• Title/Summary/Keyword: Grid-connection Operation

Search Result 80, Processing Time 0.032 seconds

A Study on the Estimation of the Resonance Frequency for an Active Damping Technique of Grid Connected Converters (계통 연계형 컨버터의 능동 댐핑을 위한 공진주파수 추정 기능에 관한 연구)

  • Park, Il-Woo;Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.76-84
    • /
    • 2013
  • The renewable energy sources is raising for use of grid connected systems, for which higher power quality requirements are being issued. A grid connected converter requires a LC-filter stage, this one is lightly damped for efficiency constraints. Hence, it is subject to resonance if excited by the converter current harmonics or pre-exciting grid voltage harmonics. In this paper, an active damping technique employing notch filter for damping of the resonance frequency is introduced. This technique doesn't need to additional sensors. In addition, it is simple to apply for various systems. Monitoring of the resonance frequency ensures the stable operation of the proper connection and disconnection of the grid. This paper proposes the estimating method of a resonant frequency to determine the cut-off frequency of the notch filter. This method is validated by both simulation and experimental results.

Design and Characteristics Analysis of a 3 kW Grid-connected Photovoltaic Power Generation System (3 kW 계통연계형 태양광 발전시스템의 설계 및 실증운전특성 분석)

  • Hwang, I.H.;Jeong, S.J.;Ahn, K.S.;Lim, H.C.
    • Solar Energy
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 1998
  • This paper describes a design method and characteristics analysis of the 3 kW grid-connected photovoltaic power generation system to establish the basic application technology of photovoltaic systems. The design specification of a 3 kW photovoltaic power generation system including a DC/AC inverter is suggested to investigate the system performance for grid connection. The results of the demonstration test from February to October show that the system with utilization rate up to 17% has reliable operation characteristics and is useful for peak-shaving of utility power.

  • PDF

A sensitivity analysis about reactive power according to the interconnection distance of wave-offshore hybrid generation system (복합발전 계통연계 시 보상장치 필요성 분석을 위한 거리에 따른 무효전력 민감성 분석)

  • Jung, Seungmin;Yoo, Yeuntae;Song, Sungyoon;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.251-252
    • /
    • 2015
  • The designed hybrid generation system (HGS) not only consider the voltage condition of grid connection point but also do reactive power support according to the transmission system operator's directions. The PCS operation plan in HGS should be supported by precise transferred quantity expectation about reactive power because the system has large physical areas and also be interconnected with grid through long transmission system. Therefore, the realistic measuring process about transferred reactive power quantity by utilizing HGS is required to consider additional compensation plan. In this paper, an reactive power transferred capability of HGS with expected parameter is analyzed, and imposed to the simulation process that is performed on EMTDC environment. Basically, grid information and system characteristics were utilized with Jeju island in Korea, and the performance analysis is carried out based on the composed layout in ongoing project.

  • PDF

The Fundamental Study for Torsional Vibration of Diesel Generator Set connected Electric Power Grids (전력망에 연결된 디젤 발전기 세트의 비틀림 진동에 대한 기초 연구)

  • Kim, Hyujung;Yun, Hyunwoo;Barro, Ronald D.;Lee, Donchool
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.294-297
    • /
    • 2014
  • A Shipboard power system consists of three or four diesel generator sets connected to a grid. In case of dual fuel diesel generator sets employed LNG ship as a prime mover, large amounts of electricity are required for electric propulsion, auxiliary machinery and accommodation facilities. The electrical connection between generators through a network, torsional vibration can lead power swings. In this paper, the influence on the network by the torsional vibration of diesel generator sets in grid operation were studied. The torsional vibration characteristics were investigated and analyzed through theoretical analysis and the vibration measurement and the results were presented.

  • PDF

A Design for a Fuzzy Logic based Frequency Controller for Efficient wind Farm Operation (풍력발전단지의 효율적 운영을 위한 퍼지로직 기반 주파수 제어기 설계)

  • Kim, Se Yoon;Kim, Sung Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2014
  • Recently wind energy penetration into power systems has increased. Wind power, as a renewable energy source, plays a different role in the power system compared to conventional power generation units. As long as only single and small wind power units are installed in the power system, wind power does not influence power system operation and can easily be integrated. However, when wind power penetration reaches a significantly high level and conventional power production units are substituted, the impact of wind power on the power system becomes noticeable and must be handled. The connection of large wind turbines and wind farms to the grid has a large impact on grid stability. The electrical power system becomes more vulnerable to and dependent on wind energy production, and therefore there is an increased concern about the large wind turbines impact on grid stability. In this work, a new type of fuzzy logic controller for the frequency control of wind farms is proposed and its performance is verified using SimWindFarm toolbox which was developed as part of the Aeolus FP7 project.

