• 제목/요약/키워드: Grid-Connection

검색결과 307건 처리시간 0.029초

Power Conditioning for a Small-Scale PV System with Charge-Balancing Integrated Micro-Inverter

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Seo, Jung-Won;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1318-1328
    • /
    • 2015
  • The photovoltaic (PV) power conditioning system for small-scale applications has gained significant interest in the past few decades. However, the standalone mode of operation has been rarely approached. This paper presents a two-stage multi-level micro-inverter topology that considers the different operation modes. A multi-output flyback converter provides both the DC-Link voltage balancing for the multi-level inverter side and maximum power point tracking control in grid connection mode in the PV stage. A modified H-bridge multi-level inverter topology is included for the AC output stage. The multi-level inverter lowers the total harmonic distortion and overall ratings of the power semiconductor switches. The proposed micro-inverter topology can help to decrease the size and cost of the PV system. Transient analysis and controller design of this micro-inverter have been proposed for stand-alone and grid-connected modes. Finally, the system performance was verified using a 120 W hardware prototype.

그린에너지 자립섬을 위한 계통 독립형 마이크로그리드 모니터링 시스템 설계 및 구현 (Design and Implementation of Stand-alone Microgrid Monitoring System for Green Energy Independence Island)

  • 송화정;박경욱;김응곤
    • 한국전자통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.527-532
    • /
    • 2015
  • 국내 섬지역의 전력 수급은 계통 연계가 어려워 일반적으로 디젤 발전기에 의존하고 있어 관리 비용이 매우 높다. 이러한 문제를 해결하기 위해 최근 계통 독립형 마이크로그리드 기술에 대한 연구 및 실증이 활발히 진행 중이다. 본 논문은 에너지 자립섬을 위한 계통 독립형 마이크로그리드 통합 모니터링 시스템을 제안한다. 먼저 태양광, 풍력, 디젤 발전설비, 송 배전망의 상태 및 부하, 그리고 에너지 저장 시스템의 모니터링을 위한 소프트웨어 시스템 아키텍처를 설계한 후 관리자가 쉽게 파악할 수 있는 모니터링 소프트웨어를 구현한다. 구현된 모니터링 소프트웨어는 발전설비의 상태 및 오류를 실시간으로 시각화함으로써 관리자의 신속한 의사 결정이 가능하다.

수상 태양광 발전설비 계통 연계 케이블 손상시 감전 위험에 관한 연구 (A Study on Risk of Electric Shock from Damaged Grid Connection Cable in Floating Photovoltaic System)

  • 송영상;전태현
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.14-19
    • /
    • 2014
  • Recently, many renewable energy generating businesses are ongoing progress due to the introduction of the RPS(Renewable Portfolio Standards) as well as the needs of environmentally friendly energy resources. Researches on photovoltaic system are actively being processed since the photovoltaic system is relatively easy to install and becomes commercialized in many domestic application areas. Furthermore, the floating photovoltaic system is likely to be installed more actively since the conventional photovoltaic system requires relatively large areas of land. Also, the floating photovoltaic system is more efficient than photovoltaic system installed in land due to the operation in lower temperature. However, safety problems such as electric shock could arise since the cable should be installed in the water. In this paper, the leakage current and the voltage rising are measured and analyzed for the case when the cables are damaged connecting the floating photovoltaic system to the grid.

대용량 연료전지 발전시스템용 전력변환기 개발 (Development of Power Conditioning System for High Power Fuel Cell System)

  • 강호현;이진희;백승택;정홍주;정준모;서인영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.153-156
    • /
    • 2007
  • This paper presents the design, development and performance of a power conditioning system (PCS) for application to a 250kW Molten Carbonate Fuel Cell (MCFC) generation system. A DSP controller was used to control the dc-dc and dc-ac converter operation for grid connection and power injection to the grid. The controller must also supervise the total PCS operation while communicating with the fuel cell system controller. A control method for parallel operation of dc-dc converters was proposed and verified. A 250kW prototype was successfully built and tested. Experimental performances are compared to minimum target requirements of the PCS for MCFC.

  • PDF

국내 특고압 고객에 대한 IEC 61000-3-7 기반의 플리커 방출한계 평가 및 관리 방안 연구 (Assessment and Management Method of Flicker Emission Level Based on IEC 61000-3-7 for Domestic Extra-high Voltage Customers)

  • 한수경;신훈철;박상호;김건중;조수환
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.1-7
    • /
    • 2018
  • IEC 61000-3-7 provides guidance for limiting flicker and enabling the connection of fluctuating load installations, that is, producing flicker in MV, HV and EHV power systems. In Korea, the flicker have been restricted by Japanese standard of ${\Delta}V_{10}$ method. ${\Delta}V_{10}$ was developed only for arc furnaces in 1960's. And now it is revealed that it is not suitable for application to other fluctuating load installations through many researches. $P_{st}$ which is a flicker index used in IEC 61000-3-7, indicates visual inconvenience due to voltage fluctuation across large range of frequency and can be applied to fluctuating load installations as well as arc furnaces. In this paper, we introduce how to calculate and assess flicker emission level for the individual fluctuating load installations connected in EHV system and how to manage the emission levels in the power system according to IEC 61000-3-7.

