• 제목/요약/키워드: Grid-connection Operation

검색결과 80건 처리시간 0.023초

Novel Topology and Control Strategy of HVDC Grid Connection for Open Winding PMSG based Wind Power Generation System

  • Zeng, Hengli;Nian, Heng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.215-221
    • /
    • 2014
  • To satisfy the high voltage direct current (HVDC) grid connection demand for wind power generation system, a novel topology and control strategy of HVDC grid connection for open-winding permanent magnet synchronous generator (PMSG) based wind power generation system is proposed, in which two generator-side converter and two isolated DC/DC converters are used to transmit the wind energy captured by open winding PMSG to HVDC grid. By deducing the mathematic model of open winding PMSG, the vector control technique, position sensorless operation, and space vector modulation strategy is applied to implement the stable generation operation of PMSG. Finally, the simulation model based on MATLAB is built to validate the availability of the proposed control strategy.

인버터 기반 신재생 에너지 발전 시스템의 계통 지원 운전을 위한 계통 전압 검출 방법 (A Detection Method of Grid Voltage for Grid Support Operation of an Inverter-based Renewable Energy Generation System)

  • 안현철;송승호
    • 신재생에너지
    • /
    • 제9권2호
    • /
    • pp.51-57
    • /
    • 2013
  • The Grid code is being strengthen as increase of renewable energy ratio. Especially, the grid connection regulations are continuously being updated for stable operation of power grids. Static grid support and Dynamic grid support must make an accurate measure at Grid connected point because they needs control algorithm individually. It has to exactly measure voltage including switching ripple at the output of the inverter generating system. In addition, it is necessary to have an accurate voltage measurement when the situation rapidly changing the grid impedance is caused by the input of serial impedance of transformer and line impedance as well as Grid Fault Device. In this paper, We propose a new detection method of grid voltage to calculate accurately the r.m.s voltage of the grid connection point along the standard required by the low voltage regulation. We verified performance through simulation grid fault device.

Sag와 Swell에 따른 계통 이상 검출에 관한 연구 (The Study of Grid Fault Detection for Sag, Swell)

  • 김민기;노용수;김준구;정용채;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.471-472
    • /
    • 2013
  • When ESS(Energy Storage System) is under normal operation, island situation can be occur because of grid accidents. When island operation occur, the system mode switches in to UPS(Uninterruptible Power Supply) mode to supply stabled load power. To decide island operation, checking grid magnitude or frequency is general. But regulation for sag and swell is required. In this paper, it proposes grid connection error detection algorithm for UPS operation when sag and swell occurs in grid, and analyzed by simulation.

  • PDF

풍력발전 계통연계 평가기준 연구 (Study of Power System Impact Assessment Standard for Large-scale Wind Farms)

  • 최영도;전영수;박영신;전동훈;윤기갑;박상호;신정훈;이재걸
    • 신재생에너지
    • /
    • 제6권1호
    • /
    • pp.12-19
    • /
    • 2010
  • In Korea, experiences in wind farm operation are limited and the foundation for setting standards in electrical system connection is still weak in comparison to the operation experience in connection of wind power to the electrical system of other countries around the world. Therefore, standards that are being applied in various countries for connection and optimal operation in wind farms need to be examined, and in addition, procedures for the assessment of the effects on the system are needed for setting connection standards and optimal operation plans in accordance with Korean electrical system characteristics. In this study, procedures for the assessment of effects of wind power connection to the electrical system are presented.

제주계통 풍력발전단지의 무효전력 특성 분석 (Analysis of Reactive Power Characteristic for Wind Farms in Jeju System)

  • 최영도;박영신;전동훈;윤기갑;박상호
    • 신재생에너지
    • /
    • 제6권2호
    • /
    • pp.19-26
    • /
    • 2010
  • Experiences in wind farm operation are very limited in Korea, and the foundation for setting standards in power system connection is weak. Therefore, connection and operation standards for wind farms in other countries must be reviewed and power system operation criteria need to be established in order to set up connection standards and optimal operation plans according to the Jeju power system. In this study, reactive power control characteristics of a wind farm were analyzed using a wind farm model of the Jeju power system to propose power system connection operation standards for wind generation within the Jeju power system. Also, change in characteristics of the power system for the application of each reactive power control standard was confirmed, and the results were verified through trial tests arm was analyzed.

