• Title/Summary/Keyword: Ground disasters

Search Result 103, Processing Time 0.028 seconds

A Study on the Improvement Method of Forest Fire Caused by Waste Incineration at the Farming Residential Area (농촌 주거지역 쓰레기소각으로 인한 산불화재 개선방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.9-15
    • /
    • 2016
  • Currently the forest area is 6,370,000 hectare (ha) which occupies 63.7% in Korea. The forest has good functions such as production of forest products, conservation of national land, prevention of disasters, etc. However constructing houses near the forest area make bad situation like illegal waste incineration by resident. So research subject is forest fire caused by waste incineration place including facility. And this study was conducted about statistical analysis and research analysis of the 100 waste incineration places including facilities at the country town. Statistical analysis shows that March is 27% which percentage is the highest number of forest fire in 10 years' average. The number of forest fire caused by waste incineration is 45 which is the third highest number in the fire statistic. The distance between waste incineration place including facility and forest area is 30m, 40m and 50m. That 40m (36%) is the most common distance from forest area. The types of waste incineration are ground (62%), the temporary facility made with oil drum can (35%) and other made with steel sheet, concrete, etc. The result of this study is that government and local government must conduct the improvement measure to reduce illegal incineration such as waste pickup area made with rain and wind proof type installed near residence, expenses for waste treatment, enlightenment and training, etc. Also considering their age and income are needed for realistic improvement.

Analysis on Electric Field Based on Three Dimensional Atmospheric Electric Field Apparatus

  • Xing, Hong-yan;He, Gui-xian;Ji, Xin-yuan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1697-1704
    • /
    • 2018
  • As a key component of lighting location system (LLS) for lightning warning, the atmospheric electric field measuring is required to have high accuracy. The Conventional methods of the existent electric field measurement meter can only detect the vertical component of the atmospheric electric field, which cannot acquire the realistic electric field in the thunderstorm. This paper proposed a three dimensional (3D) electric field system for atmospheric electric field measurement, which is capable of three orthogonal directions in X, Y, Z, measuring. By analyzing the relationship between the electric field and the relative permittivity of ground surface, the permittivity is calculated, and an efficiency 3D measurement model is derived. On this basis, a three-dimensional electric field sensor and a permittivity sensor are adopted to detect the spatial electric field. Moreover, the elevation and azimuth of the detected target are calculated, which reveal the location information of the target. Experimental results show that the proposed 3D electric field meter has satisfactory sensitivity to the three components of electric field. Additionally, several observation results in the fair and thunderstorm weather have been presented.

Implementation of Multi-channel Communication System for Drone Swarms Control (군집 드론의 동시제어를 위한 멀티채널 송신 시스템 구현)

  • Lee, Seong-Ho;Han, Kyong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.179-185
    • /
    • 2017
  • Communication technologies hold a significant place in the swarm flight of drones for surveillance, inspection of disasters and calamities, entertainment performances, and drone collaborations. A GCS(ground control station) for the control of drone swarms needs its devoted communication method to control a large number of drones at the same time. General drone controllers control drones by connecting transmitters and drones in 1:1. When such an old communication method is employed to control many drones simultaneously, problems can emerge with the control of many transmitter modules connected to a GCS and frequency interference among them. This study implemented a transmitter controller to control many drones simultaneously with a communication chip of 2.4GHz ISM band and a Cortex M4-based board. It also designed a GCS to control many transmitter controllers via a network. The hierarchical method made it possible to control many more drones. In addition, the problem with frequency interference was resolved by implementing a time- and frequency-sharing method, controlling many drones simultaneously, and adding the frequency hopping feature. If PPM and S.BUS protocol features are added to it, it will be compatible with more diverse transmitters and drones.

Disasters in eastern Japan by the 2011 off the Pacific coast of Tohoku earthquake and ensuing tsunami

  • Shiiba, Michiharu;Yoshitani, Junichi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.7-7
    • /
    • 2011
  • On March 11 in 2011, off the Pacific coast of Tohokua huge earthquake of Magnitude 9.0 occurred. This presentation reports the earthquake, the ensuing tsunami and the devastating damages caused by them. The epicenter was approximately 72 km east of the Oshika Peninsula of Tohoku, with the hypo-center at an underwater depth of approximately 32 km. Owing to this earthquake, strong quakes were observed in eastern Japan with the levels 6 and 7 on the Japanese scale. The earthquake triggered extremely destructive tsunami wave, which attacked the very wide range of eastern Japan coast. The earthquake and ensuing tsunami caused severe damage to levees and embankment along the coasts and rivers. Those water-related damages are reported in this presentation. The Fukushima No. 1 Nuclear Power Plant was also damaged by the earthquake and ensuing tsunami. From the crippled nuclear power plant, appreciable quantities of radioactive material were emitted to the surrounding environment. Those substances which emitted to air may fall on the ground together with raindrops and runoff to rivers. Elucidation of those processes is the task which our hydrological society should undertake.