역상분 전류 주입을 적용한 3상 인버터 기반 BESS의 단독 운전 검출 방법 (Anti-islanding Detection Method for BESS Based on 3 Phase Inverter Using Negative-Sequence Current Injection)

  • 신은석;김현준;한병문
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1315-1322
    • /
    • 2015
  • This paper proposes an active islanding detection method for the BESS (Battery Energy Storage System) with 3-phase inverter which is connected to the AC grid. The proposed method adopts the DDSRF (Decoupled Double Synchronous Reference Frame) PLL (Phase Locked-Loop) so that the independent control of positive-sequence and negative-sequence current is successfully carried out using the detected phase angle information. The islanding state can be detected by sensing the variation of negative-sequence voltage at the PCC (Point of Common Connection) due to the injection of 2-3% negative-sequence current from the BESS. The proposed method provides a secure and rapid detection under the variation of negative-sequence voltage due to the sag and swell. The feasibility of proposed method was verified by computer simulations with PSCAD/EMTDC and experimental analyses with 5kW hardware prototype for the benchmark circuit of islanding detection suggested by IEEE 1547 and UL1741. The proposed method would be applicable for the secure detection of islanding state in the grid-tied Microgrid.

마이크로그리드 시스템의 계통 재연계에 관한 기초연구 (A Basic Study on the Grid Re-connection of Micro-Grid)

  • 하광호;윤창대;유현재;장성일;강용철;최정환;박용업;하경재;최영관;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.508-509
    • /
    • 2008
  • 마이크로그리드는 소형 분산 에너지원(MicroSource)으로 이루어진 분산전원망의 총칭으로 다수의 수용가들을 위하여 수요지에서 전력을 생산 및 공급하는 기술로 기본적으로 여러 수용가의 부하 및 분산발전기들이 하나의 덩어리를 형성하게 되는 새로운 개념의 배전망이다. 계통과 분리하여 운전이 가능한 마이크로그리드는 계통 연계 시 과도현상을 줄이기 위해 연계지점의 전압, 주파수, 위상을 일치하여 투입되어야 한다. 본 논문에서는 마이크로그리드 계통 재 연계 시 과도 특성을 모의한 결과를 제시하였다. 전력계통과의 분리 후 MicroSource의 전압의 크기, 주파수 및 위상을 제어하여 전력계통에 재연계하여 과도현상을 모의하는 기초연구를 진행하였다.

  • PDF

WFMS 모의를 위한 풍력발전단지 모델 구성 연구 (Study of Wind Farm Model Configuration for WFMS simulation)

  • 김현욱;정승민;황평익;유연태;송성윤;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.247-248
    • /
    • 2015
  • Wind turbines causes instabilities on the grid as their penetration increase. To mitigate harmful effects from wind turbines, transmission system operator(TSO) set up some requirements to obligate for wind generation operator for grid connection. So wind farm management system(WFMS) has important role to follow requirement from TSO, WFMS calculates available real power by considering wake effects, and dispatches real power order to each wind turbine in wind farm to optimize for decreasing load fatigue. To verify operation of WFMS, real-time simulator(RTS) is necessary. This paper deals with RTS configuration to verify WFMS operation. RTS includes wind farm model and power flow code. Normally, wind farm equivalent simple model makes wind turbines in wind farm to one wind turbine mode which cannot verify power flow in wind farm and WFMS operation. Thus, this paper makes wind farm model using simple wind turbine model with transfer function. Matlab is used for make power flow code and wind farm model to impose RTS and those model is certified by PSCAD/EMTDC.

  • PDF

배전시스템에 DC 전력원을 적용하기 위한 제어 기법 설계 (Design of a control scheme for applying DC power sources to a distribution system)

  • 황철상;김경훈;변길성;전진홍;조창희;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1056-1057
    • /
    • 2015
  • A common DC bus is a useful connection for several DC output sources such as photovoltaic (PV), fuel cells, and batteries. Operation of the common DC power system with more than two DC output sources, especially in a stand-alone mode, requires a control scheme for the stable operation of the system. In this paper, a control scheme has been developed for applying DC power sources to the distribution system. The purpose of the control scheme is to make the best use of the DC power sources. The DC power system consists of PV, two energy storage systems and a DC-AC inverter with the control scheme. A distribution system was modeled in PSCAD/EMTDC. As the results, the control scheme is applied to the DC-AC inverter and the DC-DC converter for transfer operations between the grid-connected and the stand-alone mode to keep the DC bus and the AC voltage constant. The results from the simulation demonstrate the stable operation of a grid connected DC power system.

  • PDF

마이크로 그리드에서의 풍력/디젤 복합발전 전력품질 (Power Quality of Wind/Diesel Hybrid Operation at an Micro Grid)

  • 김석우;고석환;장문석
    • 한국태양에너지학회 논문집
    • /
    • 제29권4호
    • /
    • pp.41-47
    • /
    • 2009
  • Wind/diesel hybrid operation can be one of the most effective option for electrical power production at a remote area such as Antarctica. The king Sejong station at Antarctica relies its power production on diesel engines and diesel oil is supplied every other year by ships. However, the oil transportation processes are liable to potential oil spillage caused by the floating ice around the King George island. The long-term storage of the oil at the station can also contaminate the surrounding soils. A l0kW wind turbine has been installed to save oil consumption and operated in connection with the diesel generators since 2006. The diesel engine that operated poorly during the first year of installation was replaced in 2008 to enhance power production an recent measurements indicate that both diesel power quality and the wind turbine availability have been dramatically improved by the replacement. This report discusses electrical power qualities of wind/diesel hybrid system operating at an isolated micro gird located in the king Sejong station. Our experience reveals that the similar technologies can be applied to domestic islands, for example, in the south sea.