• 제목/요약/키워드: Grid Generation

검색결과 1,130건 처리시간 0.032초

오픈 와인딩 머신을 이용한 계통 연계형 분산 발전 시스템의 제어 (Control of an Open Winding Machine in a Grid-Connected Distributed Generation System)

  • 곽무신;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.83-86
    • /
    • 2006
  • A grid-connected distributed generation system which consists of engine generator, dc link with multiple energy sources and inverter is proposed. All six of the stator leads of the generator, which is a surface mount permanent magnet machine, are brought out to the terminal of the generator. Three leads are connected to the inverter and the others are connected to the utility grid. In this proposed system the power from the engine-generator and the power from dc link can be controlled simultaneously by only one three-phase power converter. A control algorithm for the system is developed and verified by experiment results.

  • PDF

계통연계형 태양광발전시스템의 동특성 모델링 및 모의해석 (Modeling and Simulation Analysis of Grid-Connected Photovoltaic Generation System in terms of Dynamic behavior)

  • 김응상;김슬기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.127-131
    • /
    • 2005
  • The paper addresses modeling and analysis of a grid-connected photovoltaic generation system (PV system). PSCAD/EMIDC. an industry standard simulation tool for studying the transient behavior of electric power system and apparatus. is used to conduct all aspects of model implementation and to carry out extensive simulation study. An equivalent circuit model of a solar cell has been used for modeling solar array. A PWM voltage source inverter (VSI) and its current control scheme have been implemented. A maximum power point tracking (MPPT) technique is employed for drawing the maximum available energy from the PV array. Comprehensive simulation results are presented to examine PV array behaviors and PV system control performance in response to irradiation changes. In addition, dynamic responses of PV array and system to network fault conditions are simulated and analysed

  • PDF

분산전원의 제어 특성을 고려한 마이크로그리드의 블랙 스타트 및 계통 동기화 전략 (Black Start and Synchronization of Microgrid Considering Distributed Generation Control)

  • 최진영;원동준
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.898-904
    • /
    • 2013
  • In order to minimize the damage from power outage, power system should be restored quickly. In this paper, a procedure for the restoration of microgrid is proposed. After elimination of the causes of power outage, a black start algorithm is executed by considering the characteristics of distributed generation control. After all resources have been recovered to the normal state, a grid reconnecting algorithm for stable operation in grid-connected mode is performed. In order to verify the proposed algorithm, low voltage microgrid is simulated using PSCAD/EMTDC.

Simulink에서 계통연계 풍력발전시스템의 전압변동 시뮬레이션 (Simulation for Voltage Variations of a Grid-connected Wind Turbine Generation System by Simulink)

  • 안덕근;노경수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권11호
    • /
    • pp.589-595
    • /
    • 2004
  • This paper presents a modeling and simulation of a grid-connected wind turbine generation system with respect to wind variations, starting of large induction motor and three-phase fault in the system, and investigates voltage variations of the system for disturbances. It describes the modeling of the wind turbine system including the drive train model, induction generator model, and grid-interface model on MATLAB/Simulink. The simulation results show the variation of the generator torque, the generator rotor speed, the pitch angle, terminal voltage, system voltage, fault current, and real/reactive power output, etc. Case studies demonstrate that the pitch angle control is carried out to achieve maximum power extraction for wind speed variations, starting of a large induction motor causes a voltage sag due to a large starting current, and a fault on the system influences on the output of the wind turbine generator.

마이크로 가스터빈 열병합 발전시스템 성능평가 (Performance Test of MGT Combined Heat & Power System)

  • 허광범;박정극;임상규
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.313-316
    • /
    • 2006
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. Korea Electric Power Corporation (KEPCO) has researched performance characteristics of the 60k W class 1) basic start-up & shutdown operation analysis 2) interconnection test 3) MGT -absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

3 kW 계통연계형 태양광 발전시스템의 설계 및 실증운전특성 분석 (Design and Characteristics Analysis of a 3 kW Grid-connected Photovoltaic Power Generation System)

  • 황인호;정승주;안교상;임희천
    • 태양에너지
    • /
    • 제18권1호
    • /
    • pp.19-25
    • /
    • 1998
  • This paper describes a design method and characteristics analysis of the 3 kW grid-connected photovoltaic power generation system to establish the basic application technology of photovoltaic systems. The design specification of a 3 kW photovoltaic power generation system including a DC/AC inverter is suggested to investigate the system performance for grid connection. The results of the demonstration test from February to October show that the system with utilization rate up to 17% has reliable operation characteristics and is useful for peak-shaving of utility power.

  • PDF

농형 유도발전기를 이용한 계통 연계형 풍력발전 시스템 (Grid-Connected Wind Power Generation System Using Cage-Type Induction Generators)

  • 김형균;;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.73-76
    • /
    • 2003
  • This paper proposes a maximum output power control of grid-connected wind power generation system using cage-type induction generators. For generator control, indirect vector control is used, where d-axis current controls the excitation level and q-axis current controls the generator speed. The generated power flows into the utility through the grid-side converter, by which the do link voltage is controlled to be constant and the ac current is controlled in sinusoid and. The generator speed is adjusted according to wind speed for extracting maximum power generation. Experimental results are shown to verify the validity of the proposed scheme.

  • PDF

자바 애플릿을 이용한 2차원 혼합형 비정렬 격자 생성 프로그램의 개발 (DEVELOPMENT OF 2-D UNSTRUCTURED HYBRID GRID GENERATION PROGRAM USING JAVA APPLET)

  • 이장훈;조금원;김병수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 추계학술대회논문집
    • /
    • pp.65-70
    • /
    • 2009
  • In this paper a hybrid grid generation program for general 2-D region is introduced. The program is developed by using JAVA programming language, and it can be used either as an application program on a local computer or as an applet in the network environment. The hybrid grid system for a 2-D problem means a combination of triangular cells and quadrilateral cells, and it can offer both of the high flexibility of triangular cells and the high accuracy and efficiency of structured-type quadrilateral cells. To accommodate a quadrilateral-cell region and a triangular-cell region into one computational domain, it is importance to take good care of the interface between two different regions so that overall good grid quality can be maintained. In this research advancing layer method(ALM) augmented by elliptic smoothing method is used for the quadrilateral-cell region and advancing front method(AFM) is used for the triangular-cell region. A special treatment technique for the interface between those two regions is also developed. The interface treatment technique is basically to prevent the propagation of small cell size due to ALM method into the triangular region and maintain the smooth transition of cell-size scale between two different regions. By applying current technique high-quality hybrid grids for general 2-D regions can be easily generated, and typical grid generation results and flow solutions are demonstrated.

  • PDF

영사식 3차원 형상 측정을 위한 격자무늬 생성장치에 관한 연구 (A study on the grid fringe generator for measurement of 3-D object)

  • 박윤창
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.170-175
    • /
    • 1999
  • Noncontact measuring methodology of 3-dimensional profile using CCD camera are very attractive because of it's high measuring speed and its's high sensitivity. Especially, when projecting a grid pattern over the object the captured image have 3 dimensional information of the object. Projection moire extract 3-D information with another grid pattern in front of CCD camera. However phase measuring profilometry(PMP) obtain similar results without additional grid pattern. In this paper, new method for grid pattern generation system by polygonal mirror and Laser Diode. This system is applied the projection moire and the PMP.

  • PDF