• Title/Summary/Keyword: Groove Width

Search Result 134, Processing Time 0.025 seconds

A Study on Morphology and Size of Clinical Crown of Permanent Maxillary Molar in Korean Adult (한국 성인의 상악 대구치 임상치관의 형태와 크기에 관한 연구)

  • Cha, Kwon-Sil;Oh, Sang-Chun;Dong, Jin-Keum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.79-92
    • /
    • 2000
  • The purpose of this study was to estimate the morphology and the size of permanent maxillary molar in Korean Adult. The 100 dental college students with a normal dentition and without any dental prosthesis and severe caries were selected for this study. The subjects were taken impression to make study model. On the study model, authour three times measured those sizes and estimated morphological structures with a calipers, a Boley gauge and a protractor. The results were as follows; 1. In the maxilary first molar's clinical crown height, mesiolingual cusp height was 6.34mm, mesiobuccal cusp height was 6.05mm, distobuccal cusp height was 5.20mm. And in the maxillary second molar's clinical crown height, mesiobuccal cusp height was 5.85mm, mesiolingual cusp height was 5.71mm, distobuccal cusp height was 5.51mm, distolingual cusp height was 3.53mm. This result considered that the maxillary first molar inclined to distobuccal, and the maxillary second molar more upright than the maxillary first molar. 2. In the width of clinical crown, the maxillary first molar was 10.43mm, the maxillary second molar was 10.20mm, and the difference between the first molar's width and the second molar's width was 0.23mm. 3. The crown thickness was measured divided into mesial buccolingual half and distal buccolingual half. The mesial buccolingual half was 11.14mm, and distal buccolingual half was 10.35mm in the maxillary first molar, and in the maxilary second molar, mesial buccolingual half was 11.25mm, and distal buccolingual half was 9.72mm. This result considered that height of convergency located in mesial half of crown. 4. In the buccal groove length, total length and ratio, the maxillary first molar was 52.5%, the maxillary second molar was 50%. And the development of buccal groove in the maxillary first molar was 59% in case of the well developed buccal groove and 41% in case of the weak developed one. And frequency of buccal pit of the maxillary first molar was 12.5%. Whereas, the frequency of buccal of the well developed buccal groove in the maxillary second molar was 37% and that of the weak developed one was 63%. And frequency of buccal pit of the maxillary second molar was not seen. 5. The 3 cusp type tooth cannot be found in the maxillary first molar and the frequency of 3 cusp type tooth in the maxillary second molar was as small as 6% 6. In the case of 4 cusp type tooth, the size of distal lingual cusp molar was difference between in the maxillary first molar and in the maxillary second molar by about 1mm. 7. The intercuspal distance was similar in the maxillary first premolar and second molar. And intercuspal distanc of mesial half of the maxillary first molar and the maxillary second molar was silmillar, too. 8. The an measurement of occlusal surface in 4 cusp type tooth showed that the angle of occlusal surface between the distobuccal and mesiolingual was an obtuse angle, and the angle of occlusal surface between mesiobuccal and distolingual was an acute angle in the both cases of maxillary first and second molar. 9. The measurements of the development of Carabelli cusp showed that the frequency of the well developed one was 7% and that of the weak developed one was 56% in the maxillary first molar. And there cannot be found the well developed one and can be found 2.5% only in the case of the weak developed one in the maxillary second molar. 10. The well developed oblique ridge in the maxillary first molar showed the 100% frequency and that in the maxillary second molar showed the 85.5% frequency. The frequency of mesiomarginal ridge tubercle in the maxillary first molar was 82% and that in the maxillary second molar was 30.5%. And the frequency of distal accessory tubercle in the maxillary first molar can be seen about 19% and that in the maxillary second molar can be seen about 12%.

  • PDF

FLEXURE STRENGTH OF CAST-JOINED CONNECTOR WITH Ni-Cr-Be ALLOY (주조연결된 니켈-크롬-베릴리움 주조체의 굽힘강도에 관한 비교연구)

