• 제목/요약/키워드: Ground fault protection

검색결과 91건 처리시간 0.032초

동기 발전기의 평형 및 불평형 고장해석 (Balanced and Unbalanced Fault Analysis of Synchronous Generator)

  • 박철원;안준영;이종수;이상성;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.402-404
    • /
    • 2006
  • In this paper, we simulated transient-state under fault in stator windings of synchronous generator. The fault types are line to ground fault, line to line short fault, and three phase short fault. For fault analysis of generator system, the voltage equation of a synchronous machine using the two-axis theory was used. It can be used to analyze important features of faults and to develop enhanced protection methods.

  • PDF

New Fault Location Algorithms by Direct Analysis of Three-Phase Circuit Using Matrix Inverse Lemma for Unbalanced Distribution Power Systems

  • Park, Myeon-Song;Lee, Seung-Jae
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.79-84
    • /
    • 2003
  • Unbalanced systems, such as distribution systems, have difficulties in fault locations due to single-phase laterals and loads. This paper proposes new fault locations developed by the direct three-phase circuit analysis algorithms using matrix inverse lemma for the line-to-ground fault case and the line-to-line fault case in unbalanced systems. The fault location for balanced systems has been studied using the current distribution factor, by a conventional symmetrical transformation, but that for unbalanced systems has not been investigated due to their high complexity. The proposed algorithms overcome the limit of the conventional algorithm using the conventional symmetrical transformation, which requires the balanced system and are applicable to any power system but are particularly useful for unbalanced distribution systems. Their effectiveness has been proven through many EMTP simulations.

일점접지방식을 이용한 전자교환기 방호의 실제 (Engineering Practice for ESS Protection by means of One Point Grounding System)

  • 김수형;서정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.502-505
    • /
    • 1988
  • This paper is to demonstrate the effectiveness of one point grounding in support of ESS protection. One point grounding provides for the dispatching of excess energy for protection of switching equipment and personnel from lightning discharge hazards and for a natural sink for noise from atmospheric lightning and power transients. In most ESS installations there are a number of different items that must be maintained at a common ground potential for safety, fault protection or noise reduction. The items typically consist of power systems, heating and ventilating systems, distributing frames, repeating equipmets, switching equipments, etc. Grounding system of an ESS Office is most effective when all the ground points are connected to a single, common earth. The one point grounding prvides a common reference potential, keeping all the items of telecommunications facility free from the earth current and voltage hazards.

  • PDF

전기철도 급전시스템의 매설접지 방식 유용성 평가 (Evaluation of Efficiency for Grounding System on the Electrified Railways)

  • 창상훈;한문섭;이장무;이형수;김정훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.86-92
    • /
    • 2000
  • Recently, the Korea National Railways (KNR) is undertaking a program of electrification of the existing railway routes. In order to implement the ongoing plan, KNR authorized a preliminary engineering study of its electrical systems. This effort included a comprehensive analysis of new grounding networks. The new grounding system runs in parallel with the rails and is connected to all metal structures such as rails, overhead protection wires and substation grounding grids etc., creating an equipotential ground network. This paper presents a study on coupling levels that can disturb signaling and telecommunications in adoption of the new grounding network The simulation for the study is carried out using Matlab software, Several different scenarios are analyzed, including the load condition and a few fault conditions with different fault locations. The induced potentials on the communication cables are computed. The effect of the buried ground wires is also analyzed by comparing the results with and without the presence of the ground wires, The results presented in the paper can be used as a reference for estimating coupling levels in similar rail systems.

  • PDF

765kV 비연가 송전계통 과도 특성에 관한 고찰 (A Study on the Transient Characteristics in 765kV Untransposed Transmission Systems)

  • 안용진;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권7호
    • /
    • pp.397-404
    • /
    • 2004
  • This paper describes a study of transient characteristics in 765kV untransposed transmission lines. As the 765(kV) system can carry bulk power, some severe fault on the system nay cause large system disturbance. The large shunt capacitance and small resistance of 765kv transmission line make various difficulties for its protection. These problems including current difference between sending and receiving terminals on normal power flow, low order harmonic current component in fault current and current transformer saturation due to the long DC time constant of the circuit etc. must be investigated and solved. The analysis of transient characteristics at sending terminal has been carried out for the single phase to ground fault and 3-phase short fault, etc. The load current, charging current in normal condition and line flows, fault current, THD(Total Harmonic Distortion) of harmonics, time constants have been analysed for the 765kV untransposed transmission line systems.

