• 제목/요약/키워드: Grid connected

검색결과 1,226건 처리시간 0.028초

A Takagi-Sugeno fuzzy power-distribution method for a prototypical advanced reactor considering pump degradation

  • Yuan, Yue;Coble, Jamie
    • Nuclear Engineering and Technology
    • /
    • 제49권5호
    • /
    • pp.905-913
    • /
    • 2017
  • Advanced reactor designs often feature longer operating cycles between refueling and new concepts of operation beyond traditional baseload electricity production. Owing to this increased complexity, traditional proportional-integral control may not be sufficient across all potential operating regimes. The prototypical advanced reactor (PAR) design features two independent reactor modules, each connected to a single dedicated steam generator that feeds a common balance of plant for electricity generation and process heat applications. In the current research, the PAR is expected to operate in a load-following manner to produce electricity to meet grid demand over a 24-hour period. Over the operational lifetime of the PAR system, primary and intermediate sodium pumps are expected to degrade in performance. The independent operation of the two reactor modules in the PAR may allow the system to continue operating under degraded pump performance by shifting the power production between reactor modules in order to meet overall load demands. This paper proposes a Takagi-Sugeno (T-S) fuzzy logic-based power distribution system. Two T-S fuzzy power distribution controllers have been designed and tested. Simulation shows that the devised T-S fuzzy controllers provide improved performance over traditional controls during daily load-following operation under different levels of pump degradation.

An Analysis on Seoullo 7017 in Terms of Spatial Configuration and Pedestrian Movement in Comparison with the High-line Project

  • Choi, Junho;Choi, Jaepil
    • Architectural research
    • /
    • 제21권2호
    • /
    • pp.31-39
    • /
    • 2019
  • Inspired by the success of the High-line project in New York, The Seoul Metropolitan Government launched a project to convert an overpass near Seoul station into a pedestrian park. Seoullo 7017 went through instant success after its opening in May 2017; however, there is a continuous controversy over its long-term impact as shown in the exemplary cases like the High-line project. This study aims for quantitative investigation through the comparative analysis between Seoullo 7017 and the High-Line in the perspectives of spatial configuration. Space Syntax was chosen as the analysis method for this research. Integration (3) in Space Syntax is known to have a high correlation with pedestrian volume; thus, by using this method, spatial structure was analyzed by comparing the statistically verified results of changes in the spatial structure of the Highline with those in Seoul. The results indicated that the influence of Seoullo 7017 was less than that of the High-line in terms of spatial configuration. The reason for this difference is spatial configuration between Manhattan and Seoul. The High-line is located in Manhattan which has an urban grid structure, whereas Seoul has non-geometric urban structure, the neighborhood unit in Korea. Also the center of the overpass isn't connected well with its surroundings.

A Study on Determining an Appropriate Power Trading Contracts to Promote Renewable Energy Systems

  • Choi, Yeon-Ju;Kim, Sung-Yul
    • International Journal of Precision Engineering and Manufacturing-Green Technology
    • /
    • 제5권5호
    • /
    • pp.623-630
    • /
    • 2018
  • The renewable energy systems have been in the spotlight as an alternative for environmental issues. Therefore, the governmental policies are being implemented to spread of promote power generation system using renewable energy in various countries around the world. In addition, Korea has also developed a policy called the power trading contract which can profit from electricity produced from renewable power generation system through Korea Electric Power Corporation (KEPCO) and Korea Power Exchange (KPX). As a result, the power trading contracts can trade power after self-consuming in-house by using small-scale renewable power system for residential customers as well as electricity retailers. The power trading contracts applicable as a small-scale power system have a 'Net metering (NM)' and a 'Power Purchase Agreement (PPA)', and these two types of power trading contracts trade surplus power, but payment method of each power trading is different. The microgrid proposed in this paper is based on grid connected microgrid using Photovoltaic (PV) system and Energy Storage System (ESS), that supplied power to residential demand, we evaluate the operation cost of microgrid by power demand in each power trading contracts and propose the appropriate power trading contracts according to electricity demand.