Voltage Measurement Accuracy Assessment System for Distribution Equipment of Smart Distribution Network

  • Cho, Jintae;Kwon, Seong-chul;Kim, Jae-Han;Won, Jong-Nam;Cho, Seong-Soo;Kim, Juyong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1328-1334
    • /
    • 2015
  • A new system for evaluating the voltage management errors of distribution equipment is presented in this paper. The main concept of the new system is to use real distribution live-line voltage to evaluate and correct the voltage measurement data from distribution equipment. This new approach is suitable for a new Distribution Management System (DMS) which has been developed for a distribution power system due to the connection of distributed generation growth. The data from distribution equipment that is installed at distribution lines must be accurate for the performance of the DMS. The proposed system is expected to provide a solution for voltage measurement accuracy assessment for the reliable and efficient operation of the DMS. An experimental study on actual distribution equipment verifies that this voltage measurement accuracy assessment system can assess and calibrate the voltage measurement data from distribution equipment installed at the distribution line.

Development of Power Conditioning System for High Power Fuel Cell System (대용량 연료전지 발전시스템용 전력변환기 개발)

  • Kang, Ho-Hyun;Lee, Jin-Hee;Baek, Seung-Taek;Jung, Hong-Ju;Chung, Joon-Mo;Suh, In-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.153-156
    • /
    • 2007
  • This paper presents the design, development and performance of a power conditioning system (PCS) for application to a 250kW Molten Carbonate Fuel Cell (MCFC) generation system. A DSP controller was used to control the dc-dc and dc-ac converter operation for grid connection and power injection to the grid. The controller must also supervise the total PCS operation while communicating with the fuel cell system controller. A control method for parallel operation of dc-dc converters was proposed and verified. A 250kW prototype was successfully built and tested. Experimental performances are compared to minimum target requirements of the PCS for MCFC.

  • PDF

Study of Wind Farm Model Configuration for WFMS simulation (WFMS 모의를 위한 풍력발전단지 모델 구성 연구)

  • Kim, Hyunwook;Jung, Seungmin;Hwang, Pyeong-Ik;Yoo, Yeuntae;Song, Sungyoon;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.247-248
    • /
    • 2015
  • Wind turbines causes instabilities on the grid as their penetration increase. To mitigate harmful effects from wind turbines, transmission system operator(TSO) set up some requirements to obligate for wind generation operator for grid connection. So wind farm management system(WFMS) has important role to follow requirement from TSO, WFMS calculates available real power by considering wake effects, and dispatches real power order to each wind turbine in wind farm to optimize for decreasing load fatigue. To verify operation of WFMS, real-time simulator(RTS) is necessary. This paper deals with RTS configuration to verify WFMS operation. RTS includes wind farm model and power flow code. Normally, wind farm equivalent simple model makes wind turbines in wind farm to one wind turbine mode which cannot verify power flow in wind farm and WFMS operation. Thus, this paper makes wind farm model using simple wind turbine model with transfer function. Matlab is used for make power flow code and wind farm model to impose RTS and those model is certified by PSCAD/EMTDC.

  • PDF

Design of a control scheme for applying DC power sources to a distribution system (배전시스템에 DC 전력원을 적용하기 위한 제어 기법 설계)

  • Hwang, Chul-Sang;Kim, Gyeong-Hun;Byeon, Gilsung;Jeon, Jin-Hong;Jo, Chang-Hee;Park, Minwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1056-1057
    • /
    • 2015
  • A common DC bus is a useful connection for several DC output sources such as photovoltaic (PV), fuel cells, and batteries. Operation of the common DC power system with more than two DC output sources, especially in a stand-alone mode, requires a control scheme for the stable operation of the system. In this paper, a control scheme has been developed for applying DC power sources to the distribution system. The purpose of the control scheme is to make the best use of the DC power sources. The DC power system consists of PV, two energy storage systems and a DC-AC inverter with the control scheme. A distribution system was modeled in PSCAD/EMTDC. As the results, the control scheme is applied to the DC-AC inverter and the DC-DC converter for transfer operations between the grid-connected and the stand-alone mode to keep the DC bus and the AC voltage constant. The results from the simulation demonstrate the stable operation of a grid connected DC power system.

  • PDF

Development of Power Conditioning System for High Power Fuel Cell System (대용량 연료전지 발전시스템용 전력변환기 개발)

  • Lee, Jin-Hee;Baek, Seung-Taek;Jung, Hong-Ju;Kang, Ho-Hyun;Chung, Joon-Mo;Suh, In-Young
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.530-532
    • /
    • 2007
  • This paper presents the design, development and performance of a power conditioning system (PCS) for application to a 250kW Molten Carbonate Fuel Cell (MCFC) generation system. A DSP controller was used to control the dc-dc and dc-ac converter operation for grid connection and power injection to the grid. The controller must also supervise the total PCS operation while communicating with the fuel cell system controller. A control method for parallel operation of dc-dc converters was proposed and verified. A 250kW prototype was successfully built and tested. Experimental performances are compared to minimum target requirements of the PCS for MCFC.

  • PDF