• Title/Summary/Keyword: Ground Shock

Search Result 190, Processing Time 0.028 seconds

Design Procedures of SCRamjet Engine Intake and Numerical Analysis (스크램제트 엔진 흡입구의 설계 및 3차원 성능해석)

  • Kang, Sang-Hun;Shin, Hun-Bum;Yang, Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.339-343
    • /
    • 2006
  • Model SCRamjet Engine intake is designed for Ground test. The designed Intake provides hot and slow flow with the combustor. Flow separation is controlled by the shock wave segregation based on the Korekegi criteria. With Kantrowitz limit analysis, side wall cut out region is also set for the self start.

  • PDF

Considering design parameters in terms of rail potential and leakage current in DC feeding system (직류급전시스템의 레일전위와 누설전류 관점에서의 설계 파라미터 연구)

  • Han, Moon-Seob;Jung, Ho-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.236-241
    • /
    • 2007
  • DC feeding system is mainly floating but the rail potential and the leakage current are created because of long parallelism between rails and ground. Rail potential causes electric shock to human and leakage current causes electrolytic corrosion to nearby the buried metals. Therefore the design technologies to reduce, protect and monitor these effects are important recent DC feeding system. Normally during designing DC feeding system in terms of rail potential and leakage current, there are about 10 parameters. Four design parameters among those is analysed based on propagation theory that is utilized in order to simulate grounding system.

  • PDF

Comparisons of Isolation Performances for the SMA Mesh Washer Isolator with the Variation of Pre-compressed Displacement (초기압축변위에 따른 형상기억합금 메쉬 와셔 절연계의 절연 성능 비교)

  • Youn, Se-Hyun;Jeong, Ho-Kyeong;Han, Jae-Hung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.2
    • /
    • pp.162-168
    • /
    • 2011
  • Launch vehicles and satellites experience severe vibration and pyroshock during the flight phase. These severe dynamic loading could result in the malfunction of electric devices which equipped in the launch vehicle and satellite. In this paper, mesh washer isolators are applied to attenuate these severe shock and vibration and isolation performances are enhanced by applying pseudoelasitic SMA wire material. Through random vibration and ground pyroshock tests, outstanding isolation performances are studied. Especially, comparison of isolation performances due to the change of pre-compressive displacement of mesh washer itself are suggested and applicablity to the adaptive vibration control are confirmed.

Design of Passive Vibration Attenuation System for a Vehicle HDD (차량용 HDD 의 수동형 진동저감 시스템 설계)

  • Kim, Jin-Nam;Kim, Young-Chu;Kwon, Won-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.117-122
    • /
    • 2010
  • The shock performance of hard disk drives has been a serious issue for Car PC. Since the vibration and disturbances from a car gives an adverse effect on a HDD of Car PC, it is necessary to protect a HDD from them. In this study, passive vibration attenuation system for a vehicle HDD was developed. Acceleration from the ground through the tire and suspension system was measured to figure out the frequency translated to Car PC. Critical frequency to Car PC was determined by exciting it with a shaker and measuring a data transmitting speed from HDD. A newly designed vibration attenuation system was fabricated to protect HDD from the acceleration. It was shown that the developed system had an excellent vibration attenuation ability.

A Study on the Indwelled Accident Factors in Small & Medium-Sized Construction Sites Utilizing Safety Consulting Data (건설재해예방기술지도 결과자료 분석을 통한 중$\cdot$소 건설 현장의 잠재사고 유발 요인 개선 방안 연구)

  • Hong Sung Man;Yoon Young Goo;Kweon Dae Chul;Park Peom
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.3 s.67
    • /
    • pp.84-88
    • /
    • 2004
  • Accident of small and medium-sized construction sites happens much than large-sized construction sites. The safety consulting for accident prevention of construction sites has been launched in 1995. This research probed latency accident of small and medium-sized construction sites. By method, we used that result data of safety consulting for accident prevention of small and medium-sized construction sites. As a result a fall was examined by the most latency accident factor. In this study, a fall and electric shock, descent, fall down in ground, a fire was examined weighty accident factor of small and medium-sized construction sites.

