• 제목/요약/키워드: Grid-connected control

검색결과 528건 처리시간 0.026초

LCL 필터를 갖는 3상 계통연계형 인버터의 최적 전류 제어 (Optimal Current Controller in a Three-Phase Grid Connected Inverter with an LCL filter)

  • 이귀준;박남주;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2007
  • This paper presents a robust current control in a three phase grid connected inverter using an LCL filter. This controller is based on the optimal control theory and typically designed in a complex-valued state-space. The proposed current controller has a robust tracking performance for the grid voltage harmonics and robustness to parameter error and load variation. Finally, the simulation results are presented to verify the validity of the proposed method.

  • PDF

3레벨 NPC인버터의 소신호 모델링과 중성점 전압 진동 저감 (A Small Signal Modeling of Three-level Neutral-Point-Clamped Inverter and Neutral-Point Voltage Oscillation Reduction)

  • 조자휘;구남준;정석언;현동석
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.407-414
    • /
    • 2014
  • This study proposes a control design for the grid output current and for reducing the neutral-point voltage oscillation through the small-signal modeling of the three-phase grid connected with a three-level neutral-point-clamped (NPC) inverter with LCL filter. The three-level NPC inverter presents an inherent problem: the neutral-point voltage fluctuation caused by the neutral-point current flowing in or out from the neutral point. The small signal modeling consists of averaging, dq0 transformation, perturbing, and linearizing steps performed on a three-phase grid connected to a three-level NPC inverter with LCL filter. The proposed method controls both the grid output and neutral-point currents at every switching period and reduces the neutral-point voltage oscillation. The validity of the proposed method is verified through simulation and experiment.

A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters

  • Geng, Yiwen;Qi, Yawen;Zheng, Pengfei;Guo, Fei;Gao, Xiang
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1555-1566
    • /
    • 2018
  • Proportional capacitor-current-feedback active damping (AD) is a common damping method for the resonance of LCL-type grid-connected inverters. Proportional capacitor-current-feedback AD behaves as a virtual resistor in parallel with the capacitor. However, the existence of delay in the actual control system causes impedance in the virtual resistor. Impedance is manifested as negative resistance when the resonance frequency exceeds one-sixth of the sampling frequency ($f_s/6$). As a result, the damping effect disappears. To extend the system damping region, this study proposes a virtual resistor-inductor-capacitor (RLC) AD method. The method is implemented by feeding the filter capacitor current passing through a band-pass filter, which functions as a virtual RLC in parallel with the filter capacitor to achieve positive resistance in a wide resonance frequency range. A combination of Nyquist theory and system close-loop pole-zero diagrams is used for damping parameter design to obtain optimal damping parameters. An experiment is performed with a 10 kW grid-connected inverter. The effectiveness of the proposed AD method and the system's robustness against grid impedance variation are demonstrated.

Stationary Frame Current Control Evaluations for Three-Phase Grid-Connected Inverters with PVR-based Active Damped LCL Filters

  • Han, Yang;Shen, Pan;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.297-309
    • /
    • 2016
  • Grid-connected inverters (GCIs) with an LCL output filter have the ability of attenuating high-frequency (HF) switching ripples. However, by using only grid-current control, the system is prone to resonances if it is not properly damped, and the current distortion is amplified significantly under highly distorted grid conditions. This paper proposes a synchronous reference frame equivalent proportional-integral (SRF-EPI) controller in the αβ stationary frame using the parallel virtual resistance-based active damping (PVR-AD) strategy for grid-interfaced distributed generation (DG) systems to suppress LCL resonance. Although both a proportional-resonant (PR) controller in the αβ stationary frame and a PI controller in the dq synchronous frame achieve zero steady-state error, the amplitude- and phase-frequency characteristics differ greatly from each other except for the reference tracking at the fundamental frequency. Therefore, an accurate SRF-EPI controller in the αβ stationary frame is established to achieve precise tracking accuracy. Moreover, the robustness, the harmonic rejection capability, and the influence of the control delay are investigated by the Nyquist stability criterion when the PVR-based AD method is adopted. Furthermore, grid voltage feed-forward and multiple PR controllers are integrated into the current loop to mitigate the current distortion introduced by the grid background distortion. In addition, the parameters design guidelines are presented to show the effectiveness of the proposed strategy. Finally, simulation and experimental results are provided to validate the feasibility of the proposed control approach.

전력계통 제어시스템 구조에 따른 사이버 보안대책 수립 (Establishment of Cyber Security Countermeasures amenable to the Structure of Power Monitoring & Control Systems)

  • 우필성;김발호
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1577-1586
    • /
    • 2018
  • The emergence of the Smart Grid is an integrated solution for the next generation power system that combines IT technology in the power system to create optimal energy utilization and various services. However, these convergence technologies (power systems and information communications) are not only improving the related technologies but also producing various problems especially exposure to cyber risk. In particular, the intelligent power grid has security vulnerabilities through real-time information sharing among various organically linked systems, and it is more complicated than the cyber risk problem in the existing IT field and is directly connected to national disaster accidents. Therefore, in order to construct and operate a more stable smart grid, this paper analyzes the system of power system control system in Korea, and proposes a cyber security element definition and a countermeasure establishment method of power monitoring & control systems based on security standards of smart grid (No. SPS-SGSF-121-1-1).

