• 제목/요약/키워드: Ground

검색결과 22,655건 처리시간 0.042초

유출지하수열원 지열히트펌프의 냉난방성능 (Cooling and Heating Performance of Ground Source Heat Pump using Effluent Ground Water)

  • 박근우;남현규;강병찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.434-440
    • /
    • 2007
  • The Effluent ground water overflows in deep and broad ground space building. Temperature of effluent ground water is in 12$\sim$18$^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is 800$\sim$1000 ton/day. The heat pump capacity is 5RT each. The heat pump system heating COP was 3.0$\sim$3.3 for the open type and 3.3$\sim$3.8 for the close type system. The heat pump system cooling COP is 3.2$\sim$4.5 for the open type and 3.8$\sim$4.2 for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

단동파이프하우스의 지점조건 분석을 위한 실험 연구 (Experimental Study on the Ground Support Conditions of Pipe Ends in Single Span Pipe Greenhouse)

  • 이석건;이종원;곽철순;이현우
    • 생물환경조절학회지
    • /
    • 제17권3호
    • /
    • pp.188-196
    • /
    • 2008
  • 본 연구는 소형 파이프하우스 설계시 구조계산에 필요한 지점조건을 구명하기 위하여 실물크기의 파이프 하우스에 환산된 적설하중 및 풍하중을 재하하여 온실의 붕괴양상과 변위 및 변형도를 측정하였으며, 측정값을 여러 가지 지점조건에 대해 구조해석한 값과 비교 분석하였다. 온실에 작용하는 적설 및 풍하중의 등분포 하중을 집중하중으로 환산할 때 환산된 집중하중의 개수별로 하중효과를 비교 분석한 결과, 적설하중의 경우 최소 2개 이상의 집중하중으로 환산하는 것이, 풍 하중의 경우 각각의 등분포된 수압면의 하중을 1개씩의 집중하중으로 환산하는 것이 등분포하중과 유사한 하중효과가 나타나는 것으로 분석되었다. 변형도의 변화를 분석한 결과 적설하중 작용시에는 예측된 바와 같이 처마부위에서 붕괴된 것으로 나타났으며, 풍하중 작용시에는 풍상측의 처마와 지점부위의 변형이 가장 크게 발생하였고 다음으로 풍하측의 처마와 곡부의 변형이 크게 발생하였으며, 가장 큰 변형을 나타낸 처마가 위험부위로 판단되었다. 응력과 변위에 따른 지점조건을 분석한 결과 지점조건에 따른 변위의 크기는 변위방향과 모델종류에 관계없이 모두 지면고정 <지하고정<지면힌지<지하힌지 순으로 나타났으며, 별도의 기초 없이 서까래를 땅속에 바로 매입하여 설치하는 소형 파이프 하우스의 구조설계시 지점조건을 매입깊이에서의 지하고정으로 하는 것이 바람직할 것으로 판단 되었다.

지반특성에 따른 지중 연성관의 거동특성 (Behavior of Underground Flexible Pipe According to Ground Characteristics)

  • 장용채;김용휴;이승은;박기철;노진숙
    • 한국지반환경공학회 논문집
    • /
    • 제10권4호
    • /
    • pp.41-48
    • /
    • 2009
  • 표준사로 형성된 지반 10cm아래에 연성관을 매설하여 각각의 상대밀도에서 지반거동에 따른 관의 변형을 관찰을 하였다. 지반보강 상태에서의 관의 거동을 파악하기 위하여 지오그리드를 매설관 하부에 설치한 후 각각 지반에서의 관의 변형을 관찰하였다. 관아래 지오그리드를 설치한 후 보강된 지반의 관 변형형태를 관찰하였다. 지오그리드로 보강한 지반은 수직하중이 높아질수록 보강재에 인장력이 형성되어 보강유무에 따른 동일한 수직하중에서 침하가 감소하였다. 상대밀도 100%지반과 70%지반 변형분포가 차이가 나타났다. 보강 70%지반에서는 최종침하 100mm일 때 무보강 100%지반의 최종침하에서의 지반반력에 가깝게 수렴 하였다. 매설관의 하부 변형 형태에서도 무보강 100% 지반의 매설관 변형 형태와 유사한 것으로 보아 연약지반에서 지오그리드의 보강효과가 기대된다.

