• Title/Summary/Keyword: Grid-Cell

Search Result 625, Processing Time 0.028 seconds

Suggestions on the Selection Method of Priority Monitoring Sites for Hazardous Air Pollutants in Megacities (유해대기오염물질 모니터링을 위한 대도시 우선순위 측정지점 선정기법 제안)

  • Kwon, Hye-Ok;Kim, Seong-Joon;Kim, Yong Pyo;Kim, Sang-Kyun;Hong, Ji-Hyung;Choi, Sung-Deuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.544-553
    • /
    • 2017
  • There is an overall guideline of the installation of air quality monitoring stations in Korea, but specified steps for the selection of monitoring sites for hazardous air pollutants(HAPs) are not provided. In this study, we proposed a systematic method for the selection of monitoring sites for HAPs using geographic information system (GIS). As a case study, the Seoul metropolitan area (Seoul, Incheon, and Gyeonggi Province) was chosen, and 15 factors including population, vehicle registration, and emission data were compiled for each grid cell ($7km{\times}7km$). The number of factors above the top 30% of individual data for each grid cell was used to select priority monitoring sites for HAPs. In addition, several background sites were added for data comparison and source identification. Three scenarios were suggested: Scenario 1 with 7 sites, Scenario 2 with 17 sites, and Scenario 3 with 30 sites. This proposal is not the final result for an intensive monitoring program, but it is an example of method development for selecting appropriate sampling sites. These results can be applied not only to HAPs monitoring in megacities but also to the national HAPs monitoring network.

Effect of Change of Numerical Parameters on Outflow Characteristics in the Linear Muskingum-Cunge Method (선형 Muskingum-Cunge 법에서의 수치적 인자의 변화가 유출특성에 미치는 영향)

  • 김진수
    • Water for future
    • /
    • v.29 no.5
    • /
    • pp.139-150
    • /
    • 1996
  • This paper presents the effect of numerical parameters, such as grid size and grid ratio, on the outflow hydrograph of a unit-width plane in the linear Muskingum-Cunge method. The numerical results depend on Courant number C and cell Reynolds number D, two physically and numerically meaningful parameters. As C approache 1 and D increases, the numerical dispersion-relating oscillations are difficult to occur. The numerical oscillations occur in the front of a propagating wave for C < 1, while smaller oscillations occur behind the wave for C > 1 due to the numerical diffusion effect. For a plane with a small value of characteristic reach length L (e.g., a steep plane), the numerical solution of the Muskingum-Cunge method is similar to that of the kinematic wave method, which shows no wave attenuation. However, for a plane with a large value of L (e.g., a mild plane), the Muskingum-Cunge method leads to the diffusion waves which are essentially independent of the Courant number. Accordingly, the Muskingum-Cunge method will be suited for the routing of the catchment with relatively mild slopes.

  • PDF

Runoff Analysis using ModClark Model (ModClark 모형을 이용한 유출 해석)

  • Ahn, Sang-Jin;Yoon, Seok-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.3 s.152
    • /
    • pp.245-257
    • /
    • 2005
  • The purpose of the present study is examining the changes of runoff characteristics and extracting hydrologic parameters by applying ModClark model on grid divided watershed. Bocheong stream basin in Geum River system, one of the representative watersheds of IHP projects, is selected. Hydrology-based topographical informations are calculated using GIS data in the HEC-GeoHMS V1.1 extension in Arcview 3.2. The ModClark model requires precipitation data in a gridded format. The gridded data must be recorded in the HEC Data Storage System file format. Therefore, kriging method was used to interpolate the point values to create a grid that gives each cell over the entire watershed a precipitation value. Hec-DSSVue program was used to create DSS file for the rain gage data. The completed HEC-HMS model was calibrated for use in simulating three measured storm events and cell size of 10000m, 5000m, 2000m, 1000m was chosen for the application. As the result of applying distributed rainfall-runoff model to analyze relatively good agreement for peak discharge, runoff volume and peak time.

Effect of Design Parameters on the Efficiency of the Solar Cells Fabricated Using SOI Structure (SOI 구조 이용한 결정질 규소 태양전지의 최적설계)

  • Lee, Gang-Min;Kim, Yeong-Gwan
    • Korean Journal of Materials Research
    • /
    • v.9 no.9
    • /
    • pp.890-895
    • /
    • 1999
  • The recent important issue in solar cell fabrication is to adopt thin film silicon solar cells on cheap substrates. However, thin cells demand new grid design concept that all the contacts(to the emitter and base) be located on the front surface. Hence, the aim of the investigation presented in this paper was to determine the potential and the basic limitation of the design. With this concept, an interdigitated front grid structure was realized and cells were fabricated through a set of photolithography processes. Confirmed efficiencies of up to 11.5% were achieved on bonded SOI wafers with a cell thickness of 50$\mu\textrm{m}$ in the case of finger spacing more than $\mu\textrm{m}$ and a base width of 35$\mu\textrm{m}$. It was also shown from the results that the design rules for optimizing the base fraction and reducing the shadowing fraction are noted as an important technique to realize high-efficiency thin silicon solar cells.