Natural Frequencies of Nonsymmetrically Tapered Beams (비대칭 변단면 보의 고유진동수)

  • 백봉인;안성기;김순철;이수곤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.267-274
    • /
    • 1999
  • An understanding of the natural frequencies of a beam is virtually a prerequisite to the understanding of its response in forced vibration due to shock, ground acceleration or moving loads. Contrary to the frequencies of the prismatic bars with arbitrary boundary conditions, those of a tapered bar are hard to determine when one employs convevtional neutral equilibrium or energy method. In this paper, finite element method is adopted to determine the fundamental frequencies of the non-symmetrically tapered bars. The bars assume the shapes of straight lines along the axis. The parameters considered in this study are sectional parameter, m,n and taper parameter, $\alpha$ For the structural engineer's convenience, the results by finite element method are expressed by simple algebraic equations, by which first mode frequencies are easily estimated. And they agree fairy well with those by F.E.M in most cases.

  • PDF

Analysis on Voltage Rise of Rail in High speed Railway System (고속철도 시스템의 레일 전위 상승 해석)

  • Myung, Sung-Ho;Lee, Jae-Bok;Lee, Jong-Woo;Lee, Jang-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1365-1367
    • /
    • 2000
  • In electric railway system, potential of rail has been risen, for return-current flows through rail. The magnitude of rising voltage is different to railway feed system, ground admittance of rail and the load current. If rising voltage of rail is large, electric shock can be occurred to passengers and maintenance-worker. In this paper, we estimate the rising voltage of rail in high speed railway system and check the safety to human beings.

  • PDF

GPS Translator Design and Manufacturing for High Dynamic Vehicle (고기동 항체의 위치추적용 GPS 중계기 설계/제작)

  • 강설묵;이상정
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.39-48
    • /
    • 2003
  • A GPS translator system is used to get the precise and reliable trajectory data for the high dynamic test vehicles, such as missiles or artillery shells. The missile system with high dynamics, vibration and shock needs to determine its position and velocity in particular. The proposed GPS translator on the test vehicle receives GPS signals, amplifies, down-converts, digitally samples, BPSK modulates, up-converts them to S-band, and then retransmits them to the ground translator processing station. It has doppler variation and signal noise, so design method for resolving them is proposed. The performance of the translator is proved by environmental test and real flight test.

Measurement of Vibration Signals of a Gun Barrel Type Structure using Mechanical Filter (기계적 필터를 이용한 포신형상 구조물의 진동신호 측정)

  • Ryu, Bong-Jo;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.440-443
    • /
    • 2010
  • This paper deals with the method of vibration measurement of a gun barrel structure using mechanical filter. When a bullet with high speed is moving within a gun barrel type structure with low bending vibration frequencies, it is difficult to measure the bending vibration signals of the structure. For example, noncontact type sensors such as displacement or velocity sensor are not appropriate for the measurement of vibrational signals because of the movement effect of the equipment frame through the moving structures or effect of the ground vibration. One of contact type sensors such as accelerometer is profitable for measurement of vibrational signals because of its wide measurement ranges. In the case of a gun barrel structure including high vibrational signals like shock waves, however, it is necessary to propose vibration measurement method filtering high frequencies. The purpose of the paper is to propose the proper vibrational measurement technique filtering high frequencies of a gun barrel type structure.

Masonry building behaviors during the February 6-12, 2017 Ayvacik-Çanakkale Earthquakes

  • Ural, Ali
    • Earthquakes and Structures
    • /
    • v.17 no.4
    • /
    • pp.355-363
    • /
    • 2019
  • Masonry structures in the rural areas of Turkey often damaged due to moderate and big earthquakes. After every earthquake many scientists made field investigations on the earthquake performance of these structures and gave many useful information on construction techniques. However, the newly constructed masonry buildings are still not suitable for the suggested techniques, and they are still in danger against future earthquakes. Five moderate earthquakes of moment magnitude Mw 5.3, 5.3, 5.2, 5.0, and 5.3 struck the Ayvacik-Çanakkale District of Turkey between 6 and 12 February, 2017. More than a thousand of aftershocks were occurred and most of the masonry buildings in the villages nearby main shock epicenter were affected. The author went to the earthquake field and investigated the earthquake performances of masonry structures. This paper presents the recorded acceleration data, acceleration response spectra, and the seismological aspects of these earthquakes. Besides, case studies of damaged stone masonry buildings, and failure mechanisms are discussed with illustrated photos which were taken during the field investigations. It is concluded that the damaged masonry buildings were not designed and constructed properly in accordance with the Turkish building codes or similar specifications.