  • PDF

조경배식에 있어 지피식생조성에 관한 연구 -몽촌토성을 중심으로- (A Study on the Ground Covering in Landscape Planting -In the Case of the Mongchon Earth Fort-)

  • 우종서;이경재
    • 한국조경학회지
    • /
    • 제18권4호
    • /
    • pp.7-16
    • /
    • 1991
  • This research investigated soil, plants, insects and birds in the Mongchon Earth Fort, establishing the 11 plots, according to planting treatment, in order to present management method for ecological stability of species in the ground covering plots. The results of analysizing the investigated data summarize as follows. 1. In the ground covering plots without upper layer, the density and coverage of middle and low layer in the natural plots were higher than those in the artificial plots. 2. In the ground covering plots without upper layer, the density and coverage of low layer were higher than those in the artificial, while the density and coverage of herb layer in the natural plots were lower. 3. Whether there was upper layer or not, the total species diversity and enenness of the ground covering community in the natural plot without artificial treatment and natural treatment plot were higher than those ground covering. 4. In the ground covering plots with upper layer, the species diversity of ground covering in the plots without artificial treatment is high, while the species diversity in the plots with natural treatment caused the secondary succession is higher than that of the natural plot. 5. In the ground covering plots without upper layer, the species diversity in the plots with artificial management was higher than that of natural plots, while the evenness in the plots with artificial management was lower. 6. In the ground covering plots with upper layer the species diversity of insect in the plot of natural state was higher than that of insect in the plots with artifical treatment. 7. Synthetically, in the area with upper layer the species diversity of the ground covering community in the natural plot was high, while in the area without upper layer, the species diversity of it in the plots with artificial treatment was high. The insect turned up frequently in the plots of high species diversity of the ground covering, so the bird did in the plots of high species diversity of the ground covering and insects.

  • PDF

Field and laboratory assessment of ground subsidence induced by underground cavity under the sewer pipe

  • Kong, Suk-Min;Kim, Dong-Min;Lee, Dae-Young;Jung, Hyuk-Sang;Lee, Yong-Joo
    • Geomechanics and Engineering
    • /
    • 제16권3호
    • /
    • pp.285-293
    • /
    • 2018
  • In densely populated urban areas with a large amount of infrastructure, ground subsidence events can result in massive casualties and economic losses. In South Korea, the incidence of ground subsidence in urban areas has increased in recent years and the number of underground cavities suspected of causing such events has significantly increased. Therefore, it is essential to develop techniques to prevent the occurrence of underground and ground subsidence. In this study, a field test, laboratory test, and numerical analysis were conducted to determine the optimal compaction degree of the upper support layer of any underground cavity below the level of sewer pipes in order to prevent such cavities from collapsing and leading to ground subsidence accidents. During the field test, an underground cavity was simulated using ice, and the generation of the cavity was confirmed using ground penetrating radar. The ground investigation was performed using a cone penetration test, and the compaction of the ground where ground subsidence occurred was evaluated with a laboratory test. The behaviour of the ground under various conditions was predicted using a numerical analysis based on the data obtained from the field test and previous studies. Based on these results, the optimal compaction degree of the ground required to prevent the underground cavity from causing ground subsidence was predicted and presented.

심층혼합공법의 최저 개량 심도 결정에 관한 해석적 연구 (An Analytical Study on the Determination of the Lowest Improvement Depth of Deep Mixing Method)

  • 박춘식;송지원
    • 한국지반신소재학회논문집
    • /
    • 제19권1호
    • /
    • pp.35-44
    • /
    • 2020
  • 연약지반 개량 공법 중 심층혼합공법에 대한 설계 기법으로는 복합지반으로 해석하는 방법과 말뚝지반으로 해석하는 방법이 있다. 그러나 이러한 해석에 대한 비교 연구는 부족한 실정으로 설계 시 해석 기준을 명확하게 정의 내리는 것에 어려움이 있다. 본 연구에서는 2차원 및 3차원 해석을 통해 성토 높이와 연약지반의 심도, 보강구간의 치환율을 변화시키며 각 조건별로 복합지반과 말뚝지반을 가정하여 해석하였다. 그 결과 최저 개량 심도는 3차원 해석에 비해 2차원 해석 결과가 6.85~9.08% 더 깊은 결과를 도출하였다. 또한 말뚝지반 해석의 경우 복합지반 해석에 비해 개량 심도는 12.22~14.45% 더 깊은 것을 확인하였다. 이 결과를 통하여 보다 정확한 설계를 위해서는 2차원 해석보다는 3차원 해석을 실시해야 하고, 경제적인 설계를 위해서는 복합지반으로 해석해야 하며, 안정적인 설계를 위해서는 말뚝지반 해석을 실시해야 된다고 판단된다.

