• 제목/요약/키워드: Ground Fault Detection

검색결과 74건 처리시간 0.022초

태양광 발전용 직류 지락 검출장치 (DC Ground Fault Detection System for Photovoltaic Generation)

  • 장수진;이정민;김왕문;구태홍;서인영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.408-411
    • /
    • 2008
  • In this paper, a new DC ground fault detection system is proposed, which is suitable for photovoltaic power generation systems. The proposed ground fault systems is superposition of divide resistance and detection circuit. The proposed system has the characteristics of a simplified structure, reduced cost and volume compared with those of the conventional ground fault system for DC source. The operation principle of the proposed systems is described and verified by simulation result.

  • PDF

전기동력 자동차 구동부와 제어부 간 절연고장 검출 방법 (The Method for detecting ground fault between power part and controller part of a electricity vehicle)

  • 박현석;조세봉;전윤석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.174-176
    • /
    • 2007
  • Because of accident or leak of electricity, high voltage electricity can be conducted to vehicle chassis and damage human. Therefore the unit for detecting ground fault is necessary to minimize loss of life or equipment damage. Isolation resistance must be monitored for detecting ground fault. GFD(Ground Fault Detection) unit continually generate the pulse voltage between high voltage network and chassis. This will be sensing the returned current, calculate the isolation resistance and make decision the ground fault. This paper describes the method detecting ground fault.

  • PDF

전기 구동 차량의 누설 전류 검출 기법 (The Method for detecting leakage current of a electric vehicle)

  • 박현석;엄정용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.139.1-139.1
    • /
    • 2011
  • Electric vehicle use independent electricity of high voltage. if isolation of electricity is destructed, devices and people are considerably damaged. Therefore, detection of ground fault is necessary for electric vehicle. As the existing detection method of ground fault can not detect ground fault when isolation of both positive side and negative side of electricity is destructed, and change of voltage of electricity. This paper proposed detection method for ground fault of both two sides of electricity and change of voltage. The proposed method is verified by analysis of equivalent circuit.

  • PDF

누전, 아크, 과부하에 의한 전기화재 제어 시스템 보드의 구현 (The Implementation of the system-on-board controllable the electrical fires due to ground fault, arc fault and overload)

  • 김병철;전중창
    • 한국정보통신학회논문지
    • /
    • 제15권2호
    • /
    • pp.419-424
    • /
    • 2011
  • 누전, 아크 그리고 과부하로 인한 전기화재를 탐지하고 제어할 수 있는 시스템보드(system- on-board)를 구현하였다. 이를 위하여 화재방지제어 시스템 IC를 사용하였으며, 누설전류 검출을 위한 GF(ground fault)신호 검출회로, 아크(arc fault)신호 검출회로, 그리고 과전류가 발생할 경우 입력전압을 제어할 수 있는 과부하신호 검출회로를 설계하였다. GF신호 검출회로와 아크신호 검출회로는 누설전류와 아크신호에 각각 잘 동작하였으며, 과부하(overload) 신호 검출회로는 노이즈나 부하변동에 따른 오동작 없이 과부하시에만 동작함을 확인하였다.

비접지 LVDC 배전망의 지락고장 검출을 위한 분석 (Analysis for Pole to Ground Fault Detection in Ungrounded LVDC Distribution Network)

  • 박철원
    • 전기학회논문지P
    • /
    • 제67권3호
    • /
    • pp.119-124
    • /
    • 2018
  • Recently, LVDC distribution network and DC microgrid with many advantages are being built. However, this LVDC distribution is an IT grounded or ungrounded system, and it is difficult to detect a ground fault because the fault current is small. In this paper, we propose a signal injection method for unipolar LVDC distribution network to detect ground fault in ungrounded LVDC distribution, and various analyzes were performed for ground fault detection.

웨이브렛 변환을 이용한 철도 고압배전선로의 고장검출기법 (Fault Detection Technique in Railway High Voltage Distribution Lines using Wavelet Transform)

  • 정호성;한문섭;이장무;김주락;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1274-1279
    • /
    • 2004
  • This paper proposes technique to detect ground fault in railway high voltage distribution lines. Overcurrent relay technique is widely used for detecting one line ground fault that occurs most frequently in railway high voltage distribution lines. However, ground fault in distribution line is usually high impedance fault with arc. Because the fault current magnitude measured in substation is very small, the conventional overcurrent relay can't detect the high impedance ground fault. Therefore this paper proposes the advanced technique using wavelet transform. It extracts D1 component from fault signals and detects fault comparing magnitude of D1 component in each phase. To evaluate this proposed technique, we model distribution system using PSCAD/EMTDC and extract various fault data. In conclusion this technique can detect ground fault including high impedance fault regardless of fault distance, fault impedance etc.

