분리된 삼상 자속구속형 전류제한기와 일체화된 삼상 자속구속형 전류제한기의 전류제한 특성 비교 (Comparison of Fault Current Limiting Characteristics between the separated Three-phase Flux-lock Type SFCL and the Integrated Three-phase Flux-lock Type SFCL)

  • 두승규;두호익;김민주;박충렬;김용진;이동혁;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제22권8호
    • /
    • pp.689-693
    • /
    • 2009
  • We investigate the comparison of fault current characteristics between the separates three-phase flux-lock type superconducting fault current limiter(SFCL) and integrated three-phase flux-lock type superconducting fault current limiter(SFCL). The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core and superconducting elements are connected to secondary coil in series. Superconducting elements are used by the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. But the integrated three-phase flux-lock type SFCL consists of three-phase flux-reactors wound on an iron core. Flux-reactor consists of the same turn's ratio between coil 1 and coil 2 for each single phase. To compare the current limiting characteristics of the separated three-phase flux-lock type SFCL and integrated three-phase flux-lock type SFCL, the short circuit experiments are carried out fault condition such as the single line-to-ground fault. The experimental result shows that fault current limiting characteristic of the separated three-phase flux-lock type SFCL was better than integrated three-phase flux-lock type SFCL. And the integrated three-phase flux-lock type SFCL has an effect on sound phase.

접지선 굵기에 관한 연구 (The study on the ground wire size)

  • 최홍규;최병숙;송영주
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.97-102
    • /
    • 2003
  • Ground in must choose enough sectional area of conductor endurably in maximum fault current, fault duration time, maximum allowable temperature and have strong durability and life-time can bear enough from spontaneous corrosion or electrolytic corrosion and must choose material that problem does not exist electrically and mechanically when connection or junction. In this paper, modeled new ground wire size numerical formula, and examine and compare of modeled numerical formula and abroad regulation, and proved and analyzed validity of the new ground wire size computation method because do simulation to computer program.

  • PDF

전력계통의 지락사고에 대한 매트릭스형 초전도 한류기의 동작특성 (Analysis Operating Characteristics of Matrix-Type Superconducting Fault Current Limiter in Ground Faults of Power Grid)

  • 오금곤;조용선;최효상;오성보;김덕구
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.14-20
    • /
    • 2009
  • 전력 계통 내에서 발생하는 과도한 고장전류의 억제를 위한 가장 이상적인 방안은 초전도 한류기이다. 초전도 한류기의 전력계통 적용을 위해 본 논문에서는 전력계통 내에서 발생하는 1선, 2선, 3선 지락사고를 모의하여 매트릭스형 초전도 한류기의 동작 특성 및 소비전력을 분석하였다. 모든 지락사고에 대해 매트릭스형 초전도 한류기는 사고 초기에는 85[%] 이상, 1주기 이후에는 95[%] 이상 고장전류를 제한시킬 수 있다는 것을 확인하였다. 또한 초전도 소자간의 임계특성의 차이를 줄여줌으로써 소비전력이 균등해진다는 것을 확인하였다.

접지방식이 상이한 철도배전계통의 연장급전을 위한 전기적 특성분석 (Analysis of electric characteristics for extension power supply between different grounding railway distribution system)

  • 정호성;한문섭;이장무;권삼영;박현준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.736-741
    • /
    • 2005
  • This paper presents electric characteristics analysis and safe configuration for extension power supply between existent 6.6kV ungrounded distribution system and establishment and improvement 22.9kV direct grounding distribution system. For this, we model 6.6kV ungrounded and 22.9kV direct grounding distribution system of urban underground, ground region. and rural electrical, unelectrical region using PSCAD/EMTDC and analyze voltage drop, charging current, ground and short fault through simulation. To analyze electric characteristics of extension power supply, we simulate extension power supply of overhead line of 6.6kV ungrounded system and underground line of 22.9kV direct grounding system of rural electrical region and propose operation condition for safe extension power supply through result of analysis. Characteristics of voltage drop, charging current, ground and short fault appear almost similarly with electrical characteristic of direct power supply. However, because unbalance of phases may cause relay's malfunction of ungrounded system and ground fault current of direct grounding system may demage facilities of ungrounded system, we propose safe system configuration such as impedance grounding system of neutral point.