마이크로그리드용 2기의 TMS320F28335 기반 BESS 제어기 구현 및 Hardware-in-the-Loop Simulation 시스템을 이용한 제어 성능 테스트 (Implementation of Two TMS320F28335 based BESS Controllers for Microgrid and Control Performance Test in the Hardware-in-the-Loop Simulation System)

  • 김남대;유형준;김학만
    • 전기학회논문지
    • /
    • 제63권4호
    • /
    • pp.559-564
    • /
    • 2014
  • A microgrid as a small scale power system is operated by the grid-connected mode and islanded mode. It is anticipated that the battery energy storage system (BESS) is able to be applied to the microgrid for stable power control, such as tie-line and smoothing control in the grid-connected mode and voltage and frequency control in the islanded mode. In this paper, a digital signal processor (DSP), Two BESS controllers based on TMS320F28335 of a microgrid are implemented and are tested to show control performance in the hardware-in-the loop simulation (HILS) system.

풍력발전용 권선형 유도발전기의 회전자 여자주파수를 이용한 속도와 출력제어 (A Speed and Power Control of DFIG Using the Exciting Frequency for Wind Power Generating)

  • 이우석;오철수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권7호
    • /
    • pp.349-356
    • /
    • 1999
  • Wide operating range and speed control is needed for wind power generating and a Doubly Fed Induction Generator(DFIG) has good adaptivity for that purpose. This paper deals with the speed and power control using the Grid connected DFIG in the super-synchronous speed regions, by controlling frequency and voltage fed to the rotor. Power flow of the DFIG and steady-state algebraic equations of the equivalent circuit are analyzed. For the speed control analysis, torque simulation is performed whereby the different slip between operating motor driving frequency and synchronous frequency of M-G system applied. To keep the output rating of the generator, the exciting frequency and voltage attenuation are applied.

  • PDF

PV Array 출력리플 저감을 위한 계통연계형 태양광 인버터에 관한 연구 (Study on the Grid-connected Photovoltaic Power System for Reducing Ripples of the PV Array Output)

  • 김희중;정용호;이기수;전영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1211-1212
    • /
    • 2007
  • In the PV power system, output of the PV array must contain inherent ripples due to the single-phase inverter. So, the function of maximum power point tracking to increase the output efficiency of PV system is degraded. Therefore, to overcome this problem, this paper presents a control strategy for the reducing ripples of the PV array output in grid-connected photovoltaic power system. The proposed control system consists of two loops; the maximum power point tracking loop using the perturbation and observation method is used to calculate the reference solar array terminal voltage(Vref) for reducing ripples of the PV array output and the PI control loop is used to regulate the solar array output voltage according to the Vref. The performance of proposing control strategy is analyzed by means of the PSCAD/EMTDC simulation and experiment. As a result, we may obtain the high performance of the proposed control strategy.

  • PDF

Critical Short Circuit Ratio Analysis on DFIG Wind Farm with Vector Power Control and Synchronized Control

  • Hong, Min;Xin, Huanhai;Liu, Weidong;Xu, Qian;Zheng, Taiying;Gan, Deqiang
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.320-328
    • /
    • 2016
  • The introduction of renewable energy sources into the AC grid can change and weaken the strength of the grid, which will in turn affect the stability and robustness of the doubly-fed induction generator (DFIG) wind farm. When integrated with weak grids, the DFIG wind turbine with vector power control often suffers from poor performance and robustness, while the DFIG wind turbine with synchronized control provides better stability. This paper investigates the critical short circuit ratios of DFIG wind turbine with vector power control and synchronized control, to analyze the stability boundary of the DFIG wind turbine. Frequency domain methods based on sensitivity and complementary sensitivity of transfer matrix are used to investigate the stability boundary conditions. The critical capacity of DFIG wind farm with conventional vector power control at a certain point of common coupling (PCC) is obtained and is further increased by employing synchronized control properly. The stability boundary is validated by electromagnetic transient simulation of an offshore wind farm connected to a real regional grid.

A Modified Capacitor Current Feedback Active Damping Approach for Grid Connected Converters with an LCL Filter

  • Wan, Zhiqiang;Xiong, Jian;Lei, Ji;Chen, Chen;Zhang, Kai
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1286-1294
    • /
    • 2015
  • Capacitor current feedback active damping is extensively used in grid-connected converters with an LCL filter. However, systems tends to become unstable when the digital control delay is taken into account, especially in low switching frequencies. This paper discusses this issue by deriving a discrete model with a digital control delay and by presenting the stable region of an active damping loop from high to low switching frequencies. In order to overcome the disadvantage of capacitor current feedback active damping, this paper proposes a modified approach using grid current and converter current for feedback. This can expand the stable region and provide sufficient active damping whether in high or low switching frequencies. By applying the modified approach, the active damping loop can be simplified from fourth-order into second-order, and the design of the grid current loop can be simplified. The modified approach can work well when the grid impedance varies. Both the active damping performance and the dynamic performance of the current loop are verified by simulations and experimental results.