As the electrical property of fully saturated soils is dependent on the pore water, it has been commonly used for the detection of the contamination into the ground. The objective of this study is to investigate the electrical characteristics according to the salinity and the lead concentration in fully saturated soils. Fresh water and saline water with the salinity of 1%, 2% and 3%, which are mixed with 6 different lead solutions with the range of 0~10 mg/L, are prepared in the cylindrical cell incorporated with sensors for measuring electrical resistance and time domain reflectometry signal. Then, the dried sands are water-pluviated into the cell. The electrical resistance and the time domain reflectometry signal are used to estimate the electrical conductivity. Test results show that electrical conductivity determined from electrical resistance at the frequency of 1 kHz continuously increases with an increase in the lead concentration, thus it may be used for the estimation of the contaminant level. In addition, the electrical conductivity estimated by the time domain reflectometry changes even at very low concentration of lead, the variation rate decreases as the lead concentration increases. Thus, the time domain reflectometry can be used for the investigation of the heavy metal leakage. This study demonstrates that complementary characteristics of electrical resistance and time domain reflectometry may be used for the detection of the leakage and contamination of heavy metal in coastal and marine environments.
In this study, the contaminated status of groundwater under Ponchon Basin, Kwangju-city was analyzed by hydrogeological survey. Though the distribution of groundwater hydraulic head was similar with the ground elevation, the flow system of groundwater was changed due to overpumping in the industrial area. Paddy field and residential area which were located in the north part of the basin had relatively high concentrations of Cl, N $a^{+}$ and N $O_3$$^{[-10]}$ in the groundwater. Southern part of the basin which most industrial area occupied had relatively high concentrations of HC $O_3$, $Ca^{2+}$, $Mg^{2+}$ and Zn. Groundwater was contaminated by C $l^{[-10]}$ and N $O_3$$^{[-10]}$ due to the infiltration of domestic sewage and factory wastewater. In the Cl case, C $l^{[-10]}$ had a tendency of distribution over the water shed along with the contaminated source. The drawdown of groundwater due to overpumping caused more vertical movement of contaminant than lateral movement. If the overpumping continues in the industrial area, the groundwater flow system will be more affected and the groundwater will be lowered in the north part of basin. It is clear that contamination by C $l^{[-10]}$ and N $O_3$$^{[-10]}$ due to domestic sewage and factory wastewater will spread through the whole basin area.rea.
Kim, Hee-Young;Park, Kyung-Ae;Chung, Sung-Rae;Baek, Seon-Kyun;Lee, Byung-Il;Shin, In-Chul;Chung, Chu-Yong;Kim, Jae-Gwan;Jung, Won-Chan
Korean Journal of Remote Sensing
/
v.34
no.1
/
pp.1-15
/
2018
Passive microwave sea surface temperatures (SST) were validated in the Northwest Pacific using a total of 102,294 collocated matchup data between Global Precipitation Measurement (GPM) / GPM Microwave Sensor(GMI) data and oceanic in-situ temperature measurements from March 2014 to December 2016. A root-mean-square (RMS) error and a bias error of the GMI SST measurements were evaluated to $0.93^{\circ}C$ and $0.05^{\circ}C$, respectively. The SST differences between GMI and in-situ measurements were caused by various factors such as wind speed, columnar atmospheric water vapor, land contamination near coastline or islands. The GMI SSTs were found to be higher than the in-situ temperature measurements at low wind speed (<6 m/s) during the daytime. As the wind speed increased at night, SST errors showed positive bias. In addition, other factors, coming from atmospheric water vapor, sensitivity degradation at a low temperature range, and land contamination, also contributed to the errors. One of remarkable characteristics of the errors was their latitudinal dependence with large errors at high latitudes above $30^{\circ}N$. Seasonal characteristics revealed that the errors were most frequently observed in winter with a significant positive deviation. This implies that SST errors tend to be large under conditions of high wind speeds and low SSTs. Understanding of microwave SST errors in this study is anticipated to compensate less temporal capability of Infrared SSTs and to contribute to increase a satellite observation rate with time, especially in SST composite process.
Acid Rock Drainage(ARD) is the product formed by the atmospheric(i.e. by water, oxygen and carbon dioxide) oxidation of the relatively common iron-sulphur mineral pyrite($FeS_2$). ARD causes the acidification and heavy metal contamination of water and soil and the reduction of slope stability. In this paper the generation characteristics and the prediction of ARD of various cut slopes were studied. An attempt to classify the rocks into several groups according to their acid generation potentials was made. Acid Base Accounting(ABA) tests, commonly used as a screening tool in ARD predictions, were performed. Fourteen rock samples were classified into PAF(potentially acid forming) group and four rock samples into NAF(non-acid forming) group. The chemical analysis of water samples strongly suggested that ARD with high content of heavy metals and low pH could pollute the ground water and/or stream water.
