가변주파수 인버터를 이용한 접지임피던스의 새로운 측정기법 (A Novel Method for Measuring the Ground Impedance using Variable Frequency Inverter)

  • 이복희;엄주홍
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.253-257
    • /
    • 2004
  • In order to analyze the frequency dependance of ground impedance in grounding grids for lightning and surge protection, a novel method for measuring the ground impedance as a function of frequency were experimentally investigated. The experiments were carried out in rectangular grounding grids with $6{\times}8$ conductors of 22 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the variable frequency inverter whose frequency is linearly controlled for the established period in the range of 5∼500 KHz. The amplitude and phase of ground impedance were calculated from the waveforms of the test current and ground potential rise measured by the band-pass filter tuned in a specific frequency. The frequency dependence of ground impedance was mainly caused by the inductive current flowing through grounding conductors over the frequency of 100 KHz. The proposed measurement method of ground impedance would be applicable to evaluate the transient response characteristics in lightning protection grounding systems.

다양한 전류원에 대한 접지시스템의 위험전압 측정과 분석 (Measurement and Analysis of Risk Voltages by Various Current Sources in Grounding System)

  • 길경석;문병두;김황국;박대원;길형준
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.113-118
    • /
    • 2009
  • Grounding systems set the reference voltage level of electric circuits and suppress the Ground Potential Rise (GPR) by flowing fault currents to the ground safely. There are several parameters which evaluate the performance of grounding systems as ground resistance, touch voltage and step voltage. The touch and step voltages, which is called "risk voltage", are especially important to ensure the safety of human body. This paper dealt with the influence of current sources with the different frequency components on the touch and the step voltages. Three types of current sources as commercial frequency, square wave, and surge with the fast risetime of $50\;ns{\sim}500\;ns$ were used to analyze the risk voltages in a grounding system. The risk voltages showed remarkable difference in the same current amplitude depending on the current sources, and increased linearly with the current amplitude in the same current source. From the experimental results, it was confirmed that the risk voltages can be evaluated by a small current application in large-scale grounding systems and the possible largest risk voltage can be calculated by a surge current with the risetime of 200 ns or a current source with the same frequency component as the surge current.

직류 전기철도에서의 레일전위 및 누설전류 해석을 위한 시뮬레이션 모델링 (A Simulation Modeling for Rail Potential and Leakage Current Analysis in DC Traction System)

  • 윤임중;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.196-201
    • /
    • 2008
  • In DC traction systems, a part of feedback current returning through rails becomes leakage current, illumination on a metal laid underground results from the leakage current to ground. To prevent the leakage current on rails, feedback rails almost have insulated with the ground. Insulation between rails and the ground causes that the earth method changes a isolated method in DC traction systems. the rail potential rise results in the isolated method. the rail potential rise causes an electric shock when a person touches the ground and rolling stock. To decrease the rail potential rise and leakage current, there are methods for reducing the feedback resistance and current of rails, increasing the leakage resistance, decreasing the distance between substations. But it are necessary to forecast and analyze the rail potential and amplitude of leakage current. In this paper, we modeled DC traction systems and feedback circuit to simulate the rail potential and amplitude of leakage current using PSCAD/EMTDC that is power analysis program, forecasted the rail potential and amplitude of leakage current about changing various parameters in the electric circuit. By using the simulation model, we easily will forecast the rail potential and amplitude of leakage current in case of a level of basic design and maintenance in electric railway systems, valuably use basic data in case of system selection.

  • PDF

대형 봉상 접지전극의 길이에 따른 뇌 임펄스 특성 (Lightning impulse characteristics of large-scale ground rods with different length)

  • 이복희;장근철;엄주홍;김병근;정동철;길형준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.233-235
    • /
    • 2003
  • To obtain a low ground resistance in high resistivity soil or in insufficient place such as downtown, long vertical ground rods are often used. However, if the lightning current or fault current with high frequency flows into the grounding system, the ground impedance is significantly increased. This paper presents how the impulse current works on the long vertical ground rods with a different length. As a result, it can be estimated what the waveform is composed of and how the GPR is affected by the rate of current change.

  • PDF

22.9kV다중접지선로 지락고장점 대지유입전류 및 중성선분류 해석 (An analysis of The ground fault current Distribution of 22.9kV-Y Lines)

  • 임용훈;현덕화;최종기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.473-475
    • /
    • 2004
  • During ground faults in power system, large current and raised potential appear at nearby places. This paper presents an analytical procedure of the ground fault current for the towers of a transmission line(154kV) and distribution line(22.9kV) of an arbitrary number of spans during ground faults. In order to economically and securely protect against undesired consequences, it is necessary to evaluate as precisely as possible the value and distribution of the ground fault current.