  • PDF

January 24, 2020 Sivrice Earthquake and the response of the masonry Haci Yusuf Tas (New) mosque

  • Firat, Fatih K.;Ural, Ali;Kara, Mehmet E.
    • Earthquakes and Structures
    • /
    • v.22 no.4
    • /
    • pp.331-343
    • /
    • 2022
  • Masonry structures are the most common structural systems that have been used almost all over the world from the earliest ages of history to the present day. These structural systems are often unfavorably affected by natural disasters such as earthquakes. The main reason for this is that they are built without sufficient engineering knowledge. On January 24, 2020, a severe earthquake occurred near the Sivrice District of Elazığ in eastern Turkey. According to the Turkish Directorate of Disaster and Emergency Management (AFAD), the magnitude of the earthquake was 6.8 and the focal depth 8 km. This earthquake caused damage and destruction to the masonry structures used extensively in the region. The Hacı Yusuf Taş (new) mosque in the Malatya city center, located about 64 km from the epicenter of the earthquake, was among the buildings affected by the earthquake. The mosque has smooth-cut stone walls and domes made of brick units. The main dome of the structure was severely damaged during the earthquake. In this study, information about the earthquake is first provided, and the damage to the mosque is then interpreted via photographs. In addition, two separate finite element models were produced, where the current state of mosque and solution suggestions are presented, and response spectrum analyses were carried out. According to these analyses and field observations, a buttress system to the main walls of the structure should be constructed in the direction which has little lateral rigidity.

Unsaturated Soil Properties of Compacted Soil at Sub-Zero Temperature (영하온도에서 다짐된 지반의 불포화 특성)

  • Lee, Jeonghyeop;Hwang, Bumsik;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.3
    • /
    • pp.5-13
    • /
    • 2018
  • Recently, construction disasters in thawing season are increasing due to the ground collapse and it is related to the improper compaction during winter season. Compaction at sub-zero temperature reduces the compaction effect and the research of mechanical properties of thawed soil after winter compaction can be used as useful data to understand the behavior of the ground in the thawing season. On the other hand, the research interest in the unsaturated soil mechanics has been increasing in the field of the geotechnical engineering. Therefore, it is expected that the research of unsaturated characteristics under the compaction of sub-zero temperature and freezing & thawing condition provides information to the researchers in the related fields. Therefore, in this research, unsaturated soil-water characteristics test and unsaturated uniaxial compression test were conducted on the specimens compacted at sub-zero temperature and continuous freezing & thawing condition to investigate change of unsaturated characteristics and matric suction. Based on the test results, the change of matric suction and the decrease of strength and stiffness were observed with the freezing & thawing conditions. Especially in case of the weathered soil, the strength and matric suction were significantly reduced with lower temperature and more repetition of freezing & thawing cycles. This result implies that compaction of sub-zero temperature and freezing & thawing cycles will have a considerable influence on the stability of the ground.

Evaluation of satellite-based soil moisture retrieval over the korean peninsula : using AMSR2 LPRM algorithm and ground measurement data (위성기반 토양수분 자료의 한반도 지역 적용성 평가: AMSR2 LPRM 알고리즘과 지점관측 자료를 이용하여)

  • Kim, Seongkyun;Kim, Hyunglok;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.5
    • /
    • pp.423-429
    • /
    • 2016
  • This study aims at assessing the quality of the Advanced Microwave Scanning Radiometer 2 (AMSR2) soil moisture products onboard GCOM-W1 satellite based on Land Parameter Retrieval Model (LPRM) soil moisture retrieval algorithm with field measurements in South Korea from March to September, 2014. Results of mean bias and root mean square error between AMSR2 LPRM soil moisture products (X-band) and ground measurements showed reasonable value of 0.03 and 0.16. Also, the maximum of the Pearson correlation coefficients was 0.67, which showed good agreement in terms of temporal variability with ground measurements. By comparing AMSR2 soil moisture with in-situ measurement according to the overpass time and band frequency, X-band products on the ascending time outperformed than those of C1-band and C2-band. Furthermore, this study offers an insight into the applicability of the AMSR2 soil moisture products for monitoring various natural disasters at a large scale such as drought and flood.

