• Title/Summary/Keyword: Ground fault protection

Search Result 91, Processing Time 0.026 seconds

Balanced and Unbalanced Fault Analysis of Synchronous Generator (동기 발전기의 평형 및 불평형 고장해석)

  • Park, Cheol-Won;An, Jun-Yeong;Lee, Jong-Su;Lee, Sang-Seong;Sin, Myeong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.402-404
    • /
    • 2006
  • In this paper, we simulated transient-state under fault in stator windings of synchronous generator. The fault types are line to ground fault, line to line short fault, and three phase short fault. For fault analysis of generator system, the voltage equation of a synchronous machine using the two-axis theory was used. It can be used to analyze important features of faults and to develop enhanced protection methods.

  • PDF

New Fault Location Algorithms by Direct Analysis of Three-Phase Circuit Using Matrix Inverse Lemma for Unbalanced Distribution Power Systems

  • Park, Myeon-Song;Lee, Seung-Jae
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.2
    • /
    • pp.79-84
    • /
    • 2003
  • Unbalanced systems, such as distribution systems, have difficulties in fault locations due to single-phase laterals and loads. This paper proposes new fault locations developed by the direct three-phase circuit analysis algorithms using matrix inverse lemma for the line-to-ground fault case and the line-to-line fault case in unbalanced systems. The fault location for balanced systems has been studied using the current distribution factor, by a conventional symmetrical transformation, but that for unbalanced systems has not been investigated due to their high complexity. The proposed algorithms overcome the limit of the conventional algorithm using the conventional symmetrical transformation, which requires the balanced system and are applicable to any power system but are particularly useful for unbalanced distribution systems. Their effectiveness has been proven through many EMTP simulations.

Engineering Practice for ESS Protection by means of One Point Grounding System (일점접지방식을 이용한 전자교환기 방호의 실제)

  • Kim, Soo-Hyung;Seo, Jung-Uck
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.502-505
    • /
    • 1988
  • This paper is to demonstrate the effectiveness of one point grounding in support of ESS protection. One point grounding provides for the dispatching of excess energy for protection of switching equipment and personnel from lightning discharge hazards and for a natural sink for noise from atmospheric lightning and power transients. In most ESS installations there are a number of different items that must be maintained at a common ground potential for safety, fault protection or noise reduction. The items typically consist of power systems, heating and ventilating systems, distributing frames, repeating equipmets, switching equipments, etc. Grounding system of an ESS Office is most effective when all the ground points are connected to a single, common earth. The one point grounding prvides a common reference potential, keeping all the items of telecommunications facility free from the earth current and voltage hazards.

  • PDF

Evaluation of Efficiency for Grounding System on the Electrified Railways (전기철도 급전시스템의 매설접지 방식 유용성 평가)

  • 창상훈;한문섭;이장무;이형수;김정훈
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.86-92
    • /
    • 2000
  • Recently, the Korea National Railways (KNR) is undertaking a program of electrification of the existing railway routes. In order to implement the ongoing plan, KNR authorized a preliminary engineering study of its electrical systems. This effort included a comprehensive analysis of new grounding networks. The new grounding system runs in parallel with the rails and is connected to all metal structures such as rails, overhead protection wires and substation grounding grids etc., creating an equipotential ground network. This paper presents a study on coupling levels that can disturb signaling and telecommunications in adoption of the new grounding network The simulation for the study is carried out using Matlab software, Several different scenarios are analyzed, including the load condition and a few fault conditions with different fault locations. The induced potentials on the communication cables are computed. The effect of the buried ground wires is also analyzed by comparing the results with and without the presence of the ground wires, The results presented in the paper can be used as a reference for estimating coupling levels in similar rail systems.

  • PDF

A Study on the Transient Characteristics in 765kV Untransposed Transmission Systems (765kV 비연가 송전계통 과도 특성에 관한 고찰)

  • 안용진;강상희
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.397-404
    • /
    • 2004
  • This paper describes a study of transient characteristics in 765kV untransposed transmission lines. As the 765(kV) system can carry bulk power, some severe fault on the system nay cause large system disturbance. The large shunt capacitance and small resistance of 765kv transmission line make various difficulties for its protection. These problems including current difference between sending and receiving terminals on normal power flow, low order harmonic current component in fault current and current transformer saturation due to the long DC time constant of the circuit etc. must be investigated and solved. The analysis of transient characteristics at sending terminal has been carried out for the single phase to ground fault and 3-phase short fault, etc. The load current, charging current in normal condition and line flows, fault current, THD(Total Harmonic Distortion) of harmonics, time constants have been analysed for the 765kV untransposed transmission line systems.

