• Title/Summary/Keyword: Grid Unit

Search Result 282, Processing Time 0.04 seconds

A Study on Influence Line of Curved I-Girder Grid Bridge with Constant Cross Section (등단면 I-형 곡선 격자형교의 영향선에 관한 연구)

  • Chang, Byung Soon;Ryoo, Eun Yeol;Joo, Jae Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.501-513
    • /
    • 1997
  • The general behavior of curved girder including the warping effects is formulated by series of differential equations postulated by Vlasov. In order to determine the maximum shear force, the maximum bending moment, the maximum pure torsion, the maximum warping torsion, and the maximum bimoment for the curved girder grid bridges, it is important to find the location of live load applied to the curved girder grid bridges, so that the influence line can be estimated. In this paper, the influence line of shear force, bending moment, pure torsion, warping torsion, and bimoment due to unit vertical load and unit torsional moment for curved I-girder grid bridges are obtained by using the finite difference method.

  • PDF

Feasibility Study for the Location of Air Quality Monitoring Network in Daegu Area (대구지역 대기오염자동측정망 위치의 타당성 분석)

  • Choi, Sung-Woo;Lee, Jung-Beom
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.81-91
    • /
    • 2011
  • Air quality monitoring networks are very important facilities to manage urban air pollution control and to set up an environmental policy. Since air quality monitoring network of Daegu was allocated from 1980s to mid-90s, there is need to reevaluate it and relocated its site. This study was evaluated the position of Daegu air quality monitoring station by unit environmental sensitivity index, grid emission rate, CAI (Comprehensive Air-quality Index) point. The investigation domain covered an area of 16 $\times$ 24 km centered at the metropolitan area of Daegu with grid spacing of 2 km. The location of alternative air quality monitoring networks was selected through optimization and quintiles analysis of total score. The result showed that all things considered, new air quality monitoring network need to install grid numbers 10, 28, 36, 37, 46. We also recommand three scenarios of alternative air quality monitoring network when considering unit environmental sensitivity index, emission rate and CAI point.

Analysis on MAUP' Effects in Visibility Analysis using GIS (가시권 분석에서의 MAUP 영향 분석)

  • Lee, Joon-Hak;Kim, Hang-Deuk;Oh, Kyoung-Doo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.80-87
    • /
    • 2009
  • The purpose of this study is to analyze the MAUP's effect in visibility analysis using GIS. MAUP normally occurs in the process in terrain spatial analysis including visibility analysis. There are two different types of grid data(based on digital map and Digital Terrain Elevation Data) and 10 different types of areal units are made for modeling, such as $5m{\times}5m,\;10m{\times}10m,\;15m{\times}15m,\;20m{\times}20m,\;25m{\times}25m,\;30m{\times}30m,\;35m{\times}35m,\;40m{\times}40m,\;45m{\times}45m,\;50m{\times}50$. By analyzing the result, it was possible to observe varying viewshed areas according to different grid cell sizes and the viewshed area did not varied linearly as expected. From a general point of view, smaller unit data map out the real world in more detail, but the results of modeling do not always reach a good conclusion when data are used in modeling for terrain analysis because of the MAUP' effect. The grid cell sizes of 30m or less seems to be adequate for visibility analysis, including terrain analysis considering vegetation heights.

Solar Inverter with Grid Power Generation

  • Suchitra Khoje;Govind Wanje;Ramesh Mali
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.9
    • /
    • pp.162-165
    • /
    • 2023
  • Power can be generated from either renewable or non-renewable sources. Renewable sources are liked to maintain a strategic distance from contamination emanation and rely on upon fossil energizes which is decreasing day by day. The proposed sun powered vitality transformation unit comprises of a sun oriented exhibit, Bidirectional DC-DC converter, single stage inverter and AC. The inverter changes over DC control from the PV board into AC power and offered it to the heap which is associated with the lattice. The photovoltaic sun powered vitality (PV) is the most direct approach to change over sunlight based radiation into power and depends on the photovoltaic impact. The most extreme power point following of the PV yield for all daylight conditions is a key to keep the yield control per unit cost low for fruitful PV applications. Framework associated PV frameworks dependably have an association with people in general power matrix by means of an appropriate inverter in light of the fact that a PV module conveys just dc power. This project presents the new design, Development and Performance Analysis of a Grid Connected PV Inverter. Demonstrate that the proposed framework can lessen the Energy Consumption radically from the power board and give a solid support to the Grid.

Power Sharing Method for a Grid connected Microgrid with Multiple Distributed Generators

  • Nguyen, Khanh-Loc;Won, Dong-Jun;Ahn, Seon-Ju;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.459-467
    • /
    • 2012
  • In this paper, a grid connected microgrid with multiple inverter-based distributed generators (DGs) is considered. DG in FFC mode regulates the microgrid as a controllable load from the utility point of view as long as its output is within the capacity limit. The transition mode causes a change in frequency of microgrid due to the loss of power transferred between main grid and microgrid. Frequency deviation from the nominal value can exceed the limit if the loss of power is large enough. This paper presents a coordinated control method for inverter-based DGs so that the microgrid is always regulated as a constant load from the utility viewpoint during grid connected mode, and the frequency deviation in the transition mode is minimized. DGs can share the load by changing their control modes between UPC and FFC and stabilize microgrid during transition.