As a basic research for developing a sludge application technique in forestry, this study was conducted to investigage a reasonable amount and period of sludge to be applied onto forest nursery of Acer palmatum Thunb. The paper mill sludge was used for the study, and ammonium nitrate was treated to some of them to reduce the C/N ratio lower than 40. The maximum amount of applied sludge was 7ton/ha/year, and they were spread on spring and on late summer. The sludge application did not stimulate early growth of the trees during a year. Since there was no significant changes in soil chemical properties, the amount of applied sludge was thought to be too little to result in a significant role for tree growth. However, the soil water showed significant increase of Cu when the activated sludges were applied during late summer. Thus, the time of application need to be determined cautiously with considering the risk of ground water contamination. In conclusion, if we set a goal from the view point of long-term concept such as forest productivity rather than to get a short-term product, the uncomposted sludge in small amount during growing season might be considered to be applied on forest nursery.
Journal of the Korean Society of Environmental Restoration Technology
/
v.2
no.2
/
pp.24-32
/
1999
To develope appropriate soil base for planting on the artificial ground, 9 kinds of soil types(varying the components and mixing ratios) and 3 levels of soil depths(10cm, 15cm, 20cm) were chosen. And their plant growing effects were tested and analysed from the test plant Zoysia japonica. The results of the research are as follows. 1. Among the 9 type of soil mixtures, the "sandy loam" soil type gave the worst effects on germination, disease contamination and ground covering. 2. The soil types like VSH(vermiculite20%+sand70%+humus sawdust10%), VSS(vermiculite 40%+sand 50%+humus sawdust 10%) and VS(vermiculite 70%+sand 30%), where vermiculite and sand were added to, show better germination effect promoted from the better condition of aeration and saturation. 3. The plant growing effects(leaf length and ground covering ratio) was evident under the soil types like VSH(vermiculite20%+sand70%+humus sawdust10%) and VSS(vermiculite40%+sand50%+humus sawdust10%), where organic matters were added to. 4. Vermiculite added soil types effect fast leaf decolorization on the tested Zoysia japonica plant, on the contrary to organic matter mixed soil types including SCS(sandy loam 50%+carbonized rice husk30%+sand20%) and SHS(sandy loam 50%+humus sawdust30%+sand20%) with which green leaves subsist longer. S. Soil depth effect to plant growth was found. And a favorable covering rate was accomplished even at the soil depth of 15cm - the limit soil depth for grass survival - from the soil types where organic matters were mixed to. From this result, the soil depth limit for plant survival could be said to be shall owed if appropriate soil type were based.
The purpose of this study was to develop an analytical method for determining 15 polycyclic aromatic hydrocarbons (PAHs) of EU priority using gas chromatography (GC)-tandem mass spectrometry (MS). The PAHs in ground coffee were analyzed after being extracted using methods such as saponification-liquid-liquid extraction, Soxhlet extraction, and solid-liquid extraction. The solid-liquid extraction method showed the greatest repeatability and most efficient reduction of the matrix effect. GC-tandem MS for the quantification of the 15 PAHs showed better resolution and lower limit of detections (LODs) than GC-MS-selected ion monitoring (SIM) and high performance liquid chromatography with fluorescence detector. LODs of this method for the ground coffee types were 0.002-0.1 ${\mu}g/kg$ and limit of quantifications (LOQs) were 0.006-0.2 ${\mu}g/kg$ The recoveries ranged from 52.6 to 93.3%. Forty-six commercial types of ground coffee were analyzed to determine their PAHs contamination levels. PAHs concentration ranged from ND to 5.988 ${\mu}g/kg$. This study was conducted with toxicity equivalence factors, the U.S. EPA recommendation to identify dietary risks for PAHs in different types of coffee. The estimated average daily dose of PAHs was $5.24{\times}10^{-8}$ mg/kg body weight/day.
