• Title/Summary/Keyword: Ground Injection

Search Result 288, Processing Time 0.025 seconds

Clogging theory-based real time grouting management system applicable in soil conditions

  • Kwon, Young-Sam;Kim, Jinchun;Lee, In-Mo
    • Geomechanics and Engineering
    • /
    • v.16 no.2
    • /
    • pp.159-168
    • /
    • 2018
  • In this study, a real-time grouting management system based on the clogging theory was established to manage injection procedure in real time. This system is capable of estimating hydraulic permeability with the passage of time as the grout permeates through the ground, and therefore, capable of estimating real time injection distance and flow rate. By adopting the Controlled Injection Pressure (CoIP) model, it was feasible to predict the grout permeation status with the elapse of time by consecutively updating the hydraulic gradient and flow rate estimated from a clogging-induced alteration of pore volume. Moreover, a method to estimate the volume of the fractured gap according to the reduction in injection pressure was proposed. The validity of the proposed system was successfully established by comparing the estimated values with the measured field data.

Determining of Ground Condition Criteria for Dam Reinforced RIM Grouting (댐체 강화 RIM부 그라우팅을 위한 지반상태 기준 결정)

  • Han, Kiseung;Lee, Donghyuk;Park, Duhee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.2
    • /
    • pp.181-186
    • /
    • 2022
  • Dam slope RIM is a highly important contact interface where the main body and the base surface are connected. In general, when the grouting for the slope of the dam structure is designed, it is planned using limited data (drilling, geological map, etc.). This makes it very difficult to accurately consider the original ground characteristics of the slope RIM grouting target, In addition, when the grouting volume planned during the design is drilled and injected into the original ground where the waterstop is secured, there is a possibility that the original ground with the waterstop is disturbed and the effect of the waterstop is rather diminished. In order to overcome such problems, it is more suitable to first consider geological conditions and determine whether to perform optimal grouting on the original ground through on-site repair tests before performing RIM grouting. In this paper, to determine the grouting of the RIM unit, a pilot hole water pressure test was performed on the rock of the slope in the target section. The analysis shows grouting volume of 1 Lugeon or less, and the cement injection amount also shows the injection result of 1 kg/m or less. In this case, performing grouting is rather counterproductive. This result can be evaluated through a rock of which some degree of order of mass is secured, as it is a dam design standard of 1 Lugeon or less when analyzed, using the results of visual observation and geological map creation during slope cutting. Therefore, in conclusion, it is preferable to make the decision for using RIM grouting on the slope of the dam body structure, based on 1 Lugeon in a rock state, and the cement injection amount also at 1 kg/m.

Evaluation of Shear Elastic Modulus by Changing Injection Ratio of Grout (그라우트 주입률 변화에 따른 전단탄성계수 평가)

  • Baek, Seungcheol;Lee, Jundae;Ahn, Kwangkuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.2
    • /
    • pp.51-55
    • /
    • 2013
  • Among various construction methods, deep soil stabilization by chemical method have been widely used in order to improve soft ground. Dynamic variables using ground(such as sand, weathered granite soil and rock) -structure interaction design affected by dynamic load and cyclic load were studied a lot. However, there is something yet to learn about earthquake resistant design regarding reinforced ground by grout. Therefore, in this study using RC test, the correlation between shear strain and shear modulus with change of water content and injection rate in normal portland cement and clay was compared and analyzed by using Ramberg-Osgood model normalization As the result, dynamic coefficient was considerably affected by water content and grout injection rate.

A Study on Durability and Impermeability of Environmentally Friendly Inorganic Ground Injection Material (환경 친화적인 무기질계 지반주입재의 내구성 및 차수효과에 관한 연구)

  • Chun, Byungsik;Kang, Hyoungnam;Do, Jongnam;Lim, Jooheon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.6
    • /
    • pp.113-119
    • /
    • 2006
  • Recently, the ground injection method using water glasses as one of the main resources and the products of these constructions have basic problems in terms of the method of constructions for the permanent foundation reinforcement and stopping leakage of water because they have some serious problems such as durability, compressive strength, injectant eluviation and so forth even though they are still used to stop leakage of water in the temporary structures. The purpose of this study is to demonstrate the strength characteristic and environment friendliness of NDS method by unconfined compressive strenth test, permeability test, length change test, leaching test, and assessment of environmental impact in comparison water glass type material. The test results show that NDS method has significant improvement of strength, permeability, volume change, and leaching. An assessment of environmental impact also demonstrates that the NDS material is environmentally friendly.

  • PDF

A Study on Seepage Cutoff Effect of the Environmentally Friendly SCM (SCM 친환경주입공법에 의한 차수 효과에 관한 연구)

  • Chun, Byung-Sik;Roh, Jong-Ryun;Jooi, Tae-Seong;Do, Jong-Nam
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.4
    • /
    • pp.65-71
    • /
    • 2005
  • Recently, difficulties in soft ground improvement that caused by effectiveness of the ground improvement, the durability and environmentally friendliness of the injection material come to the fore. This paper studies the field applicability of the SCM in reinforcement and seepage cutoff of the back of an existing continuous wall. SCM uses double rod which imposes heavy pressure($10-100kgf/cm^2$) to disturbed, cut, discharge, and mix the ground. It is observed that a bulb is formed by using cement paste and environmentally friendly injection materials with minimal alkali leaching. Unconfined compression test and fish poison tests are performed. Test results indicate that the method results in higher durability, less leaching through use of the environmentally friendly injection material, and faster mobilization of the strength. In addition, field tests confirm the formation of the bulb and the seepage cutoff wall.

