• Title/Summary/Keyword: Grid-based Analysis

Search Result 1,127, Processing Time 0.025 seconds

Study and Design of L-C-L Filter for Single-Phase Grid-Connected PV Inverter (단상 계통연계 태양광 인버터용 L-C-L 필터 설계 및 분석)

  • Cha, Han-Ju;Vu, Trung-Kien
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.228-230
    • /
    • 2009
  • Nowadays, the LCL-filter type becomes an attractive grid interfacing for grid-connected Voltage Source Inverter (VSI). LCL-filter can render the current harmonics attenuation around the switching frequency by using smaller inductance than L-filter. This paper presents a study about the LCL-filter design for single-phase grid-connected inverter in Photovoltaic (PV) system. According to the expected current ripple, the inductances of the filter can be determined. Based on the absorbed reactive power on capacitor, the capacitance can be calculated. Due to the theoretical analysis, a LCL-filter based single phase grid connected inverter control system are simulated. The studied simulation results are given to validate the theoretical analysis.

  • PDF

Resonance Characteristics Analysis of Grid-connected Inverter Systems based on Sensitivity Theory

  • Wu, Jian;Han, Wanqin;Chen, Tao;Zhao, Jiaqi;Li, Binbin;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.746-756
    • /
    • 2018
  • Harmonic resonance exists in grid-connected inverter systems. In order to determine the network components that contribute to harmonic resonance and the composition of the resonant circuit, sensitivity theory is applied to the resonance characteristic analysis. Based on the modal analysis, the theory of sensitivity is applied to derive a formula for determining the sensitivities of each network component parameter under a resonance circumstance that reflects the participation of the network component. The solving formula is derived for both parallel harmonic resonance and series harmonic resonance. This formula is adopted to a 4-node grid-connected test system. The analysis results reveal that for a certain frequency, the participation of parallel resonance and series resonance are not the same. Finally, experimental results demonstrate that the solving formula for sensitivity is feasible for grid-connected systems.

The Digital Transformation of Power Grid under the Background of Artificial Intelligence

  • Li Liu;Zhiqi Li;Sujuan Deng;Yilei Zhao;Yuening Wang
    • Journal of Information Processing Systems
    • /
    • v.19 no.3
    • /
    • pp.302-309
    • /
    • 2023
  • Artificial intelligence (AI) plays a crucial role in the intelligent development of China's power system. It is also an important part of the digital development of the power grid. The development of AI determines whether the digital transformation of China's power system can be successfully implemented. Therefore, this paper discusses the digital transformation of the power grid based on AI technologies. The author has established a digital evaluation index system to reflect the development of the power grid in one province. Both qualitative and quantitative methods have been adopted in the analysis, which delves into the economic effectiveness, quality, and coordination of power grid development in the province in a comprehensive way. Results show that, to meet the needs of the power grid's digital transformation, the correlation coefficient between the power grid's development and the province's overall coordination has been increasing in recent years.

Performance Analysis of Distribution-based and Replication-based Model for High Performance Grid Information Service

  • Quan, Cheng-Hao;Kim, Hie-Cheol;Lee, Kang-Woo;Lee, Yong-Doo
    • Proceedings of the IEEK Conference
    • /
    • 2003.07d
    • /
    • pp.1621-1624
    • /
    • 2003
  • As the entities participating Grid become larger, performance requirement for the LDAP-based GIS(Grid Information Service) goes beyond that provided by a stand-alone single LDAP server. This entails the exploration of distributed LDAP systems. This paper presents the performance evaluation respectively for a distribution-based and a replication-based LDAP model. The analysis is based on an analytic performance model for each distributed system which is obtained by applying the M/M/1 queuing model. The performance evaluation made to these analytic models reveals that the distribution-based and the replication-based model show a significant tradeoff in their performance with respect to the system size as well as the amount of system load.

  • PDF

A Study on the Stability of Micro-Grid System (마이크로그리드 시스템의 안정도에 관한 기초 연구)

  • Son, Kwong-Myoung;Lee, Kye-Byung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.46-53
    • /
    • 2007
  • Micro-grid consists of micro-sources which adopt environmentally friendly and reliable power sources such as Fuel-Cell and Micro-Turbines with independent real and reactive power control capability for providing premium power quality. This paper deals with the basic aspect of dynamic modeling and the stability analysis of the micro-grid system. The fundamental frequency model of the micro-source inverters are considered to form a dynamic model of the micro-grid system Stability analysis is performed based on the linearized dynamic model of the micro-grid system Case study results show the parameters affecting the stability of the micro-grid.