  • PDF

발전소 직류전압 전선로 접지검출시스템에 관한 연구 (A Study on Ground Fault Detecting System for DC Voltage Line in the Electric Power Plant)

  • 이형기;김남호;박찬호;김택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.754-757
    • /
    • 1995
  • This system can detect a ground fault point or a bad insulated line by measuring a power plant DC feeder insulation resistance at the uninterruptible power status. And when the power plant DC feeder with low frequency AC signal has a ground fault, this measuring system can keep recording of its ground fault current and phase checked by Z.C.T. Therefore the power plant could protect a unexpected service interruption.

  • PDF

병행 2회선의 T분기 선로 고장점 표정 알고리즘 (Fault Location Algorithm for Parallel Transmission Line with a Teed Circuit)

  • 권영진;강상희;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.49-51
    • /
    • 2000
  • This paper presents a fault location algorithm for single-phase-to-ground faults on the teed circuit of a parallel transmission line. This algorithm uses only local end voltage and current information. Remote end and fault currents are calculated by using distribution factors. To reduce load current effect, negative sequence current is used. EMTP simulation result have shown effectiveness of the algorithm under various conditions.

  • PDF

고장저항의 영향을 최소화한 순환형 거리계전 알고리즘 (A Recursive Distance Relaying Algorithm Immune to Fault Resistance)

  • 안용진;강상희;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.259-261
    • /
    • 2001
  • An accurate digital distance relaying algorithm which is immune to the combined reactance effect of the fault resistance and the load current is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the apparent impedance, this algorithm uses iteratively the angle of an impedance deviation vector improved step by step. The impedance correction algorithm for ground faults uses a current distribution factor to compensate mutual coupling effect.

  • PDF

주변압기 용량증설에 따른 배전계통의 차단기 정격차단전류 검토 (An Investigation of the nominal rating current for breakers in distribution system due to the increased capacity of power transformer)

  • 조성수;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.396-397
    • /
    • 2008
  • In order to evaluate the nominal rating of breakers in distribution system due to the increased capacity of power transformer from 60 to 100 MVA, the fault currents are calculated in the condition of 3-phase fault and single line-to-ground fault. Consequently, under the condition of the parallel operation of transformers the fault currents were exceed the nominal rating current of breakers in some areas.

  • PDF

리액터의 권선수에 따른 매트릭스형 한류기 최적화 설계 (Optimal Design of Matrix-type SFCLs According to Turn Number of Reactors)

  • 정동철
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1944-1947
    • /
    • 2012
  • In this work, we investigated quench characteristics of matrix-type superconducting fault current limiters (MFCLs) according to the turn number of reactors. The reactors used in MFCLs apply magnetic field to superconducting elements within reactors when fault currents surge into MFCL systems. It makes the fast and simultaneous quenches between superconducting elements. Also reactors decrease the fault power burden of superconducting elements by bypassing the partial fault currents to itself, when quench occurs. These structure proposed in this work can be expected to achieve much more current limiting capacity even though it uses less superconductors compared with other type SFCLs. Three reactors were made by Bakelite. These reactors with the turn number of 190, 380 and 570, had the length of 270 mm and diameter of 80 mm. We reported experimental results, including fault currents, fault voltages and resistance in superconducting elements according to the turn number of reactors. We confirmed that experimental results will be useful in next future plan for the real power grid.

지중케이블 변전소의 고장전류 분류율과 접지전위상승 특성 (Characteristics of Fault Current Division Factor & Groud Potential Rise of a Substation fed exclusively by Power Cables)

  • 최종기;정길조;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.295-297
    • /
    • 1998
  • This paper shows characteristics of fault current division factor $S_f$, which is a ratio of earth- return current to total fault current, at a substation fed exclusively by power cables under unsymmetrical fault condition, such as single line-to-ground fault. In substation grounding system design, $S_f$ is a very important factor determining GPR, touch and step voltage at a substation under fault condition. In case of substations fed by overhead lines, 40-60% of $S_f$ has been typically used, although it is a very conservative value with no other network conditions considered. It is authors' hope that $S_f$ presented in this paper could hopefully be a basic reference in designing of substation grounding system, especially for a substation fed exclusively by power cables.

  • PDF