OF 케이블 계통에서 과도상태시 에너지 특성 검토 (A Study on Energy Characteristics in Transient States of OF Cable Systems)

  • 정채균;이종범;강지원;이동일;서재호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권11호
    • /
    • pp.468-475
    • /
    • 2006
  • This paper reviews the energy characteristics of oil filled cables in transient state such as grounding fault and lightning surge. Artificial grounding fault test was firstly performed in 2003 for the analysis of arc voltage and breakdown energy according to the fault current. In this paper, energy of OF cable is variously analysed at joint box based on the actual test. Then more various conditions such as installation types, section lengths and CCPU(Cable Covering Protection Unit) connection types are applied for the simulation using EMTP when the single line to ground fault and direct lightning stroke are occurred on actual underground power cable systems and combined power cable systems, respectively. Finally, the energy by the length of crossbonded lead and grounding lead as well as fault lasting time is also calculated using EMTP simulation.

직류 비접지계통에서 절연저항측정장치(IMD)를 이용한 사고검출 알고리즘 (Algorithm of Detecting Ground Fault by Using Insulation Monitoring Device(IMD) in Ungrounded DC System)

  • 김기영;이후동;태동현;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.528-535
    • /
    • 2020
  • 최근 신재생에너지 및 분산전원의 급속한 보급과 직류부하의 증가로 인하여 직류급전에 대한 관심이 높아지고 있으며, 이에 대한 보호협조방식에 대한 연구가 활발히 이루어지고 있다. 그러나 직류급전방식을 사용하는 기존의 직류 부하망과 도시철도 등은 비접지방식인 IT 접지 시스템으로서 지락고장발생 시 고장전류의 경로가 없고, 정상상태 전류에 비하여 큰 차이가 발생하지 않기 때문에 지락고장검출이 어려운 실정이다. 따라서 본 논문에서는 절연저항측정장치(IMD : Insulation Monitoring Device)를 직류 비접지계통의 보호기기로 활용하기 위하여, IMD의 검출원리를 정식화한다. 이를 바탕으로 IMD의 신호주입방식에 의한 출력 값을 웨이블릿변환기법으로 분석하여, 사고검출을 신속하고, 정확하게 판단할 수 있는 검출알고리즘을 제안한다. 또한, 상용전력 계통해석프로그램인 PSCAD/EMTDC를 이용하여, 직류 비접지계통과 IMD를 모델링하고, MATLAB을 이용한 웨이블릿변환 수치해석모델링을 수행한다. 이를 바탕으로 직류 비접지계통의 지락사고를 해석한 결과, 본 논문에서 제안한 IMD의 사고검출 알고리즘의 유효성을 확인하였다.

접지규정 IEC 60364의 국내 적용을 위한 실증시험장 구축 (Test field for the application of IEC 60364 in Korea)

  • 남기영;최상봉;류희석;이재덕;정성환;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.116-118
    • /
    • 2005
  • IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standards deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries defines the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for themselves. The background of circuit of IEC 60364 is based on the ungrounded system as most of European countries adopt. However, since domestic ground system is multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364 and to evaluate the standard is applicable or not to domestic rule for the protection against ground fault through the related test.

  • PDF

배전시스템에 연계된 다기능 전지전력저장시스템의 사고에 관한 연구 (A Study on Fault of Multifunctional Battery Storage System interconnected with Distribution System)

  • 김재철;문선호;김인택;김응상;추동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1244-1246
    • /
    • 1998
  • This paper present a variety fault problem brought out with the multifunctional Battery Energy Storage System [MBESS] expected to be practical in the short future interconnected to power distribution system. Multifunctional BESS model and interconnection model to power system is simply configured, the problems of protection coordination and operation is studied. A line fault in the power distribution system are discussed such as line to ground and three phase fault in order to show the impact on power utilities, demand-side and BESS-side. In order to simulate a variable transient phenomenon due to 2 the BESS interconnection operation to power distribution system, in this paper, PSCAD/EMTDC simulation tools is used.

  • PDF

22.9kV 중성점 다중접지계통에 CD형 초전도케이블을 적용한 경우의 지락전류변화 (Ground fault current variation of 22.9kV CD type superconducting cable system)

  • 이근준;이상한;손송호;황시돌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.46-47
    • /
    • 2006
  • 본 논문은 CD형 초전도 케이블을 22.9kV 다중접지 배전계통에 적용한 경우 불평형 지락 고장이 초전도 케이블에 미치는 영향을 검토하고 이로 인한 중성선 전류의 변화 및 계통보호를 위한 대책을 논한다. 3상 CD형 초전도 케이블을 사용하는 경우 귀로선은 전향선과 전류가 반대이면서 거의 동일한 전류가 흐르므로 회로의 인덕턴스를 크게 줄일 수 있지만 이를 위해 회로를 단락하여 운전하는 경우 지락고장시 영상회로가 별도로 존재하지 않으면 지락전류를 저감시키는 결과를 초래하게 되어 계통보호에 영향을 주게 된다. 본 논문은 EMTDC 프로그램을 활용하여 이 현상을 XLPE 케이블 계통과 비교, 모의하는 한편, 정상적인 보호계전기 동작이 가능토록 하는 대책에 대해 논한다.

  • PDF