Utilization of Drone LiDAR for Field Investigation of Facility Collapse Accident (붕괴사고 현장조사를 위한 드론 LiDAR 활용)

  • Yonghan Jung ;Eontaek Lim ;Jaewook Suk;Seul Koo;Seongsam Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_2
    • /
    • pp.849-858
    • /
    • 2023
  • Investigating disaster sites such as earthquakes and landslides involves significant risks due to potential secondary disasters like facility collapse. In situations where direct access is challenging, there is a need to develop methods for safely acquiring high-precision 3D disaster information using light detection and ranging (LiDAR) equipped drone survey systems. In this study, the feasibility of using drone LiDAR in disaster scenarios was examined, focusing on the collapse accident at Jeongja Bridge in Bundang-gu, Seongnam City, in April 2023. High-density point clouds for the accident bridge were collected, and the bridge's 3D terrain information was reconstructed and compared to the measurement performance of 10 ground control points. The results showed horizontal and vertical root mean square error values of 0.032 m and 0.055 m, respectively. Additionally, when compared to a point cloud generated using ground LiDAR for the same target area, a vertical difference of approximately 0.08 m was observed, but overall shapes showed minimal discrepancies. Moreover, in terms of overall data acquisition and processing time, drone LiDAR was found to be more efficient than ground LiDAR. Therefore, the use of drone LiDAR in disaster sites with significant risks allows for safe and rapid onsite investigations.

Development and Verification of A Module for Positioning Buried Persons in Collapsed Area (붕괴지역의 매몰자 위치측위를 위한 모듈 개발 및 검증)

  • Moon, Hyoun-Seok;Lee, Woo-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.427-436
    • /
    • 2016
  • Due to disasters such as earthquakes and landslides in urban areas, persons have been buried inside collapsed buildings and structures. Rescuers have mainly utilized detection equipment by applying sound, video and electric waves, but these are expensive and due to the directional approaches onto the collapsed site, secondary collapse risk can arise. In addition, due to poor utilization of such equipment, new human detection technology with quick and high reliability has not been utilized. To address these issues, this study develops a wireless signal-based human detection module that can be loaded into an Unmanned Aerial Vehicle (UAV). The human detection module searches for the 3D location for buried persons by collecting Wi-Fi signal and barometer sensors data transmitted from the mobile phones. This module can gain diverse information from mobile phones for buried persons in real time. We present a development framework of the module that provides 3D location data with more reliable information by delivering the collected data into a local computer in the ground. This study verified the application feasibility of the developed module in a real collapsed area. Therefore, it is expected that these results can be used as a core technology for the quick detection of buried persons' location and for relieving them after disasters that induce building collapses.

Application of Total Station for Structure and Terrain Displacement Monitoring (구조물 및 지형변위 모니터링을 위한 토털스테이션의 활용)

  • Park, Joon-Kyu;Um, Dae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.582-587
    • /
    • 2020
  • Recently, disasters caused by extreme weather and the damage caused by them are increasing worldwide. The interest in disasters, such as earthquakes, typhoons, and ground subsidence, is increasing in Korea. Korea has enacted a special law based on disaster management, and has built monitoring systems for individual facility units by building precision sensors and related systems to measure the displacement status of long bridges and high-rise composite buildings. On the other hand, the application of a real-time monitoring system is insufficient for slopes, open-pit mines, small and medium structures due to weather, measurement methods, cost, and constant monitoring difficulties. In this study, the displacement monitoring method using the total station was studied and the applicability was suggested through the experiment. Through the research, the concept and operation flow of a monitoring system that can measure the displacement of the terrain or the structure using the total station was presented. The monitoring system allows the user to select the location and operation method of the equipment so that the equipment can be installed according to the site situation, and set the number of observations, the period, and the observation range of the object. Using the experiment on the monitoring system, the station was monitored with precision within 5mm, and it was suggested that the displacement of the object can be monitored using the total station. Further research will be needed to assess the applicability of monitoring to real slopes and structures.