• 제목/요약/키워드: Grid Damage

검색결과 180건 처리시간 0.03초

Assessment of seismic risk of a typical RC building for the 2016 Gyeongju and potential earthquakes

  • Jee, Hyun Woo;Han, Sang Whan
    • Earthquakes and Structures
    • /
    • 제20권3호
    • /
    • pp.337-351
    • /
    • 2021
  • On September 12, 2016, the Gyeongju earthquake occurred in the south-eastern region of the Korean peninsula. The event was ranked as the largest magnitude earthquake (=5.8) since instrumental recording was started by the Korean Metrological Administration (KMA) in 1978. The objective of this study is to provide information obtained from the 2016 Gyeongju earthquake and to propose a procedure estimating seismic risk of a typical old RC building for past and potential earthquakes. Ground motions are simulated using the point source model at 4941 grid locations in the Korean peninsula that resulted from the Gyeongju earthquake and from potential future earthquakes with the same hypocenter considering different soil conditions. Nonlinear response history analyses are conducted for each grid location using a three-story gravity-designed reinforced concrete (RC) frame that most closely represents conventional old school and public buildings. Then, contour maps are constructed to present the seismic risk associated with this building for the Gyeongju earthquake and potential future scenario earthquakes. These contour maps can be useful in the development of a mitigation plan for potential earthquake damage to school and public buildings at all grid locations on the Korean peninsula.

Seismic failure analysis and safety assessment of an extremely long-span transmission tower-line system

  • Tian, Li;Pan, Haiyang;Ma, Ruisheng;Dong, Xu
    • Structural Engineering and Mechanics
    • /
    • 제71권3호
    • /
    • pp.305-315
    • /
    • 2019
  • Extremely long-span transmission tower-line system is an indispensable portion of an electricity transmission system, and its failures or collapse can impact on the entire electricity grid, affect the modern life, and cause great economic losses. It is therefore imperative to investigate the failure and safety of the transmission tower subjected to ground motions. In the present study, a detailed finite element (FE) model of a representative extremely long-span transmission tower-line system is established. A segmental damage indicator (SDI) is proposed to quantitatively assess the damage level of each segment of the transmission tower under earthquakes. Additionally, parametric studies are conducted to investigate the influence of different ground motions and incident angles on the ultimate capacity and weakest segment of the transmission tower. Finally, the collapse fragility curve in terms of the maximum SDI value and PGA is plotted for the exampled transmission tower. The results show that the proposed SDI can quantitatively assess the damage level of the segments, and thus determine the ultimate capacity and weakest segment of the transmission tower. Moreover, the different ground motions and incident angles have a significant influence on the SDI values of the transmission tower, and the collapse fragility curve is utilized to evaluate the collapse resistant capacity of the transmission tower subjected to ground motions.

An approach for optimal sensor placement based on principal component analysis and sensitivity analysis under uncertainty conditions

  • Beygzadeh, Sahar;Torkzadeh, Peyman;Salajegheh, Eysa
    • Structural Monitoring and Maintenance
    • /
    • 제9권1호
    • /
    • pp.59-80
    • /
    • 2022
  • In the present study, the objective is to detect the structural damages using the responses obtained from the sensors at the optimal location under uncertainty conditions. Reducing the error rate in damage detection process due to responses' noise is an important goal in this study. In the proposed algorithm for optimal sensor placement, the noise of responses recorded from the sensors is initially reduced using the principal component analysis. Afterward, the optimal sensor placement is obtained by the damage detection equation based sensitivity analysis. The sensors are placed on degrees of freedom corresponding to the minimum error rate in structural damage detection through this procedure. The efficiency of the proposed method is studied on a truss bridge, a space dome, a double-layer grid as well as a three-story experimental frame structure and the results are compared. Moreover, the performance of the suggested method is compared with three other algorithms of Average Driving Point Residue (ADPR), Effective Independence (EI) method, and a mass weighting version of EI. In the examples, young's modulus, density, and cross-sectional areas of the elements are considered as uncertainty parameters. Ultimately, the results have demonstrated that the presented algorithm under uncertainty conditions represents a high accuracy to obtain the optimal sensor placement in the structures.

계통 연계형 PV 시스템의 고립운전 검출기법의 성능개선 (Performance Improvement of Islanding Detection Technique in Photo-Voltaic System)

  • 최철훈;최종우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.378-379
    • /
    • 2011
  • PV system's islanding occurs when the uitilty grid is removed but local sources continue to operate and provide power to local loads. Islanding is one of the serious problems in an electric power system connected with dispersed power sources. Also, this can present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding detection by passive methods becomes difficult. Novel islanding detection method is proposed for grid-connected PV system.

  • PDF

Islanding Detection for PV System Connected to a Utility Grid

  • Han, Seok-Woo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.719-723
    • /
    • 1998
  • Prevention of the islanding phenomena is one of the most important issues because it can damage electrical equipment connected to the utility system and endanger human life. It is very difficult to detect an islanding condition of a power distribution line with conventional voltage of frequency relays, while the output power and the load power of utility interactive PV inverter units are in nearly balanced state in both active power and reactive power. This paper describes the protective equipment that prevents the PV system connected to the utility grid from starting islanding. Both predictive ocntrol method and harmonic injection method are used for a current control and islanding detection for operating safety.