동기기를 사용한 계통연계형 가변속 풍력발전 시스템의 AC-DC-AC 컨버터 구현 및 제어 (Implementation and Control of AC-DC-AC Power Converter in a Grid-Connected Variable Speed Wind Turbine System with Synchronous Generator)

  • 송승호;김성주;함년근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권12호
    • /
    • pp.609-615
    • /
    • 2005
  • A 30kW electrical power conversion system is developed for a variable speed wind turbine. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and the frequency of the generator output vary according to the wind speed, a 6-bridge diode rectifier and a PWM boost chopper is utilized as an ac-dc converter maintaining the constant dc-link voltage with only single switch control. An input current control algorithm for maximum power generation during the variable speed operation is proposed without any usage of speed sensor. Grid connection type PWM inverter converts dc input power to ac output currents into the grid. The active power to the grid is controlled by q-axis current and the reactive power is controlled by d-axis current with appropriate decoupling. The phase angle of utility voltage is detected using software PLL(Phased Locked Loop) in d-q synchronous reference frame. Experimental results from the test of 30kW prototype wind turbine system show that the generator power can be controlled effectively during the variable speed operation without any speed sensor.

PMSG를 이용한 풍력 발전 시스템의 3병렬 운전과 계통 연계 기술 (Three-Parallel System Operation and Grid-Connection Technique for High-Power Wind Turbines using a PMSG)

  • 이상혁;정해광;이교범;최세완;최우진
    • 전력전자학회논문지
    • /
    • 제15권4호
    • /
    • pp.296-308
    • /
    • 2010
  • 본 논문은 영구자석형 동기발전기를 이용한 풍력발전 시스템의 3병렬 운전과 계통연계 기술을 제안한다. 영구자석형 풍력발전 시스템에서 back-to-back 컨버터는 발전기와 계통에 직접 연결되므로 시스템 정격에 준하는 전력 반도체 소자와 필터가 요구된다. 본 논문은 시스템의 전력변환부를 3병렬로 연결하고 병렬 운전에 의해 발생할 수 있는 순환 전류는 적절한 내부 인덕터 선정으로 해결한다. 낮은 스위칭 주파수로 운전되는 대용량 풍력발전 시스템의 THD 규정을 만족시키기 위해 최적 설계된 LCL필터를 사용하고 LCL필터에 의해 발생할 수 있는 공진 문제는 전력이론을 통한 능동 댐핑 기법을 통하여 추가적인 손실 없이 보상한다. 또한 계통 왜곡 및 불평형 시 발생할 수 있는 전력 품질의 문제는 추가적인 보상 알고리즘을 적용하여 향상시킨다. 시뮬레이션 및 실험을 통하여 병렬 운전 시스템과 알고리즘의 타당성을 검증한다.

Performance Prediction & Analysis of MGT Co-generation System

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu;Kim, Jae-Hoon
    • 신재생에너지
    • /
    • 제2권3호
    • /
    • pp.15-22
    • /
    • 2006
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new market penetration using the distributed generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection standards. KEPCO, a government company in Korea, has performed the project to identify and evaluate the performance of Micro Gas Turbine(MGT) technologies focused on 30, 60kW-class grid-connected optimization and combined Heat & Power performance. This paper describes the results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of Exhaust-gas Absorption Chiller was developed, so that it will be able to analyze or propose new distributed generation system using MGT. In addition, KEPCO carried out the field testing of the MGT Cogeneration system at the R&D Center Building, KEPCO. The field test was conducted in order to respond to a wide variety of needs for heat recovery and utilization. The suggested method and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

이산 웨이블렛을 이용한 태양광발전시스템의 단독운전 검출 (Islanding Detection technique using DWT in the PV system)

  • 구자경;서동우;김일송
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.105-106
    • /
    • 2012
  • In this paper, discrete wavelet transform using a PV system covers how the detection of a islanding. Connection point occur exclusively in Grid when the grid voltage and current operation of the wavelet coefficients by changing features will determine if islanding operation. The proposed method has simple computation and fast decision time has the advantage. DSP-based controller through the experiment proved the validity of the proposed method.

  • PDF

배터리 에너지저장이 결합된 계통연계 풍력발전시스템의 운전모드 개발 및 평가 (Operation Mode Development and Evaluation for Grid-Tied PMSG Wind Power System Combined with Battery Energy Storage)

  • 김현준;김도현;김경태;한병문
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.41-49
    • /
    • 2012
  • This paper describes the operation mode development for the grid-tied PMSG(permanent magnet synchronous generator) wind power system combined with a battery energy storage. The development of operation modes was carried out through simulations with PSCAD/EMTDC software and experiments with a 10kW hardware prototype. The detailed simulation models for PMSG wind power system and battery energy storage were developed using user-defined models programed with C-code. A 10kW hardware simulator was built and tested in connection with the local load and the utility power. The simulation and experimental results confirm that the grid-tied PMSG wind power system combined with battery energy storage can supply highly reliable power to the local load in various operation modes.