References
- Park, J. I. and Park, K. S., 2013, Study on capacity alteration of geothermal heat exchanger by changing design condition, Journal of KSGEE, Vol. 9, No. 4, pp. 8-13.
- Son, B. H., 2012, Effect of soil thermal conductivity and moisture content on design length of horizontal ground heat exchanger, Journal of KSGEE, Vol. 8, No. 1, pp. 21-31.
- Kim, E. J., 2014, Impact of different boundary conditions in generating g-function on the sizing of ground heat exchangers, Journal of SAREK, Vol. 26, No. 6, pp. 263-268.
- Cho, J. H. and Nam. Y. J., 2015, A study on the characteristics of heat source temperature for twowell geothermal system using numerical simulation, Journal of SAREK, Vol. 27, No. 4, pp. 207-212.
- Gerber, L. and Marechal, F., 2012, Defining optimal configurations of geothermal system using process design and process intergration techniques. Applied Thermal Engineering, Vol. 43, pp. 29-41. https://doi.org/10.1016/j.applthermaleng.2011.11.033
- Chen, M., Tompson, A. F. B., Mellors, R. J., and Abdalla, O., 2015, An efficient optimization of well placement and control for a geothermal prospect under geological uncertainty, Applied Energy, Vol. 137, pp. 352-363. https://doi.org/10.1016/j.apenergy.2014.10.036
- Lamarche, L., Kajl, S., and Beauchamp, B., 2010, A review of methods to evaluate borehole thermal resistances in geothermal heat-pump systems, Geothermics, Vol. 39, pp. 187-200. https://doi.org/10.1016/j.geothermics.2010.03.003
- Elisabeth, S., Thomauske, K., Schmalzbauer, J., Herberger, S., Gebert, C., and Velevska, M., Design and test of a new flow calorimeter for online detection of geothermal water heat capacity, Geothermics, Vol. 53, pp. 202-212.
- Chen, J., Xia, L., Li, B., and Mmereki, D., 2015, Simulation and experimental analysis of optimal buried depth of the vertical U-tube ground heat exchanger for a ground-coupled heat pump system, Renewable Energy, Vol. 73, pp. 46-54. https://doi.org/10.1016/j.renene.2014.06.007
- Mohamed, O., Parham, E. N., Zine, A., and Louis, L., 2014, Analysis of the convective heat exchange effect on the undisturbed ground temperature, Solar Energy, Vol. 108, pp. 340-347. https://doi.org/10.1016/j.solener.2014.07.015
- Huang, S., Ma, Z., and Cooper, P., 2014, Optimal design of vertical ground heat exchangers by using entropy generation minimization method and genetic algorithms, Energy Conversion and Management, Vol. 87, pp. 128-137 https://doi.org/10.1016/j.enconman.2014.06.094
- Oh, J. H., Seo, J. H., and Nam, Y. J., 2015, Performance analysis of a low-depth unit-type ground heat exchanger using numerical simulation, Journal of SAREK, Vol. 27, No. 3, pp. 169-173.
- Nam, Y. J., 2011, Numerical analysis for the effect of ground and groundwater conditions on the performance of ground source heat pump systems, Journal of SAREK, Vol. 23, No. 5, pp. 321-326.
- Nam, Y. J., Ooka, R., and Hwang, S. H., 2008, Development of a numerical model to predict heat exchange rates for a ground-source heat pump system, Energy and Buildings, Vol. 40, pp. 2133-2140. https://doi.org/10.1016/j.enbuild.2008.06.004
- Lee, C. H., Park, M. S., Min, S. H., Kang, S. H., Sohn, B. H., and Choi, H. S., 2011, Comparison of effective thermal conductivity in closed-loop vertical ground heat exchangers, Applied Thermal Engineering, Vol. 31, pp. 3669-3676. https://doi.org/10.1016/j.applthermaleng.2011.01.016