최적 일체형 태양광 발전용 전력변환장치 PCS 특성에 관한 연구 (A Study on the Characteristics of PCS Using a Solar Cells Generation of Optimal Integrated)

  • 황락훈
    • 전기전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.1003-1014
    • /
    • 2019
  • 본 논문에서는 PV 시스템에서 사용되는 회로들을 쉽게 해석할 수 있도록 모델링하였다. 시뮬레이션 툴은 직관적인 전기회로 시뮬레이션이 가능한 PSPICE를 이용하였다. 모델링한 라이브러리를 이용하여 태양전지의 사용에서 간과하기 쉬운 온도와 공간방사의 영향에 대해서도 시뮬레이션을 수행하였다. 이와 더불어 태양광 발전 시스템의 완전한 동작을 위해 DC-DC 벅-부스트 컨버터와 MPPT 제어 시스템에 대한 완전한 동작 시스템에 대해 모델링하고 시뮬레이션을 수행하여 양호한 동작을 확인할 수 있었다. 또한 시뮬레이션의 동작을 입증하기 위하여 시뮬레이션에서와 동일한 조건의 실제 시스템을 구성하여 실험을 수행 하였으며 실험의 결과와 시뮬레이션의 결과가 동일한 동작을 수행하는 것을 확인할 수 있었다. 또한, 단상 3[kW] 계통연계형 태양광 전력변환기를 제안하였다.

Seamless Mode Transfer of Utility Interactive Inverters Based on Indirect Current Control

  • Lim, Kyungbae;Song, Injong;Choi, Jaeho;Yoo, Hyeong-Jun;Kim, Hak-Man
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.254-264
    • /
    • 2019
  • This paper proposes an indirect current control technique based on a proportional resonant (PR) approach for the seamless mode transfer of utility interactive inverters. Direct-current and voltage hybrid control methods have been used for inverter control under grid-connected and islanded modes. A large bandwidth can be selected due to the structure of single-loop control. However, this results in poor dynamic transients due to sudden changes of the controller during mode changes. Therefore, inverter control based on indirect current is proposed to improve the dynamic transients by consistently controlling the output voltage under all of the operation modes. A PR-based indirect current control topology is used in this study to maintain the load voltage quality under all of the modes. The design processes of the PR-based triple loop are analyzed in detail while considering the system stability and dynamic transients. The mode transfer techniques are described in detail for both sudden unintentional islanding and islanded mode voltage quality improvements. In addition, they are described using the proposed indirect control structure. The proposed method is verified by the PSiM simulations and laboratory-scale VDER-HILS experiments.

Design of Micro Water Supply System Using Solar Energy

  • Sharma, Ekisha;Khatiwada, Nawa Raj;Ghimire, Anish
    • 적정기술학회지
    • /
    • 제5권1호
    • /
    • pp.8-17
    • /
    • 2019
  • Solar pumps, for water lift systems, is becoming popular in rural areas for supplying drinking water in dry seasons when its need is elevated. The development in technology has also made solar pumps readily available and cheap which has increased its demands. So, for scattered settlements having a limited budget for operation and maintenance costs, solar pump is preferred over grid connected electrical pumping systems. This primary objective of the study was to design a solar photovoltaic pumping drinking water supply system for a small health post which is about 45 km east from Kathmandu, the capital city of Nepal. The study also compared and verified the final design with the system's existing design prepared by a development agency. The water source for this study was a confined aquifer 115m below the surface. The water demand was calculated to be 11m3 per day. A 1500 kPa submersible pump attached to a motor was selected and installed. Along with that twelve solar panels, reservoir, transmission main and distribution main was designed. The outcomes conclude solar photovoltaic pumping water supply systems to be cost-effective with an estimated cost of only USD 0.84 million per MLD. Solar pumps require low maintenance and operation costs and its repairs can quickly be done by the local people. The study also shows that solar technology produces no sound, needs no fuel making it environmentally friendly.

Optimal installation of electric vehicle charging stations connected with rooftop photovoltaic (PV) systems: a case study

  • Heo, Jae;Chang, Soowon
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.937-944
    • /
    • 2022
  • Electric vehicles (EVs) have been growing to reduce energy consumption and greenhouse gas (GHG) emissions in the transportation sector. The increasing number of EVs requires adequate recharging infrastructure, and at the same time, adopts low- or zero-emission electricity production because the GHG emissions are highly dependent on primary sources of electricity production. Although previous research has studied solar photovoltaic (PV) -integrated EV charging stations, it is challenging to optimize spatial areas between where the charging stations are required and where the renewable energy sources (i.e., solar photovoltaic (PV)) are accessible. Therefore, the primary objective of this research is to support decisions of siting EV charging stations using a spatial data clustering method integrated with Geographic Information System (GIS). This research explores spatial relationships of PV power outputs (i.e., supply) and traffic flow (i.e., demand) and tests a community in the state of Indiana, USA for optimal sitting of EV charging stations. Under the assumption that EV charging stations should be placed where the potential electricity production and traffic flow are high to match supply and demand, this research identified three areas for installing EV charging stations powered by rooftop PV in the study area. The proposed strategies will drive the transition of existing energy infrastructure into decentralized power systems. This research will ultimately contribute to enhancing economic efficiency and environmental sustainability by enabling significant reductions in electricity distribution loss and GHG emissions driven by transportation energy.