지중열전도도 측정과 지중열교환기의 열확산 특성 분석 (Measurement of Ground Thermal Conductivity and Characteristics of Thermal Diffusion by the Ground Heat Exchanger)

  • 정영만;구경민;황유진;장세용;이영호;이동혁;이재근
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.739-745
    • /
    • 2008
  • This paper presents the measurement of ground thermal conductivity and the characteristics of ground thermal diffusion by a ground heat exchanger(GHE). A borehole is installed to a depth of 175 m with a diameter of 150 mm. To analyze the thermal diffusion property of the GHE, thermocouples are installed under the ground near the GHE. The outdoor temperature, the ground temperature, and the water temperature of the GHE are monitored for evaluating the characteristics of ground thermal diffusion. The ground thermal conductivity is evaluated by the in-situ thermal response tester and the line source model. It is found to be 3.08 W/$m^{\circ}C$ in this study. The ground temperature is greatly dependent on the outdoor temperature from the ground surface to 2.5 m in depth and is stable below 10 m in depth. The surface temperature of the GHE varies as a function of the temperature of circulating water. But the ground temperature at 1.5 m far from the GHE is not changed in accordance with the temperature of circulating water.

Simulation method of ground motion matching for multiple targets and effects of fitting parameter variation on the distribution of PGD

  • Wang, Shaoqing;Yu, Ruifang;Li, Xiaojun;Lv, Hongshan
    • Earthquakes and Structures
    • /
    • 제16권5호
    • /
    • pp.563-573
    • /
    • 2019
  • When generating spectrum-compatible artificial ground motion in engineering practices, the effect of the variation in fitting parameters on the distribution of the peak ground displacement (PGD) has not yet drawn enough attention. In this study, a method for simulating ground motion matching for multiple targets is developed. In this method, a frequency-dependent amplitude envelope function with statistical parameters is introduced to simulate the nonstationarity of the frequency in earthquake ground motion. Then, several groups of time-history acceleration with different temporal and spectral nonstationarities were generated to analyze the effect of nonstationary parameter variations on the distribution of PGD. The following conclusions are drawn from the results: (1) In the simulation of spectrum-compatible artificial ground motion, if the acceleration time-history is generated with random initial phases, the corresponding PGD distribution is quite discrete and an uncertain number of PGD values lower than the limit value are observed. Nevertheless, the mean values of PGD always meet the requirement in every group. (2) If the nonstationary frequencies of the ground motion are taken into account when fitting the target spectrum, the corresponding PGD values will increase. A correlation analysis shows that the change in the mean and the dispersion values, from before the frequencies are controlled to after, correlates with the modal parameters of the predominant frequencies. (3) Extending the maximum period of the target spectrum will increase the corresponding PGD value and, simultaneously, decrease the PGD dispersion. Finally, in order to control the PGD effectively, the ground motion simulation method suggested in this study was revised to target a specified PGD. This novel method can generate ground motion that satisfies not only the required precision of the target spectrum, peak ground acceleration (PGA), and nonstationarity characteristics of the ground motion but also meets the required limit of the PGD, improving engineering practices.

지반함몰 사고 분석을 통한 제도 개선안 연구 - 지하시설물 및 주변지반 관리 중심으로 - (Study on Improvement Plan of System through Analysis of Ground Sink Accidents - Focused on the management of underground facilities and their surrounding ground -)

  • 김동진;이종근;김홍균;노태길
    • 한국건설안전학회 논문집
    • /
    • 제3권1호
    • /
    • pp.18-24
    • /
    • 2020
  • 본 연구의 목적은 지반함몰 사고를 예방하기 위한 제도 개선안을 제안하는 것이다. 이를 위해 다음과 같은 수행절차를 따른다. 첫째, 지반침하 및 지반함몰 등의 혼용되어 사용되는 용어를 정의한다. 둘째, 지반함몰 사고 현황 및 원인 분석과 강우량과 지반함몰 원인간의 상관관계 분석을 실시하여 중점관리 원인을 도출한다. 셋째, 중점관리 원인에 대한 제도 개선안을 제안한다. 그 결과, 지하관로 손상과 지하공사 부실이 중점관리 원인으로 규명되었으며, 이를 관리할 두 가지의 제도 개선안을 제시하였다. 본 연구의 결과는 향후 보다 실효성 있는 지하함몰 예방을 위한 제도개선의 기초자료로 활용될 수 있다.