• Title/Summary/Keyword: Ground Resonance

Search Result 207, Processing Time 0.03 seconds

Investigation of the Reaction Coordinate for Dissociation in $Cr(CO)_6$ Using Resonance Raman Spectroscopy

  • 유수창;고석범;J. B. Hopkins
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.11
    • /
    • pp.1043-1045
    • /
    • 1995
  • The overtone of the ν2 vibrational mode in Cr(CO)6 are observed for the first time in cyclohexane and methanol at both the 266 and 213 nm excitations. The appearance of the overtones due to the displacement of the electronic excited state with respect to the ground state along the ν2 vibrational mode is interpreted in terms of wavepacket concept and molecular orbital (MO) theory. Our Raman results suggest a new interpretation for the excited state potential.

A Study on Characteristics of Coupled Line Employing Periodical Ground Structure on GaAs MMIC (GaAs MMIC상에서 주기적 접지구조를 가지는 결합선로의 절연특성에 관한 연구)

  • Kim, Se-Ho;Kang, Suk-Youb;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.159-165
    • /
    • 2009
  • In this study, using a periodical ground structure(PGS) on GaAs monolithic microwave integrated circuit(MMIC), transmission line with a high isolation characteristic was developed for application to compact signal/bias lines of highly integrated MMIC. And the origin of the high isolation characteristic was theoretically investigated. The high isolation characteristic was originated from a resonance between adjacent microstrip lines employing PGS. With only a spacing of $20{\mu}m$, the coupled microstrip line employing PGS showed an isolation value of -47 dB at 60 GHz. The frequency range for high isolation was easily controlled by changing the PGS structure. Above results indicate that microstrip lines employing PGS are very useful for application to compact signal/bias lines of highly integrated MMIC requiring a high isolation characteristics between lines. In addition, equivalent circuit employing closed-form equation for the coupled line with PGS was also extracted.

High Efficient Phase Shifters Using Defected Ground Structures (결함 접지 구조를 이용한 고성능 위상 천이기)

  • Han Sang-Min;Kim Chul-Soo;Ahn Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.1 s.104
    • /
    • pp.1-7
    • /
    • 2006
  • New phase shifters with higher phase shift values are presented using defected ground structures(DGSs). The varactor diodes are mounted on DGSs of termination loads to control the large phase variation of the DGS at resonance. Two types of phase shifters are implemented with a branch-line and a coupled line hybrid. The experimental results of the proposed phase shifters show $135\%$ and $221\%$ increases in maximum phase shills, respectively, compared with those of conventional ones.

A Design of The Meander Line Inductor With Good Sensitivity Using Aperture Ground plate and Multi-layer PCB (개구 접지 면과 적층 PCB를 이용한 우수한 민감도를 갖는 미앤더 선로 인덕터 설계)

  • Kim, Yu-Seon;Nam, Hun;Jung, Jin-Woo;Lim, Yeong-Seog
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.12 s.354
    • /
    • pp.75-82
    • /
    • 2006
  • In this paper, we design the meander line inductors with high sensitivity and high quality factor(Q) using high characteristic impedance of aperture ground plate. Sensitivity as a frequency is new defined by variation of effective inductance per analysis frequency range instead of self resonance frequency (SRF). An equivalent lumped circuit is derived to explain the characteristic of high frequency inductor. The 4 nH meander line inductor with aperture ground plate has 0.45 nH/GHz of good sensitivity and 86 of Q at 0.7 GHz.

UV Resonance Raman Studies of Cis-Peptide, Diketopiperazine (자외선 공명 라만분광법을 이용한 시스-펩티드, 디케토피페라진 연구)

  • Song, Sunho
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 1993
  • We have examined Raman spectra of cis-peptide model complex, diketopiperazine in water and $D_2O$ with 320 nm through 218 nm excitation. Our study examines assignment of the resonance enhanced amide vibrations and characterizes their enhancement mechanism. Three resonance enhaned cis-peptide marker bands were observed in aqueous solution at 1676, 1533 and $806cm^{-1}$, which were assigned to the cis-amide I, II and S band, respectively. The $1533cm^{-1}$ amide II band, which is almost pure C-N stretching, was most dominant in water and shifted to $1520cm^{-1}$ upon N-deuteration. This band will be probably a potential probe band for cis-peptide moieties in proteins. The excitation profile data and an Albrecht A-term fit indicated that the cis-peptide vibrations derive their intensities from the 188 nm cis-peptide ${\pi}-{\pi}^*$ electronic transition. We Propose that the geometry of cis-peptide ${\pi}^*$ excited state is C-N bond displacement relative to that of electronic ground state.