  • PDF

임펄스전류에 의한 매설지선의 과도임피던스특성에 대한 모의해석 (Simulated Analysis for the Transient Impedance Behaviors of Counterpoises Subjected to the Impulsive Currents)

  • 조정현;이복희
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1861-1868
    • /
    • 2009
  • A ground electrode subjected to lightning surge current shows the transient impedance behaviors. The ground electrode for protection against lightning should be evaluated in view of the transient grounding impedance and conventional grounding impedance, not ground resistance. The transient impedance characteristics of ground electrodes are influenced by the shape of ground electrode and the soil characteristics, as well as the waveform of lightning surge current. In order to propose a simulation method of analyzing the transient impedance characteristics of the grounding system in practical use, this paper suggests a theoretical analysis method of distributed parameter circuit model to simulate the transient impedance characteristics of counterpoise subjected to lightning surge current. EMTP and Matlab programs were employed to compute the transient grounding impedances of three counterpoises with different lengths. As a consequence, the simulated results using the proposed distributed parameter circuit model are in good agreement with the measured results.

1선 지락 사고 시 3 권선 변압기에 적용된 초전도 한류기의 동작 특성 분석 (Analysis of Transient Characteristics of a SFCL Applied Into Third-winding Transformer in a Single Line-to-ground Fault)

  • 최혜원;최효상;정병익
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.1033-1037
    • /
    • 2013
  • Coercion transformer is commonly used in the electrical grid which in three phase of distribution system. The accident of the electrical grid is divided into a single, a double, a third line-to-ground faults and a double, a third line-to-line faults. A single line-to-ground fault accounts for nearly 75[%] among them. In this research, when a Superconducting Fault Current Limiters (SFCL) was applied to the three phase power system, operation in a single line-to-ground fault and limiting characteristics of fault current according to turns ratio of third winding were analyzed. When a single line-to-ground fault happened, secondary winding's circuit was open. Then third winding's circuit with a SFCL was closed. So fault current was limited by diverted circuit. At this time, we could find out that size of the limited fault current could be changed according to third winding rate. We confirmed that limiting operation of the fault current was carried out within one-period. These results will be utilized in adjusting the size of the SFCL.

광대역 접지임피던스 측정기의 설계 및 제작 (Design and Fabrication of a Wideband Ground Impedance Meter)

  • 길경석;박대원;장운용;한주섭;길형준
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.793-797
    • /
    • 2010
  • The basic performance of the ground system is evaluated as the ground resistance by applying low frequency current below 1 kHz. However, characteristics of the ground system should be analyzed by high frequency current up to 1 MHz since transient currents having a few hundred kHz component flow during a line-to-ground fault and/or a lightning strike. This paper deals with the design and fabrication of a wideband ground impedance meter (WGIM) which measures the impedance of ground systems in ranges from 65 Hz to 1.28 MHz. Also, a noise elimination algorithm using a digital bandpass filter is proposed. The maximum error of the WGIM is 4.91% in the measurement frequency range.

22.9kV 중성점 다중접지계통에 CD형 초전도케이블을 적용한 경우의 지락전류변화 (Ground Fault Current Variation of 22.9kV Multi Neutral Grounded Distribution System with CD Type Superconducting Cable)

  • 이종배;황시돌;손송호;이근준
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.993-999
    • /
    • 2007
  • This paper discusses the effects of CD type superconducting cable operation in 22.9kV multi neutral grounded distribution system during L-G fault and counterplans to power system protection. In case of using the 3-phase CD-type superconducting cable, the inductance of superconducting cable system would be decreased due to the current of shield part of superconducting cable, which is opposite direction and nearly equal value with respect to main superconductor. However, when the shield circuit system is operated in shorted state, shield current decreases faulted ground current and give effects to power system protection scheme. This study examines the phenomena of single line to ground fault case in above mentioned system using the EMTDC program and discusses the right operation method of superconducting shield.

전력계통의 중성선에 적용된 초전도한류기의 대칭고장전류 저감방안 분석 (Analysis on Reduction Method of Symmetrical Fault Current in a Power System with a SFCL applied into Neutral Line)

  • 임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제23권2호
    • /
    • pp.148-152
    • /
    • 2010
  • The superconducting fault current limiter (SFCL) applied into the neural line of a power system, which can limit the unsymmetrical fault current from the single-line ground fault or the double-line ground fault, was reported to be the effective application location of the SFCL in a power system. However, the limiting operation for the symmetrical fault current like the triple line-ground fault is not effective because of properties of the balanced three-phase system. In this paper, the limiting method of the symmetrical fault current in a power system with a SFCL applied into neutral line was suggested. Through the short-circuit experiments of the three-phase fault types for the suggested method, the fault current limiting and recovery characteristics of the SFCL in the neutral line were analyzed and the effectiveness of the suggested method was described.