (ground) and Namyang (ground) had optimum fluoride level (0.6~1.7mg/l) for the prevention of dental caries. 3. The ground waters had more fluoride contents than surface waters and the waters of coastal areas had less fluoride contents than those of inland. 4. The waters of Kangwon province had the most fluoride contents (mean 0.57mg/l) and the waters of Cheju do had the least fluoride contents (mean 0.06 mg/l)

  • PDF

지반 이완구간 추정을 위한 지하투과레이더의 적용 (Application of Ground Penetrating Radar for Estimation of Loose Layer)

  • 홍원택;강성훈;이종섭
    • 한국지반공학회논문집
    • /
    • 제31권11호
    • /
    • pp.41-48
    • /
    • 2015
  • 대규모 지반침하 및 지반함몰로 인한 재산, 인명피해를 사전에 예방하기 위하여 지반의 공동 및 이완구간에 대한 조사는 필수적이다. 최근, 지하투과레이더를 이용한 지반침하 및 지반함몰 구간 예측과 관련된 연구가 활발히 진행되고 있으나, 기존의 지하투과레이더 탐사에서는 전기적 임피던스가 서로 다른 층간 경계면 심도만을 산정하므로 조밀한 지반과 느슨한 지반을 서로 반대로 예측하는 오류를 범할 수 있었다. 본 연구에서는, 지하투과레이더로부터 획득된 전자기파의 반사파 특성을 이용하여 이완구간 심도를 추정하고자 하였다. 이완구간에 따른 신호획득을 위하여 과거 침하이력이 있었던 현장을 대상으로 지하투과레이더 탐사가 수행되었으며, 결과의 상호비교 및 검증을 위하여 동적 콘 관입시험이 수행되었다. 전자기파의 반사특성 분석 결과, 지하투과레이더 안테나에서 처음 측정된 신호와 조밀한 지반에서 반사되어 측정된 전자기파는 동일한 위상을 보이며, 느슨한 지반에서 반사되는 경우 안테나에서 처음 측정된 신호와 반대 위상을 보이는 것으로 나타났다. 획득된 지하투과레이더 신호로부터 대상지반의 이완구간 심도 산정 및 동적 콘 관입지수와 상호비교 결과, 지하투과레이더 신호 분석으로부터 산정된 이완구간 또는 조밀한 구간의 심도는 높은 신뢰도로 산정되었다. 본 연구에서 수행된 지하투과레이더 신호획득 및 분석과정은 지반 불연속층의 심도산정뿐만 아니라 이완구간 산정에 활용될 수 있을 것으로 판단된다.

층상구조에서 지진파 전파경로를 고려하여 수정된 경험 Green 함수를 이용한 지반운동 모사 (Site-Specific Ground Motions based on Empirical Green`s Function modified for the Path Effects in Layered Media)

  • 조남대;박창업
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.19-27
    • /
    • 2001
  • Seismic parameters fur computation of ground motions in Southern Korea are obtained from recently recorded data, and site-independent regional and site-dependent local strong ground motions are predicted using efficient computational techniques. For the computation of ground motions, we devised an efficient procedure to compute site-independent $x_{q}$ and dependent $x_{s}$ values separately. The first step of this procedure is to use the coda normalization method far computation of site independent Q or corresponding $x_{q}$ value. The next step is the computation of $x_{s}$, values fur each site separately using the given $x_{q}$ value. For computation of ground motions the empirical Green's function (EGF) is modified to account fur the depth and distance variations of subevents on a finite fault plane using the theoritical Green's function. It is computed using wavenumber integration technique in layered media. The site dependent ground motions at seismic stations in southeastern local area were properly simulated using the modified empirical Green's function method in layered medium. The proposed method and procedures fur estimation of site dependent seismic parameters and ground motions could be efficiently used in the low and moderate seismicity regions.ons.s.ons.

  • PDF

지열원 열펌프 시스템의 냉${\cdot}$난방 성능 평가 (Cooling and Heating Performance Evaluation of a GSHP System)

  • 손병후;조정식;신현준;안형준
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The main objective of the present study is to investigate the performance characteristics of a ground-source heat pump(GSHP) system with a 130 m vertical and 62 mm nominal diameter U-tube ground heat exchanger. In order to evaluate the performance analysis, the ground-source heat pump connected to a test room with $90\;m^2$ floor area in the Korea Institute of Construction $Technology(37^{\circ}39'N,\;126^{\circ}48'E)$ was designed and constructed. This ground-source heat pump system mainly consisted of ground heat exchanger, indoor heat pumps and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July 2, 2003 to July 1, 2004. The cooling and heating performance coefficients of the system were determined from the measured data. The average cooling and heating COPs for the system were obtained to be 4.90 and 3.96, respectively. The temperature variations in ground and the ground heat exchanger pipe surface at different depths were also measured.