This study was conducted to investigate the degree of ground water pollution used for drinking water in Cheju Island. Samples were collected monthly from 31 wells of 10 divided areas and were analyzed for $NO_3-N$, pH, $SO_4$, Cl and hardness from 1987 to 1992. $NO_3-N$ concentrations in the samples, with the exception of sample No.23, did not exceed the standard concentration of drinking-water(10mg/l). $NO_3-N$ concentrations at area 10, unpolluted area, ranged from <1.0 mg/l to just over 1.2 mg/l. However, samples from the business district of the area 8 showed the concentrations ranging from 5 mg/l in 1987 to 8.l mg/l in 1992 with a mean of 6.8 mg/l, about 5 times higher than those from the area 10. $NO_3-N$ concentration in sample No. 23 increased from 4 mg/l in 1987 to 12.6 mg/l in 1991. Average rate of increase in $NO_3-N$ in samples of No. 1, 2, 4, and 8 at area 8 was about 1.2mg/l per year in the study period. The ground water at area 1, 2, 3, 4, 5, 6, and 7 showed in the range of pH 7 to 8.1, being similar to area 10. However, pH at area 8 was in the range of 6.6 to 7.3, being lower than that in the other areas. Hardness at area 1, 2, 3, 4, 5, and 6 were in the range of 30 to 80 mg/l, being higher than that at area 10. Those at area 8 were the highest among all the other areas tested. The results of this study suggest that $NO_3-N$ contamination in ground water could be a problem at hotel complexes and business district in Cheju Island.
The Narim gold mine is located approimately 200km southeast of Seoul within the Muju mineralized district of the Sobaegsan gneiss complex, Korea. Environmental geochemistry were undertaken for various kinds of water (surface, ground and mine water) collected of April, September and November in 1998 from the narim mine creek. Hydrogeochemical compositions of water samples are characterized by the relatively significant enrichment of Na+K, alkali ions, $HCO_{3}$, $NO_{3}$, Cl and F in groundwater, wheras the mine and surface waters are relatively enriched in Ca+Mg, hea표 metals and $SO_{4}$. Therefore, the groundwaters belong to the (Na+Ca)-( $HCO_{3}+SO_{4}$) type, respectively. The pH and EC values of the non-mining creek surfers are relatively lower compared with those of the surface water of the mine and ore dump area. The d values ($\delta$D-8$\delta^{18}$O) of all kinds of water from the Narim mine creek are 5.8 to 13.1 The range of $\delta$D and $\delta^{18}$O values (relative to SMOW) are shown in distinct two groups as follows: for the April waters of -64.8 to -67.8$\textperthousand$ and -9.6 to -10.0$\textperthousand$(d value=10.1 to 13.1), and for the November waters of -65.9 to -70.2$\textperthousand$ and -9.3 to -9.6$\textperthousand$ (d value=5.8 to 7.9), respectively. This range variation indicates that two group water were composed of distinct waters with seasonal difference. Geochemical modeling showed that mostly toxic metals (As, Fe, Mn, Ni, Pb, Zn) may exist largery in the from of metal $(M2^+)$ and metal-sulfate $(MSO_4\;^{2-$\mid$),\; and \;SO_4^{2-$\mid$}$ concentration influenced the speciation of heavy metals in the meteoric water. These metals in the groundwater could be formed of $CO_3 \;and \;(OH)_3$ complex ions. Using computer program, saturation index of albite, calcite, dolomite in meteoric water show undersaturated and progreddively evolved toward the saturation state, however, ground and mine water are nearly saturated. The gibbsited water-mineral reaction and stabilities suggest that the weathering of silicate minerals may be stable kaolinite, illite and Nasmectite. The clay minerals will be transformed to more stable kaolinite owing to the contiunous reaction.
Recently river water pollution in Korea is given rise to serious problem in aspect of crop production, drinking well, water contamination and etc. Under these urgent situations, it is prime importance to protect water resources from pollutants. An environmental isotope survey of the groundwater form the shallow alluvial and the underlying crystalline rock aquifer of the Han River Basin has been undertaken, Analysis of the data has I) confirmed the hypothesis that the groundwater from the metropolitan area is recharged from the river whereas that form the non-urbanized region of the Basin is replenished by the infiltrating precipitation; ii) shown that crystalline rock aquifers are recharged by the ground water form the overlying alluvium. Old groundwater is a group of wells with tritium values in the range of 0 to 2 TU. These low values indicate that the water sampled was recharged much ealier, at least a few decades, than the other groundwater samples of higher tritium content. The low values in this region may, in fact, reflect the effect of the impermeable clay layers which impede infilteration from the surface. Stable isotope evidence confirmed that a recharge in the karst area occurs at a significantly greater elevation than that to the alluvial aquifer. An analysis of the tritium level collected over an annual cycle suggests that the residence time of groundwater is probably not more than a few months. There does not appear to be any correlation between the trace level of Zn, Mn and Pb in the groundwater and the mechanism of the recharge.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.