  • PDF

Insertion Loss Characteristics of a Parallel Two-Wire Transmission Line with Equal Line Length Due to a Rectangular Aperture Sizes in Dual Ground Planes (두 개의 접지 평판 사각형 개구의 변화에 따른 평행 2선 전송 선로의 삽입 손실 특성)

  • Jung, Sung-Woo;Lim, Sung-Min;Jin, Jung-Hi;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.675-682
    • /
    • 2011
  • This paper presents two ground plane effects due to the size of two rectangular apertures for two-wire transmission line with equal line length crossing the changeable rectangular apertures in infinite ground planes. The CST MWS is used to determine the characteristics of the insertion loss of the transmission line from the load section in accordance with the ground plane aperture size. The results show that the insertion gain and the insertion loss are periodically observed for the multiple frequency of the half wavelength resonance by the wire length when the transmission line is nearby to horizontal side or vertical side of the aperture. The measurements of the insertion loss are performed to verify the theoretical analysis.

Analysis of the Ground Bounce in Power Planes of PCB Using the Haar-Wavelet MRTD (Haar 웨이블릿 기반 MRTD를 이용한 PCB 전원 공급면에서의 Ground Bounce 해석)

  • 천정남;이종환;김형동
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.1065-1073
    • /
    • 1999
  • This paper analyzed the ground bounce caused by the power plane resonance in the multilayered printed circuit board(PCB) using the Haar-wavelet-based Multiresolution Time-Domain (MRTD). In conventional Finite-Difference Time-Domain(FDTD), the highly fine vertical cell is needed to represent the distance between $V_{cc}$ plane and ground plane since the two planes are very close. Therefore the time step $\Deltat$ must be very small to satisfy the stability condition. As a result, a large number of iterations are needed to obtain the response in wanted time. For this problem, this paper showed that the computation time can be reduced by application of the MRTD method. The results obtained by the MRTD agree very well with those by FDTD method and analytic solutions. In conclusion, this paper proved the efficiency and accuracy of MRTD method for analyzing the EMI/EMC problems in PCB.

  • PDF

Dynamic Amplification Characteristics of Major Domestic Seismic Observation Sites using Ground Motions from Domestic Macro Earthquakes (국내 중규모지진의 자료를 이용한 주요 관측소 지반의 동적 증폭특성에 관한 연구)

  • Kim, Jun Kyoung
    • The Journal of Engineering Geology
    • /
    • v.22 no.4
    • /
    • pp.399-408
    • /
    • 2012
  • To estimate seismic source and soil-structure interaction more reliably, site amplification characteristics should be considered. Among the various estimation methods, we used Nakamura's method (1989) to estimate site amplification. This method was originally applied to background noise; however, it has recently been successfully applied to S-wave and Coda-wave energy, and is applied to S-waves in the present study. We used more than 180 observed ground motions from 23 macro-earthquakes and then analyzed site amplification characteristics at eight seismic stations. Each station showed characteristics of site amplification properties in the low-, high- and resonance-frequency ranges. Comparison of the present results with those of other studies provide successful information regarding the dynamic amplification of domestic site characteristics and site classification.

Magnetic Resonant Wireless Power Transfer Using Reconfigurable Slit Ground Resonator for Laptop Computer (재구성 슬릿 그라운드 공진기를 이용한 노트북용 자기공진형 무선전력전송)

  • Kang, Seok Hyon;Jung, Chang Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • In this paper, slit ground resonator with slit and capacitor is proposed for practical use of magnetic resonant wireless power transfer(MR-WPT). And this paper presents the performance comparison of conventional loop resonator as Rx resonator to slit ground resonator. The proposed silt ground resonator with 31 cm width, 20.5 cm length, $35{\mu}m$ thickness is designed the crossing slit 1 cm width with only opened edge. And an external capacitors were connected at the opened edge of slit ground resonator for resonating at 6.78 MHz. The transfer efficiencies of MR-WPT were measured at open and short mode, and then the highest transfer efficiencies of MR-WPT according to the Rx resonators were plotted. In result, the transfer efficiency of MR-WPT with loop resonator was the highest. However, when the ground was inserted in receiver part at the bottom of laptop model, the transfer efficiency was closed 0 %. The transfer efficiency recovered the transfer efficiency of 67 % using slit ground resonator. The magnetic field was penetrated through the slit and proposed slit ground resonator works as resonator in MR-WPT.

A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable (무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구)

  • Kim, Yeong-Han;Choi, Jong-Hyuck;Yoon, Ki-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF