• Title/Summary/Keyword: Groove Depth

Search Result 162, Processing Time 0.017 seconds

A study on the changes of the posterior segments between before, after treatment and postretention period through maxillary expansion therapy (상악궁 확장술을 통한 치료전, 후 및 보정후 상악 구치부 변화에 관한 연구)

  • Park, Tae-Seo;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.55-63
    • /
    • 1997
  • The purpose of thus study was to measure the changes of arch and dentition of maxillary posterior teeth before and after treatment and postretentios in patients treated with Quad-helix. Measurements and analysis were performed on study model with carlipers. Seventeen cases, eight boys and nine girls, were selected with average ages of 12.7 years. Mean retention period was 4 months, and mean wearing time was. 127 days. The result were as follows 1. The interpremolar widths and intermolar width were significantly increased in maxillary first piennolar and molar when compared between before and after treatment and postretention. The maxillary second premolar resulted in significant increase in interpremolar between after tretment and post retention. 2. The long axis of maxillary first premolar and first molar accompaning buccal tipping was significant increased before and after Tx and post retention. Significant increase of the lingual inclination of maxillary second premolar was obsered both in before and after Tx, and before Tx and post retention. 3. The distance between the height of tooth contour was significantly increased in the first and second premolar before and after Tx, and was significant increased in the first molar before and after Tx and post retention. 4. Intermolar width at the palatal groove was increased in before and after Tx. and post retention. The palatal depth was significant increased in before and after Tx. In conclusion expansion of maxillary dental arch showed no relapse and results were stable retention

  • PDF

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF