• 제목/요약/키워드: Grid-connected control

검색결과 528건 처리시간 0.038초

건물 조명을 위한 PV ESS 동작모드 및 제어기법 (Operation mode and Control method of PV ESS for Building Lighting)

  • 팽성일;박운호;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.118-119
    • /
    • 2017
  • This paper proposes the operation mode and control method of the PV ESS for building lighting. The PV ESS is consisted of 3.3kW single phase grid connected PV inverter, Bi-direction DC/DC converter for Charging/Discharging for battery and DC48V Buck DC/DC converter for LED lighting.

  • PDF

분산전원의 구성 및 출력 제어 방법에 따른 Droop 계수 설정 방법 (A Method to Determine the Droop Constant of DGs Considering the Configuration and Active Power Control Mode)

  • 안선주;박진우;정일엽;문승일
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1954-1961
    • /
    • 2008
  • Microgrid usually consists of a cluster of distributed generators(DGs), energy storage systems and loads, and can operate in the grid-connected mode and the islanded mode. This paper presents detailed descriptions of two different options for controlling the active power of DGs in the microgrid. One is regulating the power injected by the unit to a desired amount(Unit output power control) and the other is to regulate the flow of active power in the feeder where the unit is installed to a constant(Feeder flow control). Frequency-droop characteristics are used to achieve good active power sharing when the microgrid operates in the islanded mode. The change in the frequency and the active power output of DGs are investigated according to the control mode and the configuration of DGs when the microgrid is disconnected from the main grid. From the analysis, this paper proposes a method to determine the droop constant of DGs operating in the feeder flow control mode. Simulation results using the PSCAD/EMTDC are presented to validate the approach, which shows good performance as opposed to the conventional one.

FSIG 풍력발전의 특성개선을 위한 DFIG의 협조 전압제어 (Coordinated Voltage Control of DFIG to Overcome Shortcomings of FSIG in Wind Turbine System)

  • 드옹 민콴;노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.704-705
    • /
    • 2011
  • At present, the widely used wind power generators in the whole world are fixed speed induction generator (FSIG) and doubly fed induction generator (DFIG). The models of FSIG and DFIG wind power generation system connected with the grid are built, and their steady-state and transient characteristics are studied. A new coordinated control strategy using both the grid and rotor side converters of DFIG for voltage regultation and reactive power support is put forword to improve the steady-state and transient performance of the FSIG in the case of DFIG in parallel with FSIG.

  • PDF

마이크로그리드의 운전모드를 고려한 자동발전제어시스템 (Automatic Generation Control System for Operation Mode in Microgrid)

  • 박중성;이학주;채우규;김주용;조진태
    • 전기학회논문지
    • /
    • 제61권7호
    • /
    • pp.928-936
    • /
    • 2012
  • The microgrid concept assumes a cluster of loads and microsources operating as a single controllable system that provides a new paradigm for defining the operation of distributed generation. This system can be operated as both grid-connected mode and islanded mode. In other words, the microgrid can be operated to meet their special need; such as economics in steady state and local reliability in islanded mode due to the grid fault. This paper presents the AGC (Automatic Generation Control) method for microgrid with EMS (Energy Management System).

전원 전압 불평형시 이중여자 유도형 풍력발전 시스템의 토크 리플 저감을 위한 계통연계 인버터 제어 알고리즘 (Grid-connected Inverter Control Algorithm for Torque Ripple Compensation in Doubly-Fed Induction-type Wind Power Generation System)

  • 정병창;송승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.317-319
    • /
    • 2005
  • In this paper, control algorithm for torque ripple compensation in DFIG wind power generation system is proposed. A simple PI controller is designed for the negative sequence voltage cancellation using negative sequence currents in the grid-side converter. As a result, the stator voltage contains only the positive sequence components and the torque pulsation of the generator is effectively compensated. Propose algorithm is confirmed with PSCAD simulation model.

  • PDF

사물인터넷용 소용량 연결 서비스 솔루션 설계 (Design of small-scale connected service solution for Internet of Things)

  • 김삼택
    • 한국융합학회논문지
    • /
    • 제8권9호
    • /
    • pp.25-30
    • /
    • 2017
  • 커넥티드 하우스는 새로운 통신서비스와 M2M, NFC, 스마트 홈, 스마트 그리드 등 기존 IT 시스템을 융합한 새로운 형태의 IT 융합 서비스로서, 언제 어디서나 어떠한 디바이스에도 연결되는 미래형 커넥티드 라이프 서비스이다. 본 논문에서는 미래형 커넥티드 라이프 서비스를 제공하는 사물인터넷용 커넥티드 오피스 솔루션인 지능형 게이트웨이를 설계하여 각종 센서와 지그비/Z-Wave/NFC 및 단말장치를 연동하며 제어할 수 있게 하였다. 또한 본 게이트웨이에 연동되는 IP/SIP/IMS 카메라, 비디오 도어폰을 개발하여 음성품질, 지터, 프레임 스피드 항목에서 국내통신사업자의 품질 기준을 만족하였다.

6 직렬 연결된 ITER VS 컨버터의 시퀀스제어 비교 해석 (Comparative Analysis of Sequence Control in Six Series-Connected ITER VS Converters)

  • 조현식;정진용;조종민;차한주
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.399-406
    • /
    • 2014
  • This study investigates the structure and operation of the ITER VS converter and proposes a sequence control method for six series-connected VS converters to reduce reactive power. The operation and the proposed sequence control method are verified through RTDS simulation. The ITER VS converter must supply voltage/current to the superconducting magnets for plasma current vertical stabilization, and the four-quadrant operation must proceed without a zero-current discontinuous section. The operation mode of the VS converter is separated into a 12- and 6-pulse circulating current and transition modes according to the size of the load current. The output voltage of the unit VS converter is limited because of the rated voltage; however, the superconducting coil must increase the operating output voltage. Thus, the VS converter must be connected in a 6-series to provide the required operating output voltage. The output voltage of the VS converters is controlled continuously; however, reactive power is limited within a minimized value of the grid. In this study, the unit converter is compared with converters connected in a 6-series to determine a suitable sequence control method. The output voltage is the same in all cases, but the maximum reactive power is reduced from 100% to 73%. This sequence control method is verified through RTDS simulation.

전류형 인버터를 이용한 계통 연계형 태양광 발전 시스템에 관한 연구 (Study on Grid-Connected Photovoltaic System using Current-Source Inverter)

  • 임정민;박성준;이상훈;문채주;최준호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.677-681
    • /
    • 2005
  • This Paper presents a 6 pulse shift operation control mode of current-source-inverter to make improvement of efficiency and to reduce the frequency of inverter switching for photovoltaic generation system using PWM current-source-inverter. This system is connected solar cell energy directly without using a storage cell. The proposed circuit can maintain maximum voltage of photovoltaic generation of take advantage of six Buck-Boost converter and a full-bridge inverter determines the polarity of AC output. That is controlled by using digital signal processor TMS320F2812 for operation about a 6 pulse shift operation control of current-source-inverter, and it is verified through the experimental results.

  • PDF

FPGA를 이용한 소형 태양광 발전 니켈 수소 전지 충전 시스템의 POS MPPT 제어 (FPGA based POS MPPT Control for a Small Scale Charging System of PV-nickel Metal Hydride Battery)

  • 이효근;서효룡;김경훈;박민원;유인근
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.80-84
    • /
    • 2012
  • Recently, the small scale photovoltaic (PV) electronic devices are drawing attention as the upcoming PV generation system. The PV system is commonly used in small scale PV applications such as LED lighting and cell phone. This paper proposes photovoltaic output sensorless (POS) maximum power point tracking (MPPT) control for a small scale charging system of PV-nickel metal hydride battery using field-programmable gate array (FPGA) controller. A converter is connected to a small scale PV cell and battery, and performs the POS MPPT at the battery terminal current instead of being at the PV cell output voltage and current. The FPGA controller and converter operate based on POS MPPT method. The experimental results show that the nickel metal hydride battery is charged by the maximum PV output power.

PSCAD/EMTDC를 이용한 고정속 풍력발전시스템 모델링 및 과도상태 안정화기법 (Fixed speed wind power generation system modeling and transient state stabilization method using PSCAD/EMTDC)

  • 김영주;박대진;;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1178-1179
    • /
    • 2008
  • This paper describes a modeling of fixed speed wind power generation system which comprise of wind turbine, generator and grid. The wind turbine is based on MOD-2, which is IEEE standard wind turbine, and includes a component using wind turbine characteristic equation. Fixed speed induction generator is directly connected to grid, so the variation of wind speed has effects on the electrical torque and electrical output power. Therefore the power control mode pitch control system is necessary for aerodynamic control of the blades. But the power control mode does not operate at the fault condition. So it is required some methods to control the rotor speed at transient state for stabilization of wind power system. In this paper, simulation model of a fixed speed wind power generation system based on the PSCAD/EMTDC is presented and implemented under the real weather conditions. Also, a new pitch control system is proposed to stabilize the wind power system at the fault condition. The validity of the stabilization method is demonstrated with the results produced through sets of simulation.

  • PDF