  • PDF

A Study on Third Body Abrasion in the Small Clearance Region Adjacent to the Contact Area

  • Kim, Hyung-Kyu;Lee, Young-Ho;Heo, Sung-Pil;Jung, Youn-Ho
    • KSTLE International Journal
    • /
    • 제4권1호
    • /
    • pp.8-13
    • /
    • 2003
  • Abrasion in fretting wear mechanism is studied experimentally with the specimens of two different shapes of spacer grid spring and fuel tubes of a nuclear fuel. Reciprocating sliding wear test has been carried out in the environment of air and water at room temperature. Especially, third body abrasion is referred to for explaining the wear region expansion found during the slip displacement increase with constant normal contact farce. It is found that the expansion behaviour depends on the contact shape. The small clearance between the tube and spring seems to be the preferable region of the wear particle accumulation, which causes third body abrasion of the non-contact area. Even in water environment the third body abrasion occurs apparently. Since the abrasion on the clearance contributes wear volume, the influence of the contact shape on the severity of third body abrasion should be considered to improve the grid spring design in the point of restraining wear damage of a nuclear fuel.

계통연계형 PV 인버터의 자동 위상 이동법에 의한 고립운전 검출 (Islanding detection of grid-connected photovoltaic inverters using Automatic phase-shift method)

  • 윤중혁;김흥근;최종우;전태원;이홍희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.591-594
    • /
    • 2005
  • Islanding of PV systems occurs when the uitilty grid is removed but local sources continue to operate and provide power to local loads. Islanding Is one of the serious problems in an electric power system connected with dispersed power sources. Also, this scan present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding phenomena can't be detected by the passive methods. Several active methods were proposed to detect islanding phenomena. The most effective method is SFS method which was suggested by Sandia National Laboratory. In this paper, a new anti-islanding algorithm is proposed and its validity is verified through simulation and experimental results for utility interconnection of PV system.

  • PDF

계통 연계 풍력발전단지의 운전효율 향상을 위한 배전 계통의 적응형 보호 계전 알고리즘 (An Adaptive Relaying Algorithm on Utilities' Electrical Feeders for Improving the Reliable Operation of Wind Farm Interconnected with Utility Grid)

  • 장성일;김지원;최돈만;김광호;김형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.338-341
    • /
    • 2003
  • This paper proposes the adaptive relaying algorithm of protective devices applied in the neighboring distribution feeders for reliable and efficient operations of a wind farm interconnected with distribution networks by dedicated lines. Generally, it would be highly possible that the wind turbine generators are influenced by abnormal grid conditions such as disturbances occurring in the neighboring distribution feeders as well as the dedicated power line. The delayed operation time of protective devices for satisfying the coordination might overly expose the interconnected wind turbine generators to the fault and cause damage to them. In order to reduce the damages on the interconnected wind farm about the faults happening in distribution networks, this paper describes the proper delayed operation time of protective relay.

  • PDF

가상 지진해일에 의한 동해안에서의 피해 예측 (The prediction of maximum wave height for virtual tsunami in the eastern coast of the Korea)

  • 심주열;최문규;조용식
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.229-232
    • /
    • 2008
  • The Central East Sea Tsunami caused huge damage to the eastern coast of the Korean Peninsula, eapecially Imwon port was damaged relatively strongly beacause of water depth variation which makes the wave concentration on this port. there are many virtual tsunami in east sea which has a possibility of happening. So, it is very important to expect the region which may be damaged by vritual tsunmis. In this study, modified dispersion-correction terms are used. The modified scheme has the advantage of using the constant spatial grid size and time step size even in real topography. Dynamic linking technique and staggered grid system are used. Using this model some cases of virtual tsunami was simulated and check the region which is occured maximum wave heights on the eastern sea of the Korean peninsula.

  • PDF

소아 흉부검사 시 격자 사용에 따른 영상 화질 평가 (Evaluation of Image Quality When Using Grid During Child Chest X-Ray Examination)

  • 정성훈;한범희;정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.371-376
    • /
    • 2017
  • 소아의 경우 방사선의 감수성이 성인에 비하여 높고, 잠재적 피폭으로 인한 장해가 발생할 수 있으므로 피폭선량에 대해 관리가 요구된다. 이에 본 연구는 소아 흉부검사 시 산란선을 제거시켜주지만 피폭선량을 증가시키는 격자(Grid)의 사용 유, 무에 따른 영상과 거리와 조건의 변화에 따른 영상을 분석하여 소아 흉부검사에서 적정한 검사조건을 제시하고자 하였다. 연구방법은 Grid를 부착한 상태에서 100 cm, 180 cm에서 측정하였으며, kVp를 70. 90. 110으로 변화하여 측정하였다. 또한 Grid를 미부착한 상태에서 100 cm, 180 cm을 고정 시키고, 선량을 6, 8, 10 mAs로 변화시켜 측정하였으며, 측정항목은 신호 대 잡음비, 대조도 대 잡음비, J.J Vucich를 측정하였다. kVp를 고정시켜 측정한 결과 초점-이미지 수용체간 거리가 100 cm일 때 신호 대 잡음비, 대조도 대 잡음비, J.J Vucich가 모두 높게 나타났다. 또한, 선량(mAs)을 변화시켜 측정한 결과 신호 대 잡음비, 대조도 대 잡음비, J.J Vucich에서 초점-이미지 수용체 간 거리 100 cm에서 높게 나타났다. 현재 국내에서 흉부검사는 일반적으로 180 cm으로 시행하고 있지만 본 연구결과에서는 소아의 흉부 검사 시 초점-이미지수용체간 거리가 100 cm일 때 영상평가에서 화질이 높게 평가되었다.