The study on construction of the practical testing ground of grid-connected photovoltaic system (태양광발전 계통연계 실증시험장 구축에 관한 연구)

  • Kim, Euihwan;Jang, Juyeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • Currently the variety of governmental business support and research for supplying solar energy have been actively progressed. As of now, however, There are no practical testing infrastructures of grid-connected photovoltaic system which test performance of solar power facility in domestic. Therefore, in KEPRI, there is in progress construction of practical testing ground of 500 kW class grid-connected PV System for developing the evaluation of the performance technology including the Module, PCS, and etc, that is the important instrument of the PV System, in Gochang area. It analyzed the site creation work for constructing the practical testing ground and new construction of control room and the unit standards, specifications and capacity of required equipment. For the system detailed design, configuration, instrument-specific parameters established, power generation predictions of Array Type and the components of testing ground are needed to build.

  • PDF

Surge Immunity Performance Enhancement Techniques on Battery Management System (전지관리장치(BMS)의 서지내성 성능향상 기법)

  • Kim, Young-Sung;Rim, Seong-Jeong;Seo, Woohyun;Jung, Jeong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.196-200
    • /
    • 2015
  • The switching noise in the power electronics of the power conversion equipment (Power Conditioning System) for large energy storage devices are generated. Since the burst-level transient noise from being generated in the power system at a higher power change process influences the control circuit of the low voltage driver circuit. Noise may cause the malfunction of the control device even if no dielectric breakdown leads to a control circuit. To overcome this, this paper proposes the installation of an additional nano-surge protection device on the power supply DC output circuit of the battery management unit.

A STUDY OF THE APPLICATION OF DELAUNAY GRID GENERATION ON GPU USING CUDA LIBRARY (GPU Library CUDA를 이용한 효율적인 Delaunay 격자 생성에 관한 연구)

  • Song, J.H.;Kang, S.H.;Kim, G.M.;Kim, B.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.194-198
    • /
    • 2011
  • In this study, an efficient algorithm for Delaunay triangulation of a number of points which can be used on a GPU-based parallel computation is studied The developed algorithm is programmed using CUDA library. and the program takes full advantage of parallel computation which are concurrently performed on each of the threads on GPU. The results of partitioned triangulation collected from the GPU computation requires proper stitching between neighboring partitions and calculation of connectivities among triangular cells on CPU In this study, the effect of number of threads on the efficiency and total duration for Delaunay grid generation is studied. And it is also shown that GPU computing using CUDA for Delaunay grid generation is feasible and it saves total time required for the triangulation of the large number points compared to the sequential CPU-based triangulation programs.

  • PDF

A selective effect of grid and window net in the shrimp beam trawl fishery (새우조망 어업에서 그리드와 윈도우 네트의 선택효과)

  • JANG, Choong-Sik;CHO, Youn-Hyoung;AN, Young-Su
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.3
    • /
    • pp.375-386
    • /
    • 2015
  • The study aims at a selective effect of the Grid and Window net in the shrimp beam trawl. The experimental trawling of the Proto type, Grid type and Grid and Window net type was performed in a sea area of Geo-je and Tong-yeong from Mar, 2006 to Apr, 2010. The obtained results are as follows; Catch per unit area (Number) of the Proto type net and Grid type net were $0.18/m^2$, $0.23/m^2$, respectively. The Grid type demonstrated 2.4% lower bycatch rate than the proto type (6.6% vs 4.2%, respectively). In addition, in terms of total weight, the bycatch rate of Grid type was 7.6% lower than the proto type (50.2% vs 42.6%, respectively). In the comparison of shrimp catch, the Proto type demonstrated better haul outcome ($0.02case/m^2$) than the Grid & Window type ($0.02case/m^2$). The Grid & Window net type demonstrated 16.4% lower bycatch rate than the Proto type (32.2% vs 48.6%, respectively). In addition, in terms of total weight, the bycatch rate of Grid & Window net type was 8.3% lower than the Proto type (85.9% vs 94.2% respectively).

Optimal Electricity and Heat Production Strategies of Fuel Cell Device in a Micro-grid Energy System (마이크로 전력계통에서 연료전지 발전시스템의 전기/열의 최적운영 기법 연구)

  • Lee, Joo-Won;Park, Jong-Bae;Kim, Su-Duk;Kim, Chang-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1093-1099
    • /
    • 2009
  • Alternative energy sources such as renewable energy like solar power systems, wind power systems, or fuel cell power systems has been the rising issue in the electrical power system. This paper discusses an economic study analysis of fuel cells in the korean electricity market. It includes the basic concept of a fuel cell and the korean electricity market. It also describes the need of renewable energy and how the fuel cell is connected with the local grid. This paper shows the impact of production and recovering thermal energy of a grid-connected fuel cell power system. The profit maximization approach has been structured including electrical power trade with the local grid and heat trade within the micro-grid. The strategies are evaluated using a local load that uses electric and thermal power which has different patterns between summer and winter periods. The solution algorithm is not newly developed one, but is solved by an application called GAMS. Results indicate the need and usefulness of a fuel cell power system.