• Title/Summary/Keyword: Grid effects

Search Result 627, Processing Time 0.028 seconds

Analysis of Phase Error Effects Due to Grid Frequency Variation of SRF-PLL Based on APF

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2016
  • This paper proposes a compensation algorithm for reducing a specific ripple component on synchronous reference frame phase locked loop (SRF-PLL) in grid-tied single-phase inverters. In general, SRF-PLL, which is based on all-pass filter to generate virtual voltage, is widely used to estimate the grid phase angle in a single-phase system. In reality, the estimated grid phase angle might be distorted because the phase difference between actual and virtual voltages is not 90 degrees. That is, the phase error is caused by the difference between cut-off frequency of all-pass filter and grid frequency under grid frequency variation. Therefore, the effects on phase angle and output current attributed to the phase error are mathematically analyzed in this paper. In addition, the proportional resonant (PR) controller is adapted to reduce the effects of phase error. The validity of the proposed algorithm is verified through several simulations and experiments.

Experimental Study on Aerodynamic Characteristics for Missile Configuration With Grid Fins in Subsonic Flow (아음속 유동에서 그리드핀 유도무기의 공력특성 분석을 위한 실험적연구)

  • Lee, Yeongbin;Lee, Changgu;Lee, Jonggeon;Kim, Sungcheol;Kim, Namgyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.9
    • /
    • pp.721-727
    • /
    • 2021
  • In this paper, aerodynamic characteristics of missile configuration with various grid fins in subsonic flow. To investigate the effects of grid fin shape, four types of experimental models were used. In addition, to examine aerodynamic characteristics of missile configurations with various grid fins according to effects of Reynolds numbers and configurations of grid fins, 6-components aerodynamic forces and moments were measured by internal balance in wind tunnel test.

The Effects of Penetration of the Electric Vehicles on the Electric Power Grid in the Jeju Island (제주도에서 전기자동차 보급이 전력계통에 미치는 영향)

  • Oh, Seong-Bo;Lee, Gae-Myoung;Hwang, Choong-Gu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • The Jeju Special Self-Government Provincial Government has made the plan penetrating gradually electric vehicles(EVs) in the Jeju Special Self-Government Province(Jejudo). However the effects of EVs penetration on the electrical grid of the Jejudo is not reported. In this paper the yearly electric energy consumed by the EVs was calculated and the effects of the EV penetration on the peak power of the grid were analyzed in the Jejudo for the future 10 years, and we hope that our study results will help the governors realize the EVs penetration plan in the Jejudo. The calculation results show that the rate of the electric energy used by the EVs will become to 2.9% at its maximum at the 2017 year when the penetration rate of EVs in passenger cars becomes 10%, and the rate of the electric energy consumed by the EVs will become to 9.4% at its maximum at the 2020 year when the penetration rate of EVs in passenger cars becomes 30%. The concepts of smart-charging capacity and 100%-valley-filling charging capacity of the grid were defined and calculated for the Jeju Grid, and the grid was analyzed to have the sufficient EV charging capacity until the 2022 year.

Effects of Grid Size on Noise Prediction Results of Road Traffic Noise Map (소음지도 격자크기가 도로교통 소음도 예측 결과에 미치는 영향)

  • Kim, Ji-Yoon;Park, In-Sun;Park, Chan-Youn;Park, Sang-Kyu;Ryu, Bong-Jo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.867-871
    • /
    • 2007
  • Noise map is very efficient tool to evaluate the road traffic noise. However, calculation time and accuracy of noise map heavily depend on the grid size of noise map. In this study, effects of grid size on the prediction results of road traffic noise map have been investigated in detail for urban and rural areas, respectively, and efficient grid size for the noise map has been proposed.

  • PDF

Effects of Grid Size on Noise Prediction Results of Road Traffic Noise Map (소음지도 격자크기가 도로교통 소음도 예측결과에 미치는 영향)

  • Kim, Ji-Yoon;Park, In-Sun;Park, Chan-Youn;Park, Sang-Kyu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.2
    • /
    • pp.199-204
    • /
    • 2010
  • Noise map is very efficient tool to evaluate the road traffic noise. However, calculation time and accuracy of noise map heavily depend on the grid size of noise map. In this study, effects of grid size on the prediction results of road traffic noise map have been investigated in detail for urban and rural areas, respectively, and efficient grid size for the noise map has been proposed.