  • Jeong, Chang-Mo;Jeon, Young-Chan;Lim, Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.858-866
    • /
    • 1998
  • Soldering is the usual method used to correct an unstable fixed partial denture framework at patient's try-in; However, presoldering base metal alloys is technique-sensitve and results are unstable because it is difficult to maintain uniform heat distribution and to prevent oxidation of an alloy. A cast-joining technique has been developed by Weiss and Munyon for repair, correction and addition to base metal framework. This joining technique eliminates the problem with presoldering of non-precious frameworks. The object of this study was to 1) compare the relative flexure strength and the joining effectiveness of Ni-Cr-Be cast in two pieces and 'pre-soldered' versus in two pieces and 'cast-joined'. 2) determine the effect of increasing the number of retentive grooves on the face of the cast and 3) determine the effect of the relative matched position of groove patterns on flexure strength. The joining effectiveness can be expressed by the ratio of the mean flexure stress of soldered or cast-joined specimens to that of one-piece cast. Resin rods 3mm in diameter were used as pattern of specimens for one-piece casted, presoldered, and cast-joined groups. Cast-joined specimens had two different patterns of retentive grooves on the joined faces. Type A had cross-shaped grooves 1mm in depth. 0.6mm in width. Type B was the same except for the addition of one more retentive groove. In the experiment connecting cast-joined specimens, half of specimens with type A pattern had their patterns on the faces of paired casts matched with each other as mirror image. With the rest pairs, it was proceeded that one of paired casts turned 45 degrees so that the patterns crossed. Half of specimens with type B pattern also had the patterns matched as mirror image; However, here, one of paired casts turned 90 degrees with the other pairs. Retentive groove in this study lacked the intentional undercuts, in contrast with the suggestion of Weiss and Munyon. The specimens were subjected to four-point flexural loading in an Instron testing machine. The midspan flexural stress was calculated at the point of initial plastic strain as determined from a strip-chart recorder or at the point of failure if this occured at a lower stress level. Within the scope of this study, the following results were obtained. 1. The presoldered group showed flexural strength at least 2 times higher than the cast-joined groups. Its joining effectiveness was 82%. 2. In cast-joined groups, the flexural strength of joints with type B patterns exhibited 1.5 times that of joints with type A patterns. Joining effectivenesses were 38% for type B patterns, 25-26% for type A patterns. 3. The relative matched position of groove patterns did not have any significant effect on flexural strength of the cast-joined specimens with either type A patterns or type B patterns(p>.05).

  • PDF

Study on the tribological Properties of Micro-undulated Surface (미세 요철표면의 마찰마멸특성에 관한 연구)

  • 차금환;김대은
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.47-52
    • /
    • 1999
  • In recent years, the micro-tribological behavior of silicon has been the topic of much interest. peformance of thin film under light load is important for potential applications in MEMS. In this work under light load and various humidity, the tribological behavior of undulated surface with various width and shape was Investigated. The results show that undulated surface of linear type had good tribological properties abrasive wear occur depending on the sliding condition. Also the effect of humidity on friction and wear was not important if exist undulation. Finally, undulations on HDD were found to be effective in trapping wear particles.

  • PDF

The Fiber Behavior in Solo-spun Yarn Formation and the Physical Properties of Solo-spun Yarn(2) (Solo spun 방적에서 섬유의 거동과 사의 물리적 성질(2))

  • 박수현;김승진
    • Textile Coloration and Finishing
    • /
    • v.13 no.6
    • /
    • pp.428-434
    • /
    • 2001
  • This study surveys the fiber behavior in yam formation and the Physical properties of Solo-spun yarn. The specimens were made by six types of Solo-spun rollers with fixed twist multiplier In the previous part, the physical properties such as yarn count, evenness, strength, and breaking elongation of these yams were compared with the properties of ring shun yarns and analysed with the mechanism of Solo-spun yarn formation. In the second part of this report, the abrasion resistance and hairiness were discussed wish respect to the micro yarn structures. The narrower the groove width of Solo-spun roller is, the more active the bulk fibers migration is. The Solo-spun film structure has two groups. One is shorter than the others one in longitudinal direction of yarn and has the same structure as ring-spun yarn, which is derided from the smooth zone on the surface of Solo-spun roller. The other one is longer than the former and there are the wrapping fibers. This part is derived from the conflicted grooves on the surface of Solo-spun troller.

  • PDF

The Fiber Behavior in Solo-spun Yarn Formation and the Physical Properties of Solo-spun Yarn(2) (Solo spun 방적에서 섬유의 거동과 사의 물리적 성질(2))

  • Park, Su Hyeon;Kim, Seung Jin
    • Textile Coloration and Finishing
    • /
    • v.13 no.6
    • /
    • pp.70-70
    • /
    • 2001
  • This study surveys the fiber behavior in yarn formation and the Physical properties of Solo-spun yarn. The specimens were made by six types of Solo-spun rollers with fixed twist multiplier In the previous part, the physical properties such as yarn count, evenness, strength, and breaking elongation of these yarns were compared with the properties of ring spun yarns and analysed with the mechanism of Solo-spun yarn formation. In the second part of this report, the abrasion resistance and hairiness were discussed with respect to the micro yarn structures. The narrower the groove width of Solo-spun roller is, the more active the bulk fiber migration is. The Solo-spun yarn structure has two groups. One is shorter than the other one in longitudinal direction of yarn and has the same structure as ring-spun yarn, which is derived from the smooth zone on the surface of Solo-spun roller. The other one is longer than the former and there are the wrapping fibers. This part is derived from the conflicted grooves on the surface of Solo-spun roller.