A Study on Energy Characteristics in Transient States of OF Cable Systems (OF 케이블 계통에서 과도상태시 에너지 특성 검토)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won;Lee, Dong-Il;Seo, Je-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.11
    • /
    • pp.468-475
    • /
    • 2006
  • This paper reviews the energy characteristics of oil filled cables in transient state such as grounding fault and lightning surge. Artificial grounding fault test was firstly performed in 2003 for the analysis of arc voltage and breakdown energy according to the fault current. In this paper, energy of OF cable is variously analysed at joint box based on the actual test. Then more various conditions such as installation types, section lengths and CCPU(Cable Covering Protection Unit) connection types are applied for the simulation using EMTP when the single line to ground fault and direct lightning stroke are occurred on actual underground power cable systems and combined power cable systems, respectively. Finally, the energy by the length of crossbonded lead and grounding lead as well as fault lasting time is also calculated using EMTP simulation.

Algorithm of Detecting Ground Fault by Using Insulation Monitoring Device(IMD) in Ungrounded DC System (직류 비접지계통에서 절연저항측정장치(IMD)를 이용한 사고검출 알고리즘)

  • Kim, Ki-Young;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.528-535
    • /
    • 2020
  • Recently, the protection coordination method of DC systems has been presented because renewable energy and distributed resources are being installed and operated in distribution systems. On the other hand, it is difficult to detect ground faults because there is no significant difference compared to a steady-state current in ungrounded IT systems, such as DC load networks and urban railways. Therefore, this paper formulates the detection principle of IMD (Insulation Monitoring Device) to use it as a protection coordination device in a DC system. Based on the signal injection method of IMD, which is analyzed by a wavelet transform, this paper presents an algorithm of detecting ground faults in a DC system in a fast and accurate manner. In addition, this paper modeled an IMD and an ungrounded DC system using the PSCAD/EMTDC S/W and performed numerical analysis of a wavelet transform with the Matlab S/W. The simulation results of a ground fault case in an ungrounded DC system showed that the proposed algorithm and modeling are useful and practical tools for detecting a ground fault in a DC system.

Test field for the application of IEC 60364 in Korea (접지규정 IEC 60364의 국내 적용을 위한 실증시험장 구축)

  • Nam, Kee-Young;Choi, Sang-Bong;Ryoo, Hee-Suk;Lee, Jae-Duck;Jeong, Seong-Hwan;Kim, Dae-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.116-118
    • /
    • 2005
  • IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standards deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries defines the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for themselves. The background of circuit of IEC 60364 is based on the ungrounded system as most of European countries adopt. However, since domestic ground system is multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364 and to evaluate the standard is applicable or not to domestic rule for the protection against ground fault through the related test.

  • PDF

A Study on Fault of Multifunctional Battery Storage System interconnected with Distribution System (배전시스템에 연계된 다기능 전지전력저장시스템의 사고에 관한 연구)

  • Kim, Jae-Chul;Moon, Sun-Ho;Kim, In-Taek;Kim, Eung-Sang;Chu, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1244-1246
    • /
    • 1998
  • This paper present a variety fault problem brought out with the multifunctional Battery Energy Storage System [MBESS] expected to be practical in the short future interconnected to power distribution system. Multifunctional BESS model and interconnection model to power system is simply configured, the problems of protection coordination and operation is studied. A line fault in the power distribution system are discussed such as line to ground and three phase fault in order to show the impact on power utilities, demand-side and BESS-side. In order to simulate a variable transient phenomenon due to 2 the BESS interconnection operation to power distribution system, in this paper, PSCAD/EMTDC simulation tools is used.

  • PDF

Ground fault current variation of 22.9kV CD type superconducting cable system (22.9kV 중성점 다중접지계통에 CD형 초전도케이블을 적용한 경우의 지락전류변화)

  • Lee, Geun-Joon;Lee, Sang-Han;Son, Song-Ho;Hwang, Si-Dol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.46-47
    • /
    • 2006
  • 본 논문은 CD형 초전도 케이블을 22.9kV 다중접지 배전계통에 적용한 경우 불평형 지락 고장이 초전도 케이블에 미치는 영향을 검토하고 이로 인한 중성선 전류의 변화 및 계통보호를 위한 대책을 논한다. 3상 CD형 초전도 케이블을 사용하는 경우 귀로선은 전향선과 전류가 반대이면서 거의 동일한 전류가 흐르므로 회로의 인덕턴스를 크게 줄일 수 있지만 이를 위해 회로를 단락하여 운전하는 경우 지락고장시 영상회로가 별도로 존재하지 않으면 지락전류를 저감시키는 결과를 초래하게 되어 계통보호에 영향을 주게 된다. 본 논문은 EMTDC 프로그램을 활용하여 이 현상을 XLPE 케이블 계통과 비교, 모의하는 한편, 정상적인 보호계전기 동작이 가능토록 하는 대책에 대해 논한다.

  • PDF