A Study on Grid Effect and Applicability of Composite Reinforcement (그리드효과 및 복합보강재의 적용성에 관한 연구)

  • 김홍택;이형규;김승욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.11c
    • /
    • pp.95-104
    • /
    • 1999
  • In this study, laboratory pull-out tests and finite element modeling are carried out focused on the grid effects of geogrid and the analyses of friction characteristics associated with interaction behaviors of the composite reinforcement composed of geogrid with a superior function in tensile resistance and geotextile with sufficient drainage effects. In addition, drainage effects of the geotextile below geogrid are examined based on the analysis of finite difference numerical modeling. From the present investigation, it is concluded that the geosynthetic composite reinforcement in the weathered granite backfills may possibly be used to achieve effects on both a reduction of deformations and an increase of the tensile resistance, together with drainage effects due to the geotextile.

  • PDF

Modification of QUICK Scheme for Unstructured Grid Finite Volume Method (비정렬 유한체적법을 위한 QUICK법의 수정)

  • Kang, Dong Jin;Bae, Sang Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.9
    • /
    • pp.1148-1156
    • /
    • 2000
  • The QUICK scheme for convection terms is modified for unstructured finite volume method by using linear reconstruction technique and validated through the computation of two well defined laminar flows. It uses two upstream grid points and one downstream grid point in approximating the convection terms. The most upstream grid point is generated by considering both the direction of flow and local grid line. Its value is calculated from surrounding grid points by using a linear construction method. Numerical error by the modified QUICK scheme is shown to decrease about 2.5 times faster than first order upwind scheme as grid size decreases. Computations are also carried out to see effects of the skewness and irregularity of grid on numerical solution. All numerical solutions show that the modified QUICK scheme is insensitive to both the skewness and irregularity of grid in terms of the accuracy of solution.

An Analysis on Power Demand Reduction Effects of Demand Response Systems in the Smart Grid Environment in Korea

  • Won, Jong-Ryul;Song, Kyung-Bin
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1296-1304
    • /
    • 2013
  • This study performed an analysis on power demand reduction effects exhibited by demand response programs, which are advanced from traditional demand-side management programs, in the smart grid environment. The target demand response systems for the analysis included incentive-based load control systems (2 month-ahead demand control system, 1~5 days ahead demand control system, and demand bidding system), which are currently implemented in Korea, and price-based demand response systems (mainly critical peak pricing system or real-time pricing system, currently not implemented, but representative demand response systems). Firstly, the status of the above systems at home and abroad was briefly examined. Next, energy saving effects and peak demand reduction effects of implementing the critical peak or real-time pricing systems, which are price-based demand response systems, and the existing incentive-based load control systems were estimated.

VERIFICATION OF 2D INJECTION FLOWS WITH GCI AND NEAR-WALL GRID LINE SPACINGS (GCI와 벽면격자거리를 고려한 2차원 분사유동의 검증)

  • Won Su-Hee;Jeung In-Seuck;Choi Jeong-Yeol
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.287-292
    • /
    • 2005
  • The flowfields generated by gaseous slot injection into a supersonic flow at a Mach number of 3.75 and a Reynolds number of $2.07{\times}10^7$ are simulated numerically. Fine-scale turbulence effects are represented by a two-equation(k-w SST model) closure model which includes $y^+$ effects on the turbulence model. Grid convergence index(GCI) is also considered to provide a measure of uncertainty of the grid convergence. Comparison is made with experimental data and other turbulence model in term of surface static pressure distributions, the length of the upstream separation region, and the penetration height. Results indicate that the k-w SST model correctly predicts mean surface pressure distribution and upstream separation length. However, it is also observed that the numerical simulation over predicts the pressure spike and penetration height compared with experimental data. All these results are taken within $1\%$ error band of grid convergence.

  • PDF

Grid Connected Inverter of ESS for Seamless mode Transition (분산 발전 시스템에서 계통연계 인버터의 매끄러운 모드 전환)

  • Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.364-372
    • /
    • 2016
  • In this paper, a voltage controller for the seamless transition of a grid-connected inverter for ESS is proposed. The single-phase inverter is operated as a current controller when the grid is connected and as a voltage controller in the stand-alone mode when the grid is disconnected. Generally, in the case of grid recovery, the overcurrent may flow into the system because of the mismatch phase between the inverter output and grid voltages. The proposed controller resolves the overcurrent problem through phase delay problems with initial value feed-forward control of the integrator when the grid voltage is restored. The effects of the control method are simulated through PSIM, and the usefulness of the control method is verified through experiments.