  • PDF

Environmental Test of Avionics Equipment for Lightning Indirect Effect (낙뢰 간접영향에 대한 항공전자장비의 환경시험)

  • Jeong, Duck-young;Yang, Hyun-duck
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.2
    • /
    • pp.55-59
    • /
    • 2013
  • Before avionics equipment are installed in aircraft, several environmental tests such as temperature, vibration, lightning, fire etc. must be conducted. One of the environmental tests is to substantiate protection designs of lightning indirect effect. It can be showed through RTCA DO-160G, section22 "Lightning Induced Transient Susceptibility" test. An additional test of aircraft level is required as well after installation of avionics equipment.

A Case Study on the Improvement of Rail Road Subgrade using Super Injection Grouting Method - Strength Increase in Marine Clay - (철도노반개량을 위한 고압분사 사례연구 - 해성점토지반에서의 강도증대효과를 중심으로-)

  • 천병식;최현석
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.103-110
    • /
    • 1998
  • Several soil improvement methods are applied to stabilize soft ground. But their improvement effects are known to be reduced in view of strength under poor conditions such as marine clay. The purpose of this paper is to investigate the strength increase effects of super injection grouting on the marine clay, A series of laboratory tests and chemical analysis tests has been peformed. Through this study, the causes of strength inferiority of treated soil was analyzed and soil improvement effects of grouted soil was presented.

  • PDF

A Study on the Reinforcement and Environmental Impact of LW Injection (LW주입에 의한 지반보강 및 환경영향성에 관한 연구)

  • Chun, Byungsik;Do, Jongnam;Sung, Hwadon;Lim, Jooheon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.6
    • /
    • pp.121-131
    • /
    • 2006
  • This study is performed to examine the ground reinforcement effect and the environmental impact of LW injection, which is widely used during the excavation of high-rise apartment buildings. In addition, it proved that by conducting field exploration and laboratory test the engineering ground reinforcement effect of LW injection in the ground has low coefficient of permeability. The environmentally friendly aspect was evaluated through an assessment of environmental impact. The results of laboratory test shows that LW coagulating material with SC type soil structure has significant improvement of uniaxial compressive strength, increasing by three times and the shear strength increasing by twice, coefficient of permeability decreasing six to seven times. And the result of environmental impact tests show that from 6 hour after where the pH increases until 7.96 to initially it diminished, it started and to 80 hour after it recovered a pH 7.25 initially with 7.30. The chemical composition analysis test result that unpolluted water and polluted water hydrogen ion concentration (pH) show that the unpolluted water pH 7.36, polluted water pH 7.85, which is inside the Ministry of Environment standard of drinking water (the pH 5.8~8.5). The assessment of environmental impact and chemical analysis test also demonstrate that the LW coagulating material is environmentally friendly. In the $Cr^{6+}$ and the salinity detection test, it was proven that the salinity is slight and the $Cr^{6+}$ is not detected.

  • PDF

Improvement Method of Sand Ground Using an Environmental Friendly Bio-grouting Material (친환경 바이오그라우팅을 이용한 모래지반 개량 공법)

  • Kim, Dae-Hyeon;Sagong, Myung;Park, Kyung-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.6
    • /
    • pp.473-481
    • /
    • 2013
  • The purpose of this research is to evaluate the improvements in the strength and injection range of loose ground after injecting $CaCO_3$(created by microorganism reaction). For this purpose, three cases of single-layer (Sand, SP, SW) specimens were made in a 150mm D ${\times}$ 200mm H space and two cases of multi-layer specimens (SW/SP, SP/SW) were made in a 150mm D ${\times}$ 300mm H space. The specimens were made with a relative density of 30% of soft ground and an injection was given over a time of one day. The uniaxial compression strength was measured with a cone penetrometer and the injection range was observed by checking the bulb formation around the injection nozzle. Also, the compositions of the specimens were assessed through XRD analyses. Based on the test results, a compressive strength of 500kPa and 15cm thick cementation were noted due to the cementation of the soil. This implies that there are significant effects of the pore condition and size on bio-grouting technology.

A Study on the Calculation of Cavity Filling Amount Using Ground Penetrating Radar and Cavity Shaping Equipment (지표투과레이더와 공동형상화 장비를 이용한 공동채움량 산정 연구)

  • Hong, Gigwon;Kim, Sang Mok;Park, Jeong Jun
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.261-268
    • /
    • 2022
  • Purpose: In the case of cavity discovered by ground penetrating radar exploration, it is necessary to accurately predict the filling amount in the cavity in advance, fill the cavity sufficiently and exert strength to ensure stability and prevent ground subsidence. Method: The cavity waveform analysis method by GPR exploration and the method using the cavity shape imaging equipment were performed to measure the cavity shape with irregular size and shape of the actual cavity, and the amount of cavity filling of the injection material was calculated during rapid restoration. Results: The expected filling amount was presented by analyzing the correlation between the cavity size and the filling amount of injection material according to the cavity scale and soil depth through the method by GPR exploration and the cavity scale calculation using the cavity shaping equipment. Conclusion: The cavity scale measured by the cavity imaging equipment was found to be in the range of 20% to 40% of the cavity scale by GPR exploration. In addition, the filling amount of injection material compared to the cavity scale predicted by GPR exploration was in the range of about 60% to 140%, and the filling amount of the injection material compared to the cavity size by the cavity shaping equipment was confirmed to be about 260% to 320%.