고성능저가형 지중열교환기 개발연구 (Development of High Peformance Geothermal heatexchanger)

  • 안형준;백성권;임성균
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.470-473
    • /
    • 2007
  • Geothermal heat exchanger(GHEX) is a major component of Geothermal heat pump system(GSHPs). In Common, We use the vertical type GHEX in Korea. But vertical type GHEX needs a high cost for installation, because of drilling the hole which has 200m depth at max. So, We suggest the use of horizontal type GHEX. When we construct buildins, We excavate the ground and we can install the horizontal type GHEX at the excavated underground. It's very cheap and convenient method compare to vertical type GHEX installation. This study is peformed to estimate the peformance of horizontal type GHEX and to analyze effects of heat exchanger types and undergroundwater. As the result, slinky type GHEX has a 66% efficiency compare to vertical type GHEX and mat type has a 201% efficiency at the undergroundwater zone.

  • PDF

수직밀폐형 지중열교환기의 회로 과도해석 상사모델 개발 (Development of an Electric Circuit Transient Analogy Model in a Vertical Closed Loop Ground Heat Exchanger)

  • 김원욱;박홍희;김용찬
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.306-314
    • /
    • 2012
  • Several numerical or analytical models have been proposed to analyze the thermal response of vertical ground heat exchangers (GHEX). However, most models are valid only after several hours of operation since they neglect the heat capacity of the borehole. Recently, the short time response of the GHEX became important in system simulation to improve efficiency. In this paper, a simple new method to evaluate the short time response of the GHEX by using an analogy model of electric circuit transient analysis was presented. The new transient heat exchanger model adopting the concept of thermal capacitance of the borehole as well as the steady-state thermal resistance showed the transient thermal resistance of the borehole. The model was validated by in-situ thermal response test and then compared with the DST model of the TRNSYS program.

설계변수가 수직밀폐형 지중열교환기 설계길이에 미치는 영향 (Effect of the Design Parameters of Geothermal Heat Exchanger Design Length)

  • 민경천;최재호
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.10-15
    • /
    • 2011
  • A ground loop heat exchanger for the ground source heat pump system is the core equipment determining the thermal performance and initial cost of the system The length and performance of the heat exchanger is dependent on the ground thermal conductivity, the operation hours, the ground loop diameter, the grout, the ground loop arrangement, the pipe placement and the design temperature. The result of this simulation shows that higher thermal conductivity of grouting materials leads to the decrease length of geothermal heat exchanger from 100.0 to 84.4%.

수직형 지열교환기의 입.출구온도에 대한 실측과 CFD 결과 비교 (The Comparison of the EWT&LWT between Field Measurement and CFD of Vertical-type Geothermal Heat Exchanger)

  • 우상우;김중헌;신승호;황광일
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권1호
    • /
    • pp.11-16
    • /
    • 2007
  • The purpose of this study is to use the CFD(Computational Fluid Dynamics) method for the ground source heat pump(GSHP) system with vertical U-tube ground heat exchangers. In order to predict LWT(leaving water temperature) in the length of time, This simulation is used by utilizing FLUENT which is commercial CFD code. It was performed by based on four boreholes in the field. Comparing with the results of CFD and field measurement for LWT, the results of CFD was presented very good agreement with 1.0% average difference.

  • PDF

병렬 U형 현장타설 에너지파일의 열교환 효율 및 적용성 평가 (Evaluation of Heat Exchange Efficiency and Applicability for Parallel U-type Cast-in-place Energy Pile)

  • 박상우;김병연;성치훈;최항석
    • 대한토목학회논문집
    • /
    • 제35권2호
    • /
    • pp.361-375
    • /
    • 2015
  • 에너지파일은 기존의 수직밀폐형 지중열교환기를 경제적으로 대체할 수 있는 새로운 형태의 지중열교환기이다. 즉, 에너지파일은 건물의 기초 구조물과 지중열교환기의 역할을 동시에 수행하는 에너지 구조체로서, 말뚝 기초 내부에 열교환 파이프를 삽입하고 파이프를 통해 유체를 순환시켜 지반과의 열교환을 유도한다. 본 연구에서는 병렬 U형(5쌍, 8쌍, 10쌍)의 열교환 파이프를 대구경 현장타설 에너지파일에 삽입하여, 3본의 에너지파일을 실규모로 시공하였다. 또한 현장 열응답 시험(In-situ thermal response tests, TRTs)을 수행하고 시공된 현장타설 에너지파일과의 열교환 효율을 비교하기 위하여 30m 깊이의 수직밀폐형 지중열교환기를 별도로 시공하였다. 병렬 U형 현장타설 에너지파일에 대해서는 냉난방 부하를 인공적으로 주입하는 열교환 성능 평가시험을 수행하여 열교환 성능(heat exchange rate)을 평가하였다. 마지막으로 현장타설 에너지파일의 적용성 평가를 위해 산정된 상대 열교환 효율(relative heat exchange efficiency) 및 열교환 성능을 선행 연구 결과와 비교하였으며, 본 연구에서 시공된 현장타설 에너지파일은 안정적이고 효율적인 열성능을 보이는 것으로 나타났다.

파이프 재질 및 형태에 따른 에너지 슬래브의 현장 열교환 성능 평가 (Evaluation on in-situ Heat Exchange Efficiency of Energy Slab According to Pipe Materials and Configurations)

  • 이석재;오광근;한신인;박상우;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.1-7
    • /
    • 2017
  • The energy slab is a ground coupled heat exchanger equipped in building slab structures, which represents a layout similar to the horizontal ground heat exchanger (GHEX). The energy slab is installed as one component of the floor slab layers in order to utilize the underground structure as a hybrid energy structure. However, as the energy slab is horizontally arranged, its thermal performance is inevitably less than the conventional vertical GHEXs. Therefore, stainless steel (STS) pipes are alternatively considered as a heat exchanger instead of high density polyethylene (HDPE) pipes in order to enhance thermal performance of GHEXs. Moreover, not only a floor slab but also a wall slab can be utilized as a heat-exchangeable energy slab in order to maximize the use of underground space effectively. In this paper, four field-scale energy slabs were constructed in a test bed, which consist of the STS and HDPE pipe, and a series of thermal response tests (TRTs) was conducted to evaluate relative heat exchange efficiency per unit pipe length according to the pipe material and the configuration of energy slabs. The energy slab equipped with the STS pipe shows higher thermal performance than the energy slab with the HDPE pipe. In addition, thermal performance of the wall-type energy slab is almost equivalent to the floor-type energy slab.

수주지열정(SCW)을 이용한 천부지열 냉난방시스템 설계지침 (Design Guidlines of Geothermal Heat Pump System Using Standing Column Well)

  • 한정상;한혁상;한찬;김형수;전재수
    • 자원환경지질
    • /
    • 제39권5호
    • /
    • pp.607-613
    • /
    • 2006
  • 내 수문지열계 가운데 수주지열정(SCW)시스템을 합리적으로 설치이용할 수 있는 조건들은 심도별 지온증가율이 명확하고($2^{\circ}C/100m$심도), 기존의 지하수 열펌프가 필요로 하는 순환수의 유량에 비해 최소 $10{\sim}30%$의 중온의 심부지하수가 산출될 수 있어야 하며, 순환수를 공내로 재주입시 공내붕괴가 일어나지 않는 견고한 암석들이 존재 하여야 한다. 수주지열정의 1개공당 굴착심도는 평균 $400{\sim}500m$이며, 이로 부터 개발가능한 지열에너지는 공당 약 $30{\sim}40RT$ 규모인데 비해 1개 수직지중열교환기가 공급가능한 지열에너지는 $2{\sim}3RT$ 정도이다. 즉 수주지열정 1개공은 $10{\sim}15$개의 수직지중열교환기 역할을 한다. 따라서 이 방식은 수직루프 설치장소의 공간 문제를 해소할 수 있는 유일한 대안으로 인식되어, 현재 전국 각지에서 많은 수의 SCW들이 무분별 하게 비과학적으로 설치되고 있다. 이와 같이 해당지역 수문지열계의 수리 지질학적인 특성과 열적인 특성을 명확히 파악하지 않은 상태에서 수주지열정을 설계 시공하는 경우에 나타날 문제점들은 추후 합리적인 천부지열 개발 이용에 지대한 장애요인이 될 것이다. 따라서 본고는 국내 수문지열계에 적합한 수주지열정을 설계 하는데 있어 필요한 일종의 지침서를 제시하기 위해 작성되었다.

대구경 현장타설 에너지파일의 열교환 성능과 시공성 및 경제성 분석 (Evaluation on Thermal Performance Along with Constructability and Economic Feasibility of Large-diameter Cast-in-place Energy Pile)

  • 박상우;성치훈;이동섭;정경식;최항석
    • 한국지반공학회논문집
    • /
    • 제31권5호
    • /
    • pp.5-21
    • /
    • 2015
  • 에너지파일이란 새로운 형식의 지중열교환기로서, 건물의 기초 구조물인 말뚝 내부에 열교환 파이프를 삽입하고 파이프 내부로 유체를 순환시켜 지반과 말뚝 매질사이의 열교환을 유도한다. 에너지파일은 기존의 기초 구조물을 활용하여, 구조물의 지지 기능과 지중열교환기로서의 기능을 동시에 수행하는 에너지 구조체이다. 본 연구에서는 에너지파일의 실증연구를 위하여 총 6가지 형태의 열교환 파이프가 삽입된 실규모 현장타설 에너지파일을 시험 시공하였다. 열교환 파이프의 형태는 다양한 형태별 성능 및 시공성 비교를 위해 병렬 U형 3본(5쌍, 8쌍, 10쌍), 코일형 2본(피치간격 200mm와 500mm), S형 1본으로 선정하였다. 총 6가지 형태의 열교환 파이프를 시공하면서 시공 소요시간, 인력 소요, 필요 부대시설, 특이사항 등을 정리하여 각 형태별 시공성을 평가하였다. 또한 시공된 현장타설 에너지파일에 대한 열교환 성능 평가시험을 수행하였다. 열교환 성능 평가시험은 실제 상업 건물의 냉방 부하를 모사하기 위하여 8시간 가동 16시간 휴지의 간헐적 가동을 통하여 수행하였다. 열교환 성능 평가시험 결과를 통하여 각 현장타설 에너지파일의 열교환량을 산정하였으며, 이를 에너지파일 근입 깊이 및 열교환 파이프 길이로 정규화하여 각 형태별 열교환 효율을 평가하였다. 마지막으로 현장타설 에너지파일의 경제성을 분석하기 위하여 각 형태별 에너지파일의 시공비와 에너지파일 단위 길이 당 열교환 성능을 통해 1W/m 당 소요 비용을 산정하였다.

에너지 슬래브의 열-역학적 수치해석 모델 개발 (Development of Thermomechanical Coupled Numerical Model for Energy Slab)

  • 박상우;최항석;이석재
    • 한국지반공학회논문집
    • /
    • 제40권1호
    • /
    • pp.55-63
    • /
    • 2024
  • 본 연구에서는 에너지 슬래브의 안정성을 검토하기 위해 열-역학적 수치해석 모델을 개발하였다. 먼저, 주거용 건물 지하주차장에 벽체형 에너지 슬래브를 설치한 뒤 현장 열성능 평가시험(Thermal performance test, TPT)을 수행하였다. 이를 기반으로 현장 열성능 평가시험의 열-수리학적 거동을 정교하게 모사할 수 있는 에너지 슬래브의 열-수리학적 수치해석 모델을 개발하였다. 마지막으로, 열-수리학적 모델을 통해 도출된 시간-온도 데이터를 기반으로 에너지 슬래브의 열-역학적 수치해석 모델을 개발하였다. 개발된 모델을 기반으로 에너지 슬래브의 운용에 따른 열응력을 산정한 결과 최대 5,300kPa의 열응력이 발생하였으며, 이는 에너지 슬래브의 안정적인 운용을 위해 충분한 인장강도가 확보된 시멘트 몰탈 활용이 필요하다는 것을 시사한다.