• 제목/요약/키워드: Ground heat source

검색결과 307건 처리시간 0.025초

건물 기초를 이용한 지중열 공조시스템의 개발에 관한 연구 (1) (A Study on Development of a Ground-Source Heat Pump System Utilizing Pile Foundation of a Building)

  • 오오카 료죠;남유진;세키네 켄타로;요코이 무츠미;시바 요시로;황석호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.148-154
    • /
    • 2005
  • Ground-source (Geothermal) heat pump (GSHP) systems can achieve a higher coefficient of performance than conventional air-source heat pump (ASHP) systems. However, GSHP systems are not widespread in Japan because of their expensive boring costs. The authors have developed a GSHP system that employs the cast-in-place concrete pile foundations of a building as heat exchangers in order to reduce the initial boring cost. In this system, eight U-tubes are arranged around the surface of a cast-in-place concrete pile foundation. The heat exchange capability of this system, subterranean temperature changes and heat pump performance were investigated in a foil-scale experiment. As a result, the average values for heat rejection were 186${\sim}$201 W/m (for pile, 25 W/m per Pair of tubes) while cooling. The average COP of this system was 4.6 while cooling; rendering this system more effective in energy saving terms than the typical ASHP systems. The initial cost of construction per unit for heat extraction and rejection is ${\yen}$72/W for this system, whereas it is f300/W for existing standard borehole systems.

  • PDF

학교 건물에 설치된 지열원 열펌프 시스템의 실사용을 통한 냉난방성능 연구 (Cooling and Heating Performance Under the Actual Operating Condition of a Ground Source Heat Pump System in a School Building)

  • 김의영;정영만;송재도;이재근;김인규;이동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.586-589
    • /
    • 2009
  • This paper presents the performance of a water-to-refrigerant type ground source heat pump (GSHP) system installed in a school building in Korea. For analyzing the performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the input power of the GSHP system. The average cooling coefficient of performance (COP) of the heat pump was found to be 8.5 at 60% partial load condition, while the overall system COP was found to be 5.9. The average heating COP of the heat pump was found to be 6.5 at 45% partial load condition, while the overall system COP was found to be 5.0.

  • PDF

저심도 지중열교환기 개발을 위한 그라우트 재료에 따른 채열성능 검토 연구 (The Performance Analysis for Low-Depth Unit-type Ground Heat Exchanger According to Grouting Materials)

  • 오진환;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권2호
    • /
    • pp.7-11
    • /
    • 2015
  • Recently, as the demand for sustainable energy sources is increasing, ground-source heat pump (GSHP) systems are receiving growing attention. However, the initial cost of GSHP system is higher than it of the conventional systems, especially, in small-size buildings. Therefore, for the application to the small-size building, it is necessary to develop small-size ground heat exchanger with small-size buildings. In this study, analysis of unit-type heat exchanger due to grouting materials. As a result, 1492.14 W of heat exchange rate was acquired in the condition of cement-silica sand-graphite materials.

대형 Community 건물의 연료전지 구동 복합열원 하이브리드 히트펌프 냉.난방 시스템 성능 해석 (The Study on the Performance of the Fuel Cell Driven Compound Source Hybrid Heat Pump Heating and Cooling System to Large Community Building)

  • 변재기;정동화;최영돈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.82-87
    • /
    • 2007
  • In the present study, the simulation on the annual performance evaluation of a renewable energy systems with fuel cell driven compound source hybrid heat pump systems is applied to the heating and cooling of large community building. The large community building has the economical advantage to apply heat pump cooling and heating systems the long period operation. If air and ground source hybrid heat pump systems are combined, COP of the system can be increased largely. Fuel cell driven compound source hybrid heat pump system can reduced the fuel cost as well as thermal storage tank sharply.

  • PDF

직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가 (Evaluation of the Annual Performance of the Direct Expansion Vertical Closed-Loop Ground Source Heat Pump)

  • 김민성;우정선;백영진;장재철;김지영;라호상
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.534-542
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed-loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As a result, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

  • PDF

주거용 직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가 (Annual Performance Evaluation of Direct Expansion Vertical Closed-Loop Ground Source Heat Pump for Residential Application)

  • 김민성;백영진;라호상
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.114-122
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed -loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As results, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

지중열 이동 시뮬레이션을 이용한 수평형 지열시스템의 채열성능 예측 (Prediction of the Heat Exchange Rate for a Horizontal Ground Heat Pump System Using a Ground Heat Transfer Simulation)

  • 남유진;채호병
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.297-302
    • /
    • 2013
  • The ground source heat pump (GSHP) system has attracted attention, because of its stability of heat production, and the high efficiency of the system. However, there are few studies on the prediction method of the heat exchange rate for a horizontal GSHP system. In this research, in order to predict the performance of a horizontal GSHP system, coupled simulation with a ground heat transfer model and a heat exchanger circulation model was developed, and calculation of heat exchange rate was conducted by the developed tool. In order to optimally design the horizontal GSHP system, the flow rate of circulation water, and the depth and buried spaces of heat exchangers were considered by the case study. As a result, the temperature of circulation water and the heat exchange rate of the system were calculated in each case.

유출지하수 열원 지열히트펌프용 Pond Loop형 열교환기의 열전달 성능 (Heat Transfer Performance of Pond loop type Heat Exchanger for Ground Source Heat Pump using Extruding Ground Wafer)

  • 박근우;김진상;이응열
    • 신재생에너지
    • /
    • 제2권2호
    • /
    • pp.86-93
    • /
    • 2006
  • 유출지하수나 지표수를 열원으로 지열히트펌프의 지초자료로 활용하기 위하여 Pond Loop형 열교환기를 설계, 제작하여 유동이 없는 수조 내에서 수조의 온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량을 측정하였다. 그 결과 수조를 Heat Source로 사용하는 경우 $5,500{\sim}4,500kcal/h$의 열량이 전달되었고 수조를 Heat Sink로 사용할 경우 $5,200{\sim}3,500kcal/h$의 열량이 전달되었다. 또한 열교환기 관내 유속이 증가함에 따라 열전달량이 증가하는 경향성을 확인할 수 있었고 이는 동시에 열교환기 입출구의 차압을 증가시킴을 알 수 있었다. 열교환기의 설계단계에서 사용하였던 열전달관계식으로 구한 총괄열전달계수, U와 실험값을 통해 유추한 U값을 비교한 결과 실험에 의해 유추된 U값이 $24{\sim}27%$ 설계치보다 크게 나타났다. 본 연구를 통하여 유출지하수 뿐만 아니라 하수 및 하천수를 이용한 지열히트펌프의 기초자료를 확보할 수 있었다.

  • PDF

유출지하수 열원 지열히트펌프용 Pond Loop형 열교환기의 열전달 성능(2) (Heat Transfer Performance of Pond Loop type Heat Exchanger for Ground Source Heat Pump using Extruding Ground Water(2))

  • 박근우;이응열
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.15-19
    • /
    • 2006
  • 유출지하수나 지표수를 열원으로 하는 지열히트펌프의 Pond Loop형 열교환기를 개발하기 위하여 미국에서 상용화된 Slim-Jim 열교환기와 본 연구에서 자체설계, 제작한 Pond-loop type의 열교환기를 유동이 없는 유출수조 내에서 수조온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량의 변화를 측정하였다. 그 결과 유출수를 Heat Source로 사용하는 경우 Slim-Jim에서는 $8,000{\sim}11,000 kcal/hr$의 열량이 전달되었고, 자체 제작한 열교환기에서는 $11,000{\sim}16,000kcal/hr$의 열량이 전달되었다. 유출수를 Heat Sink로 사용할 경우 Slim-Jim에서는 $2,500{\sim}7,000 kcal/h$의 열량이 전달되었고, 자체제작한 열교환기의 경우, $6,800{\sim}14,00 kcal/hr$의 열량이 전달되었다. 측정된 열전달량을 바탕으로 총괄열전달계수를 구한 결과 Slim-Jim 열교환기의 경우 $210{\sim}340 kcal/hr\;m^2{\circ}C$, 자체개발한 열교환기의 경우 $350{\sim}590 kcal/hr\;m^2{\circ}C$로 나타나 자체 개발한 열교환기의 열전달 성능이 비교적 우수함을 입증하였다.

  • PDF

유출지하수 열원 지열히트펌프용 Pond Loop형 열교환기의 열전달 성능 (Heat Transfer Performance of Pond Loop type Heat Exchanger for Ground Source Heat Pump using Extruding Ground Water)

  • 박근우;김진상;이응열
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.445-450
    • /
    • 2006
  • 유출지하수나 지표수를 열원으로 하는 지열히트펌프의 기초자료로 활용하기 위하여 Pond Loop형 열교환기를 설계, 제작하여 유동이 없는 수조 내에서 수조의 온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량을 측정하였다. 그 결과 수조를 Heat Source로 사용하는 경우 $5,500{\sim}4,500kcal/h$의 열량이 전달되었고, 수조를 Heat Sink로 사용할 경우 $5,200{\sim}3,500 kcal/h$의 열량이 전달되었다. 또한 열교환기 관내 유속이 증가함에 따라 열전달량이 증가하는 경향성을 확인할 수 있었고, 이는 동시에 열교환기 입출구의 차압을 증가시킴을 알 수 있었다. 열교환기의 설계단계에서 사용하였던 열전달관계식으로 구한총괄열전달계수, U와 실험값을 통해 유추한U값을 비교한 결과 실험에 의해 유추된 U값이 $24{\sim}27%$ 설계치보다 크게 나타났다. 본 연구를 통하여 유출지하수 뿐만 아니라 하수 및 하천수를 이용한 지열히트펌프의 기초자료를 확보할 수 있었다.

  • PDF