Laser Marking Process for LCD Light Guide Panel (LCD 백라이트 도광판 제조용 레이저 마킹에 관한 연구)

  • 김경동;백창일;송철기;안성훈
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.79-84
    • /
    • 2003
  • A light guide panel is an element of the LCD backlight module that is often used for the display of compact electronic devices. In this study, a laser marking system is proposed to fabricate light guide panel, which can replace other manufacturing methods such as silk printing, stamping, or v-cutting methods. The objective of this research is to evaluate the process parameters of the laser marking system. Light guide patterns were marked with a 50W $CO_2$ laser (CW) to understand the effects of average power and scanning speed on the geometry and quality of groove pattern. The width of the fabricated grooves increases with increasing laser power and decreasing scan speed. In order to analyze surface characteristics and optical properties (luminance, uniformity), SEM photography and BM7 (luminance measuring system) were used. As a result, the optimal conditions of the process parameters were determined.

Ultrasonographic Diagnosis of the Long Head of Biceps Tendon (이두건 장두의 초음파 진단)

  • Song, Hyun Seok
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.8 no.1
    • /
    • pp.31-37
    • /
    • 2015
  • Lesion of long head of biceps tendon is one of the causes making an anterior shoulder pain. According to the anthropometric study of the bicipital groove the meanings of the width, depth and the medial wall angle were suggested. Confirming the images and location of the long head of biceps tendon itself would be helpful in diagnosis.

  • PDF

Laser-induced etching of GaAs with CFC alternatives (CFC 대체물질을 이용한 GaAs의 레이저 유도 에칭)

  • Park, Se-Ki;Lee, Cheon;Kim, Moo-Sung
    • Electrical & Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.240-245
    • /
    • 1996
  • Non-ozone layer destructive Chlorofluorocarbon(CFC) altematives(CHCIF$_{2}$ and $C_{2}$H$_{2}$F$_{4}$) have been initially used for laser-induced thenrmochemical etching of GaAs. High etching rate up to 188.mu.m/sec and an aspect ratio of 2.7 have been achieved by a single scan of laser beam, respectively. The etching rate at constant ambient gas pressure was found to saturate for beam power. The chemical compositions of the reaction products deposited on the etched groove were measured by Auger electron microscopy(AES). Etched profile, depth and width were observed by scanning electron microscope(SEM).

  • PDF

Incidence and Morphology of Buxtonella sulcata from Cattle in Chonnam Area (전남지방(全南地方) 소의 Buxtonella sulcata 감염실태(感染實態)와 충(蟲)의 형태(形態))

  • Wee, Seong-hwan;Park, Young-jun;Lee, Chung-gil
    • Korean Journal of Veterinary Research
    • /
    • v.26 no.1
    • /
    • pp.157-161
    • /
    • 1986
  • Samples of feces from 1,080 cattle in Chonnam area were examined for Buxtonella sulcata, Of these, 231 cattle (21.4%) were found to be infected with the ciliate. The incidence was higher in the dairy cattle than in the beef cattle. The cysts of the ciliate are almost spherical or sub-spherical and the mean length of $79.58{\pm}11.76{\mu}m$ corresponds quite closely with the mean width of $77.29{\pm}11.41{\mu}m$. The trophozoite is characterized by the position of the cytostome near the open cytopyge and by the curved groove running down from cytostome to the end of the body. Macronuclei of the cyst and trophozoite were only stained green by MFS solution.

  • PDF

The Effect of Solution Treatment on Intergranular Corrosion Resistance of a New Type Ultra Low Carbon Stainless Steel

  • Julin, Wang;Nannan, Ni;Qingling, Yan;Lingli, Liu
    • Corrosion Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.140-146
    • /
    • 2007
  • In the paper, with corrosion velocity measurement and metallographic observation on specimens after sulfuric acid/ferric sulfate boiling experiment, intergranular corrosion tendency of the new type ultra low carbon stainless steel developed by ourselves which experienced solution treatment at different temperatures was evaluated. A VHX 500 super depth field tridimensional microscope was used to observe corrosion patterns on the sample surfaces. The depth and width of grain boundary corrosion groove were measured by the tridimensional microscope, which indicated that the corrosion degrees of the samples which received solution treatment at different temperatures are quite different. Transgranular corrosion at different degree occurred along with forged glide lines. After comparison it was proved that the stainless steel treated at $1100^{\circ}C$ performs very well against intergranular corrosion.