  • PDF

Hybrid High-efficiency Synchronous Converter using Si IGBT and SiC MOSFET

  • Il Yang;Woo-Joon Kim;Tuan-Vu Le;Seong-Mi Park;Sung-Jun Park;Ancheng Liu
    • 한국산업융합학회 논문집
    • /
    • 제26권6_1호
    • /
    • pp.967-976
    • /
    • 2023
  • Currently, with the thriving development in the field of solar energy, the widespread adoption of solar grid-connected power conversion systems is rapidly expanding. As the market continues to grow, the efficiency of solar power conversion systems is steadily increasing, while prices are rapidly decreasing. Photovoltaic panels often produce low output voltages, and Boost converters are commonly employed to elevate and stabilize these voltages. They are also utilized for implementing Maximum Power Point Tracking (MPPT), ensuring the full utilization of solar power generation. Recently, synchronous control techniques have been introduced, using controllable switching devices like Si IGBT or SiC MOSFET to replace the diodes in the original circuits. However, this has raised concerns related to costs. This paper offers a compromise solution, considering both the performance and economic factors of the converter. It proposes a hybrid high-efficiency synchronous converter structure that combines Si IGBT and SiC MOSFET. Additionally, the proposed topology has been practically implemented and tested, with results confirming its feasibility and cost-effectiveness.

Securing the IoT Frontier: Exploring the Limitation and Future Directions in Cybersecurity

  • Moustafa Abdelrahman Mahmoud Ahmed;Nur Arzilawati Md Yunus
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.1-9
    • /
    • 2024
  • As the Internet of Things (IoT) continues to permeate every facet of modern life, the imperative to secure this vast and dynamic frontier becomes increasingly paramount. This presents a comprehensive exploration of the challenges and opportunities inherent in safeguarding the interconnected web of IoT devices. The research critically examines the limitations of current cybersecurity measures through an extensive review of diverse topics, including IoT network performance, smart grid security, and the escalating cyber threats against critical infrastructures. A meticulous analysis of research findings underscores the need for enhanced infrastructure and ongoing research to fortify the cybersecurity mechanisms surrounding IoT objects. We underline the imperative of relentless research efforts to parry the advancing threats and leverage the promise of nascent technologies. Our findings affirm the pivotal influence of robust cybersecurity measures in crafting a resiliently connected ecosystem. The paper underscores the importance of ongoing research to address evolving threats and harness the potential of emerging technologies, reaffirming the central role of cybersecurity in shaping a secure interconnected world. In conclusion, the study emphasizes the dynamic and ever-evolving nature of cybersecurity on the IoT frontier. It unveils a complex landscape of challenges, ranging from network performance intricacies to the security concerns of critical infrastructures.

그리드 기반 키 선분배 방식을 사용하는 공장 설비 모니터링 시스템 설계 및 구현 (Design and Implementation of Factory Equipment Monitoring System using Grid-based Key Pre-Distribution)

  • 조양희;박재표;양승민
    • 한국산학기술학회논문지
    • /
    • 제17권11호
    • /
    • pp.51-56
    • /
    • 2016
  • 본 논문에서는 아두이노 기반의 공장 설비 모니터링 시스템을 제안한다. 제안하는 시스템은 아두이노 플랫폼을 기반으로 하며 온도, 습도 그리고 조도를 측정하는 환경 센서와 압력 센서를 이용하여 공장의 환경 및 설비의 상태를 모니터링 한다. 모니터링 데이터는 RF(Radio Frequency) 트랜시버를 통해 서버에 연결되어 있는 지그비 코디네이터로 전송된다. 호스트 서버에 저장된 환경 센서와 압력센서의 데이터를 이용하여 공장의 환경과 설비의 압력 상태를 확인하고 설정된 알람 상태에 도달하면 관리자에게 보고하도록 설계하였다. 그리드 기반 키 선분배 방식을 사용하여 센서 노드를 인증하고 데이터 키를 동적으로 생성하여 모니터링 정보를 보호한다. 추가적인 배선 작업이 필요 없는 지그비 무선 센서 네트워크를 적용하여 공장설비 모니터링 시스템을 실제 구현함으로서 효율적인 공장의 작업 환경 모니터링이 가능하다. 또한 불량이 발생한 경우, 작업 환경을 역으로 추적하여 불량 원인 분석에 활용할 수 있다. 아두이노 플랫폼과 확장 보드를 이용하여 평탄도나 진동 같은 센서를 추가하거나 확장 보드에 연결된 포트로 제어 하는 등의 기능 확장이 용이하다.