Analysis of Phase Error Effects Due to Grid Frequency Variation of SRF-PLL Based on APF

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2016
  • This paper proposes a compensation algorithm for reducing a specific ripple component on synchronous reference frame phase locked loop (SRF-PLL) in grid-tied single-phase inverters. In general, SRF-PLL, which is based on all-pass filter to generate virtual voltage, is widely used to estimate the grid phase angle in a single-phase system. In reality, the estimated grid phase angle might be distorted because the phase difference between actual and virtual voltages is not 90 degrees. That is, the phase error is caused by the difference between cut-off frequency of all-pass filter and grid frequency under grid frequency variation. Therefore, the effects on phase angle and output current attributed to the phase error are mathematically analyzed in this paper. In addition, the proportional resonant (PR) controller is adapted to reduce the effects of phase error. The validity of the proposed algorithm is verified through several simulations and experiments.

Clustering Algorithm by Grid-based Sampling

  • Park, Hee-Chang;Ryu, Jee-Hyun
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.97-108
    • /
    • 2003
  • Cluster analysis has been widely used in many applications, such that pattern analysis or recognition, data analysis, image processing, market research on on-line or off-line and so on. Clustering can identify dense and sparse regions among data attributes or object attributes. But it requires many hours to get clusters that we want, because of clustering is more primitive, explorative and we make many data an object of cluster analysis. In this paper we propose a new method of clustering using sample based on grid. It is more fast than any traditional clustering method and maintains its accuracy. It reduces running time by using grid-based sample. And other clustering applications can be more effective by using this methods with its original methods.

  • PDF

Performance Analysis of Grid Resolution and Storm Sewage Network for Urban Flood Forecasting (지표격자해상도 및 우수관망 간소화 수준에 따른 도시홍수 예측 성능검토)

  • Sang Bo Sim;Hyung-Jun Kim
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.70-81
    • /
    • 2024
  • With heavy rainfall due to extreme weather causing increasing damage, the importance of urban flood forecasting continues to grow. To forecast urban flooding accurately and promptly, a sewer network and surface grid with appropriate detail are necessary. However, for urban areas with complex storm sewer networks and terrain structures, high-resolution grids and detailed networks can significantly prolong the analysis. Therefore, determining an appropriate level of network simplification and a suitable surface grid resolution is essential to secure the golden time for urban flood forecasting. In this study, InfoWorks ICM, a software program capable of 1D-2D coupled simulation, was used to examine urban flood forecasting performance for storm sewer networks with various levels of simplification and different surface grid resolutions. The inundation depth, inundation area, and simulation time were analyzed for each simplification level. Based on the analysis, the simulation time was reduced by up to 65% upon simplifying the storm sewer networks and by up to 96% depending on the surface grid resolution; further, the inundation area was overestimated as the grid resolution increased. This study provides insights into optimizing the simplification level and surface grid resolution for storm sewer networks to ensure efficient and accurate urban flood forecasting.

Improved grid synchronization technique based on adaptive notch filter (노치 필터 기반의 개선된 계통 동기화 기법)

  • Jung, Hoon-Young;Ji, Young-Hyok;Kim, Jae-Hyung;Lee, Su-Won;Won, Chung-Yuen;Kim, Jin-Uk;Lee, Byoung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.209-211
    • /
    • 2009
  • A digital grid synchronization technique is needed for distributed generation system to make output current sinusoidal even if the grid voltage is distorted by harmonics. In this paper, a digital grid synchronization technique based on adaptive notch filter is proposed. The analysis of proposed technique is performed through the consideration of grid synchronization technique based on PLL and FLL, and the validity of the proposed method was confirmed by simulation results.

  • PDF

A Sensitivity Analysis on Numerical Grid Size of a Three-Dimensional Hydrodynamic and Water Quality Model (EFDC) for the Saemangeum Reservoir (새만금호 3차원 수리.수질모델(EFDC)의 수치격자 민감도 분석)

  • Jeon, Ji Hye;Chung, Se Woong
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.26-37
    • /
    • 2012
  • Multi-dimensional hydrodynamic and water quality models are widely used to simulate the physical and biogeochemical processes in the surface water systems such as reservoirs and estuaries. Most of the models have adopted the Eulerian grid modeling framework, mainly because it can reasonably simulate physical dynamics and chemical species concentrations throughout the entire model domain. Determining the optimum grid cell size is important when using the Eulerian grid-based three-dimensional water quality models because the characteristics of species are assumed uniform in each of the grid cells and chemical species are represented by concentration (mass per volume). The objective of this study was to examine the effect of grid-size of a three dimensional hydrodynamic and water quality model (EFDC) on hydrodynamics and mass transport in the Saemangeum Reservoir. Three grid resolutions, respectively representing coarse (CG), medium (MG), and fine (FG) grid cell sizes, were used for a sensitivity analysis. The simulation results of numerical tracer showed that the grid resolution affects on the flow path, mass transport, and mixing zone of upstream inflow, and results in a bias of temporal and spatial distribution of the tracer. With the CG, in particular, the model overestimates diffusion in the mixing zone, and fails to identify the gradient of concentrations between the inflow and the ambient water.