• 제목/요약/키워드: Grid-connected operation

검색결과 258건 처리시간 0.033초

이중여자 유도발전기를 이용한 가변속운전과 정속운전 풍력발전시스템의 운전특성 비교 (Comparison of Characteristics for Variable Operation using Doubly-fed Induction Generator and Fixed Speed Operation in Wind Turbine System)

  • 노경수;김태호
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1313-1320
    • /
    • 2009
  • This paper analyzes the steady-state operating characteristics of doubly-fed induction generator(DFIG) and fixed-speed induction generator(FSIG) in wind turbine system. It also presents a modeling and simulation of a grid-connected wind turbine generation system for dynamics analysis on MATLAB/Simulink, and compares the responses between DFIG and FSIG wind turbine systems with respect to wind speed variation, 3-phase fault and 1-phase ground fault of the network. Simulation results show the variations of generator's active/reactive output, rotor speed, terminal voltage, fault current, etc. Case studies demonstrate that DFIG illustrates better performance compared to FSIG.

풍력발전 계통연계를 위한 매트릭스 컨버터의 개발 (Development of Matrix Converter for Grid-Connected Wind Power Generation)

  • 최남섭;리위룽;한병문;고종선;노의철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.208-210
    • /
    • 2007
  • As a renewable power source, wind power generation has been research interest for many years. And power electronic converters have been developed and applied in variable speed wind turbines. This paper presents the basic development and implementation of space-vector modulated three phase AC-AC matrix converter for variable speed wind power system. Basic matrix converter operation is described, where a new bidirectional switch structure with commutation circuit is used. Finally, experiment results of basic converter operation are shown.

  • PDF

계통연계형 태양광발전시스템의 실증시험 분석 (Analysis of Demonstration Research for Grid-connected Photovoltaics System)

  • 박정국;김성결;이강연;조금배;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.205-207
    • /
    • 2004
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration experiment. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for demonstration experiment.

  • PDF

A Control and Protection Model for the Distributed Generation and Energy Storage Systems in Microgrids

  • Ballal, Makarand Sudhakar;Bhadane, Kishor V.;Moharil, Ravindra M.;Suryawanshi, Hiralal M.
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.748-759
    • /
    • 2016
  • The microgrid concept is a promising approach for injecting clean, renewable, and reliable electricity into power systems. It can operate in both the grid-connected and the islanding mode. This paper addresses the two main challenges associated with the operation of a microgrid i.e. control and protection. A control strategy for inverter based distributed generation (DG) and an energy storage system (ESS) are proposed to control both the voltage and frequency during islanding operation. The protection scheme is proposed to protect the lines, DG and ESS. Further, the control scheme and the protection scheme are coordinated to avoid nuisance tripping of the DG, ESS and loads. The feasibility of the proposed method is verified by simulation and experimental results.

The Implementation of Storage Type Power Flow Controller using Battery Storage

  • Leung, K.K.;Sutanto, D.
    • Journal of Power Electronics
    • /
    • 제1권2호
    • /
    • pp.99-106
    • /
    • 2001
  • This paper describes the implementation of a Storage Power Flow Controller (SPFC) connected to the grid which can provide concomitant benefits associated with a Unified Power Flow Controller while at the same time providing several other very important benefits to power system operation such as, load leveling dynamic voltage stability inprovement, harmonic compensation and power factor correction. This Storage power Flow Controller (SPFC) was implemented using real time signal processors, three-phase inverter(s) and battery bank which can provide improved power system operation and control, added system security and reduced power system losses.

  • PDF

멀티 마이크로그리드 최적 운영을 위한 멀티 에이전트 시스템 적용 (Applying Multi-Agent System for Optimal Multi-Microgrids Operation)

  • 부이 반하이;후세인 아크타르;김학만
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2016년도 춘계학술발표대회
    • /
    • pp.464-465
    • /
    • 2016
  • This paper analyzes the capabilities of multi-agent system (MAS) technology for the optimal multi-microgrids (MMGs) operation in grid-connected mode. In this system, communication among microgrids (MGs) is realized by developing a modified contract net protocol (MCNP) based on agent communication language (ACL) messages. Moreover, a two-stage mathematical model is proposed based on mixed integer linear programming (MILP) for local optimization in each MG, and global optimization in energy management system.

시뮬레이션에 의한 PV시스템 설치방식의 최적설계에 관한 연구 (A Study on Optimal Design of PV System Installation by Simulation)

  • 소정훈;유권종;최주엽
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.1-6
    • /
    • 2003
  • This paper compares the operation characteristics of PV(Photovoltaic) system by computer simulation with those of real PV system and the operation characteristics of PV system by computer simulation are evaluated and analyzed considering system parameters of specifications, installation and surrounding conditions etc. From the basis of these results, this study will intend to develop an evaluation, analysis tool and construct database for optimal design of PV system.

Active Use of DFIG-Based Variable-Speed Wind-Turbine for Voltage Control in Power System Operation

  • Ko, Hee-Sang;Yoon, Gi-Gab;Hong, Won-Pyo
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.254-262
    • /
    • 2008
  • This paper presents an active use of doubly-fed induction-generator(DFIG)-based variable-speed wind-turbine for voltage control in power system operation. For reasonable simulation studies, a detail dynamic model of a DFIG-based wind-turbine grid-connected system is presented. For the research objective, an innovative reactive power control scheme is proposed that manipulates dynamically the reactive power from the voltage source converter(VSC) with taking into account its operating state and limits.

외부 배전선 사고에 대한 분산전원 보호 알고리즘의 동작 수준 평가 (Assessment of the Protection Algorithm Applied in Distributed Generations for Faults Occurred in the Interconnected Distribution Networks)

  • 장성일;김세근;박용업;김광호;최정환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.337-340
    • /
    • 2003
  • This paper describes the operational characteristics of protection algorithm applied in distributed generations(DG) for faults occurred in the interconnected distribution networks. The DG can be Influenced by abnormal grid conditions such as disturbances occurring in the neighboring distribution feeders as well as the interconnected power line. Particularly, in case of the fault happening in the neighboring distribution feeders emanated from the substation to which DG is connected, the protective devices in the DG might mis-operate. The mis-operation of protective devices can be varied by the fault conditions. The simulation results for Hoenggye substation model composed of five feeders using PSCAD/EMTDC showed that the number of mis-operation of protective devices applied in DG is about 0.66 times per one year.

  • PDF

정궤환을 이용한 무효전력 변동기반의 단독운전 방지 성능 검증 (Performance Verification of Anti-Islanding of Reactive Power Variation Method using Positive Feedback)

  • 조종민;신창훈;차한주
    • 전력전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.105-110
    • /
    • 2019
  • This study proposed a reactive power variation (RPV) method equipped with positive feedback (PF) for detecting the islanding operation of distributed generation systems. The proposed RPV consists of the constant reactive power component and a certain reactive power term and uses the frequency deviation between the rated and the measured frequencies. The constant reactive power is injected from distributed generation system and power factor is to 0.9975 in grid-connected operation. PF is activated from generation of the frequency deviation and the injected reactive power is continuously increased due to PF when islanding occurs. Consequently, the increasing reactive power causes the point of common coupling frequency to deviate from the maximum/minimum threshold level. Performance of the proposed RPV is verified in a 1.7 kW T-type inverter, and the detection times are 53 and 150 ms.