  • PDF

비접지 배전계통 지락고장 검출 알고리즘 및 프로그램 개발 (Development of Algorithm and Program for the Ground Fault Detection in Ungrounded Distribution Power System)

  • 박소영;신창훈
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2619-2627
    • /
    • 2009
  • 비접지 배전계통에서 전체고장의 약 70%를 차지하는 지락고장 발생시에는 지락전류가 작아 검출이 어렵지만 고장상태로 전원 공급을 지속할 경우 사고 파급 및 기기 소손을 유발할 가능성이 있기 때문에 지락고장 처리는 매우 중요하다. 본 논문에서는 GPT(접지형 계기용 변압기, Ground Potential Transformer)에서 감지하는 영상전압 신호를 이용하여 고장선로를 검출하고, 비상시 연계선로를 이용하여 정전구역을 복구하기 위해 평상시 개폐기가 열려 있는 상태로 배전선로 사이를 연결하는 상시개방점을 이동하며 각 구간을 차례로 분리하면서 GPT 신호의 사라짐 여부를 감시하여 고장구간을 검출하는 방법을 제안한다. 고장구간 탐색 시 전체 정전이 없고, 고장구간 검출과 건전구간 복구가 동시에 가능하며 다양한 형태의 배전계통 구성에 적용 가능하다는 점에서 효율적이다. 본 논문에서 제안하는 고장처리 방법을 프로그램으로 개발하여 베트남 배전자동화 시범사업에 적용함으로써 알고리즘 및 프로그램의 적정성을 검증하였다.

그라운드 바운스 영향과 지연고장을 위한 최소화된 테스트 패턴 생성 기법 (A Minimized Test Pattern Generation Method for Ground Bounce Effect and Delay Fault Detection)

  • 김문준;이정민;장훈
    • 대한전자공학회논문지SD
    • /
    • 제41권11호
    • /
    • pp.69-77
    • /
    • 2004
  • 본 논문에서는 ground bounce 영향과 지연고장 검출을 함께 고려한 효율적인 보드레벨 연결선 테스트 생성 알고리즘을 제안한다. 제안된 알고리즘은 IEEE 1149.1의 연결선 테스트, ground bounce 영향에 의한 바운더리 스캔의 오동작 방지, 그리고 연결선의 지연고장 검출 능력을 포함한다. 본 논문에서 제안하는 기법은 기존의 기법에 비해 연결선의 지연고장 검출능력을 새롭게 추가하였지만, 연결선 테스트에 필요한 총 테스트 패턴 수는 기존의 기법과 비교해서 큰 차이를 보이지 않음을 실험결과에서 확인할 수 있다.

신경회로망과 DWT를 이용한 고장표시기의 고장검출 개선에 관한 연구 (A Study for the Improvement of Fault Detection on Fault Indicator using DWT and Neural Network)

  • 홍대승;임화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.46-48
    • /
    • 2007
  • This paper presents research about improvement of fault detection algorithm in FRTU on the feeder of distribution system. FRTU(Feeder Remote Terminal Unit) is applied to fault detection schemes for phase fault, ground fault, and cold load pickup and Inrush restraint functions distinguish the fault current and the normal load current. FRTU is occurred FI(Fault Indicator) when current is over pick-up value also inrush current is occurred FRTU indicate FI. Discrete wavelet transform(DWT) analysis gives the frequency and time-scale information. The neural network system as a fault detector was trained to discriminate inrush current from the fault status by a gradient descent method. In this paper, fault detection is improved using voltage monitoring system with DWT and neural network. These data were measured in actual 22.9kV distribution system.

  • PDF

비접지 계통에서 영상전류 위상을 이용한 개선된 보호협조 방안 (The Advanced Protection Coordination Scheme using Phase Angle of Zero-Sequence Current in Ungrounded System)

  • 최영준;임희택;최면송;이승재
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.19-25
    • /
    • 2010
  • Most faults are single-phase-to-ground fault in ungrounded system. The fault currents of single-phase-to-ground are much smaller than detection thresholds of measurement devices, so detecting single-phase-to-ground faults is difficult and important in ungrounded system. The protection coordination method using SGR(Selective Ground Relay) and OVGR(Overvoltage Ground Relay) is generally used in ungrounded system. But this method only detects fault line and it has the possibility of malfunction. This paper proposed to advanced protection coordination method in ungrounded system. The method just using zero-sequence current can detect fault line, fault phase, fault section at terminal device. The general protection method is used to back up protection. In the case study, the proposed method has been testified in demo system by Matlab/Simulink simulations.