국내 지중열전도도 측정 방법의 한계 및 개선 방향 (Limitations and improvement of the in situ measurements of ground thermal conductivity in Korea)

  • 심병완
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.195.2-195.2
    • /
    • 2011
  • The borehole heat exchanger of Geothermal Heat Pump (GHP) system should be sustainable and cost effective for long term operation. To guaranty the performance of the system thermal Response Tests (TRTs) with simple recommended procedures have been applied in many countries. Korea government developed a standard TRT procedure in order to control the quality on GHP projects. In the TRT procedure interpretation method has a rule that data set has to be interpreted by the line source model(LSM). The LSM employes some assumptions that surrounding medium is homogeneous and the line source is infinite and constant heat flux, however real ground condition is unisotropic and heterogeneous, and showing regional or local ground water flows in many cases. We need to develope improved evaluation models to estimate accurate ground thermal conductivity with respect to geological and influence of ground water because current TRT standard test procedure has limitations to be applied for every locations and system. This study surveyed the uncertainty of the thermal parameters from the interpretation method considering different evaluation period. The interpretation of 208 TRT data sets represents limitations of LSM application that some obtained ground thermal conductivities are statistically unstable and convergence time of ground thermal conductivity over test period shows trends responding the length of test period. This evaluation study will be helpful to provide some effective procedure for the thermal parameter estimation and to complement current TRT standard procedure.

  • PDF

김포국제공항의 GBAS 지상시험 및 성능 분석 (GBAS Ground Testing and Performance Analysis at Gimpo International Airport)

  • 정명숙;최윤정;윤영선;배중원;전향식;이영재
    • 한국항행학회논문지
    • /
    • 제19권1호
    • /
    • pp.22-32
    • /
    • 2015
  • 위성항법지역보강시스템(GBAS)은 항공기 정밀접근을 지원하는 차세대 항행안전무선시설로, 최근 GBAS 설치 및 서비스를 제공하는 공항들이 전 세계적으로 증가하고 있다. 한국도 2013년 김포국제공항에 국내 최초로 미국 Honeywell사의 GBAS 지상장비인 SLS-4000을 설치하였으며, 지상시험을 통해 설치된 장비의 기능 및 성능을 점검하였다. 본 논문에서는 GBAS 지상시험에 대한 국내 GBAS CAT-I 시험평가 기준 및 방법을 소개하고, 김포국제공항에서 진행된 GBAS 시험평가 방법에 대해 기술하였다. 또한 GBAS 지상시험의 12개 시험항목 중 주요 5개 시험항목에 대한 상세한 시험평가 방법 및 분석 결과를 기술하였다.

RELIABLE OPERATION IN COMS GROUND CENTERS

  • Lim, Hyun-Su;Ahn, Sang-Il
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.496-499
    • /
    • 2007
  • The COMS ground segment will operate the geostationary satellite continuously 24h/7days and deliver processed data to end-users with respect to the predefined schedule without delay. For reliable operation, each COMS ground center has internally dual-configuration for critical systems but impossible to every components. Any unexpected failure or regular maintenance to the single configured antenna system may lead the interruption of COMS service and operation. The natural disaster or external attack can destroy one ground center and the operation will be stopped. Therefore COMS program implements backup system remotely located in other centers. Even considering foreign geostationary systems, it's the best solution guaranteeing consistent system operation against internal failure or external disaster.

  • PDF

Acceleration amplification characteristics of embankment reinforced with rubble mound

  • Jung-Won Yun;Jin-Tae Han;Jae-Kwang Ahn
    • Geomechanics and Engineering
    • /
    • 제36권2호
    • /
    • pp.157-166
    • /
    • 2024
  • Generally, the rubble mound installed on the slope embankment of the open-type wharf is designed based on the impact of wave force, with no consideration for the impact of seismic force. Therefore, in this study, dynamic centrifuge model test results were analyzed to examine the acceleration amplification of embankment reinforced with rubble mound under seismic conditions. The experimental results show that when rubble mounds were installed on the ground surface of the embankment, acceleration response of embankment decreased by approximately 22%, and imbalance in ground settlement decreased significantly from eight to two times. Furthermore, based on the experimental results, one-dimensional site response (1DSR) analyses were conducted. The analysis results indicated that reinforcing the embankment with rubble mound can decrease the peak ground acceleration (PGA) and short period response (below 0.6 seconds) of the ground surface by approximately 28%. However, no significant impact on the long period response (above 0.6 seconds) was observed. Additionally, in ground with lower relative density, a significant decrease in response and wide range of reduced periods were observed. Considering that the reduced short period range corresponds to the critical periods in the design response spectrum, reinforcing the loose ground with rubble mound can effectively decrease the acceleration response of the ground surface.

표층처리된 초연약지반 거동에 대한 영향인자 분석 (Analysis of the effect factors on behavior of the surface reinforced very soft ground)

  • 유승경;이종선;양기석;조삼덕;함태규;최항석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.475-483
    • /
    • 2008
  • It is necessary to develop a national design method for surface reinforcement of very soft ground because most current design works rely on crude empirical correlations. In this paper, the mechanical behavior of very soft ground that is surficially reinforced was investigated with the aid of a sents of numerical analysis. Several material properties of each dredged soft ground, reinforcement and backfill sand mat have been exercised the numerical analysis in order to compare the result of numerical analysis with those of the laboratory model test. Through the matching process between the numerical and experimental result, it is possible to find the appropriate material properties of the dredged soft ground, reinforcements and backfill sand mat. These verified material properties permit to show the effect of the stiffness of reinforcement and the thickness of sand mat on the overall deformation.

  • PDF