  • PDF

A Study on the Groundwater Flow in Fractured-Porous Media by Flow Resistance Theory (단열-다공암반에서 유동저항 이론을 이용한 지하수 유동 평가에 관한 연구)

  • Han Ji-Woong;Hwang Yong-Soo;Kang Chul-Hyung
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.231-238
    • /
    • 2005
  • On the basis of flow resistance theory the conceptual model and related mathematical descriptions is proposed for resistance modeling of groundwater flow in CPM(continuum Porous medium), DFN(discrete fracture network) and fractured-porous medium. The proposed model is developed on the basis of finite volume method assuming steady-state, constant density groundwater flow. The basic approach of the method is to evaluate inter-block flow resistance values for a staggered grid arrangement, i.e. fluxes are stored at cell walls and scalars at cell centers. The balance of forces, i.e. the Darcy law, is utilized for each control volume centered around the point where the velocity component is stored. The transmissivity (or permeability) at the interface is assumed to be the harmonic average of neighboring blocks. Flow resistance theory was utilized to relate the fluxes between the grid blocks with residual pressures. The flow within porous medium is described by three dimensional equations and that within an individual fracture is described by a two dimensional equivalent of the flow equations for a porous medium. Newly proposed models would contribute to develop flow simulation techniques with various matrix characteristics.

  • PDF

Maximum Efficiency Point Tracking Algorithm Using Oxygen Access Ratio Control for Fuel Cell Systems

  • Jang, Min-Ho;Lee, Jae-Moon;Kim, Jong-Hoon;Park, Jong-Hu;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.194-201
    • /
    • 2011
  • The air flow supplied to a fuel cell system is one of the most significant factors in determining fuel efficiency. The conventional method of controlling the air flow is to fix the oxygen supply at an estimated constant rate for optimal efficiency. However, the actual optimal point can deviated from the pre-set value due to temperature, load conditions and so on. In this paper, the maximum efficiency point tracking (MEPT) algorithm is proposed for finding the optimal air supply rate in real time to maximize the net-power generation of fuel cell systems. The fixed step MEPT algorithm has slow dynamics, thus it affects the overall efficiency. As a result, the variable step MEPT algorithm is proposed to compensate for this problem instead of a fixed one. The complete small signal model of a PEM Fuel cell system is developed to perform a stability analysis and to present a design guideline. For a design example, a 1kW PEM fuel cell system with a DSP 56F807 (Motorola Inc) was built and tested using the proposed MEPT algorithm. This control algorithm is very effective for a soft current change load like a grid connected system or a hybrid electric vehicle system with a secondary energy source.

Study on the Development of Efficient Vitrification of Human Blastocysts (인간포배기 배아의 효과적인 유리화 동결법의 개발을 위한 연구)

  • Lee, Sang-Min;Lee, Ju-Hee;Lee, Sang-Won;Lee, Seoung-Min;Yoon, San-Hyun;Lim, Jin-Ho;Park, Huem-Dai;Lee, Seong-Goo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.30 no.3
    • /
    • pp.241-248
    • /
    • 2003
  • Objective: The purpose of this study was to evaluate the survival rate of vitrified blastocyst according to the freezing vessels, equilibration time in cryoprotectant and artificial dehydration method. Methods: Human blastocysts were vitrified after loading onto the plastic straw, open-pulled straw (OPS), electron microscopy grid (EM grid) for 1.5 min or 3 min. They also were directly plunged into LN2 within 30sec. For artificial shrinkage of blastocysts, 36 gauge fine needle was pushed at the cellular junction of the trophectoderm into the blstocoele cavity until it shrank without damage of inner cell mass. Results: The survival rate of vitrified blastocysts on plastic straw, OPS, EM grid as freezing vessels were 26.7, 13.0 and 60.5%, respectively. The survival rate of EM grid was significantly higher than that of plastic straw and OPS (p<0.05). For 1.5 min equilibrium, the survival rates of early blastocyst (EB), middle blastocyst (MB) and late blastocyst (LB) were 64.4, 81.0, and 20.0% respectively. For 3 min equilibrium, the survival rates of EB, MB, and LB were 69.9, 50.0 and 57.5% respectively. The survival rates of EB and MB were significantly higher than that of LB in 1.5 min equilibrium group (p<0.05), however, the significance was not observed in 3 min equilibrium groups. In cytoplasmic shrinkage before vitrification, the survival rates of EB, MB and LB were 92.9, 100 and 75.9% respectively. The survival rate of MB was significantly higher than that of LB (p<0.05). The survival rates of vitrified blastocysts by artificial dehydration and slow-frozen blastocysts were not significantly different as 88.9 and 66.7%, respectively. Conclusion: This study showed that the vitrification of human blastocysts using EM grid and artificial dehydration is an effective method. Therefore, these methods would be an useful techniques for blastocyst cryopreservation.

Developmental Capacity of Bovine Follicular Oocytes after Ultra-Rapid Freezing by Electron Microscope Grid - I. Cryopreservation of Bovine Immature Oocytes (Electron Microscopic Grid를 이용한 초급속동결이 소 난포란의 발달능에 미치는 영향 - I. 소 미성숙난자의 동결에 관한 연구)

  • Kim, E.Y.;Kim, N.H.;Yi, B.K.;Yoon, S.H.;Park, S.P.;Chung, K.S.;Lim, J.H.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.25 no.1
    • /
    • pp.71-76
    • /
    • 1998
  • This study was carried out to examine whether the developmental capacity of bovine immature oocytes frozen ultra-rapidly using electron microscope (EM) grids and EFS30 can be obtained. As freezing solution, we used EFS30 which consisted of 30% ethylene glycol, 0.5 M sucrose, 18% ficoll and 10% FBS added in D-PBS. As criterior of oocyte viability, the rates of maturation, fertilization and embryonic development were determined. The results obtained in this experiment were summarized as follows: When ultra-rapidly frozen immature oocytes were thawed, 43.2% of them were survived. The rates of maturation (84.1%) and normal 2 pronuclei formation (57.5%) of frozen immature oocytes were not significantly different when compared to those of control (92.5, 65.0%). In addition, the rates of $\geq2$-cell (65.0%) and blastocyst formation (30.8%) of freezing group were not significantly different when compared to those of control (73.7, 35.7%). These results demonstrate that developmental capacity of frozen-thawed bovine immature oocytes can be successfully obtained when survived from the ultra-rapid freezing method using EM grid and EFS30.

  • PDF

Power Balancing Strategy in the Microgrid During Transient (마이크로그리드 과도상태 시 전력 수급 균형 전략)

  • Seo, Jae-Jin;Lee, Hak-Ju;Jung, Won-Wook;Won, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.707-714
    • /
    • 2010
  • When problems such as line fault, breakdown of a substation or a generator, etc. arise on the grid, the Microgrid is designed to be separated or isolated from the grid. Most existing DGs(Distributed Generators) in distribution system use rotating machine. However, new DGs such as micro gas turbine, fuel cell, photo voltaic, wind turbine, etc. will be interfaced with the Microgrid through an inverter. So the Microgrid may have very lower inertia than the conventional distribution system. By the way, the rate of change of frequency depends on the inertia of the power system. Moreover, frequency has a strong coupling with active power in power system. Because the frequency of the Microgrid may change rapidly and largely during transient, appropriate and fast control strategy is needed for stable operation of the Microgrid. Therefore, this paper presents a power balancing strategy in Microgrid during transient. Despite of strong power or frequency excursions, power balancing in the Microgrid can be maintained.

Convergence and Stability Analysis of LU Scheme on Unstructured Meshes: Part II - Navier-Stokes Equations (비정렬 격자계에서 LU implicit scheme의 수렴성 및 안정성 해석: Part II - Navier-Stokes 방정식)

  • Kim, Joo-Sung;Kwon, Oh-Joon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.8
    • /
    • pp.1-11
    • /
    • 2004
  • A comprehensive study has been made for the investigation of the convergence and stability characteristics of the LU scheme for solving the Navier-Stokes equations on unstructured meshes. For this purpose the characteristics of the LU scheme was initially studied for a scalar model equation. Then the analysis was extended to the Navier-Stokes equations. It was shown that the LU scheme has an inherent stiffness in the streamwise direction. This stiffness increases when the grid aspect ratio becomes high and the cell Reynolds number becomes small. It was also shown that the stiffness related to the grid aspect ratio can be effectively eliminated by performing proper subiteration. The results were validated for a flat-plate turbulent flow.