• Title/Summary/Keyword: Grid Configuration

Search Result 235, Processing Time 0.032 seconds

The study on construction of the practical testing ground of grid-connected photovoltaic system (태양광발전 계통연계 실증시험장 구축에 관한 연구)

  • Kim, Euihwan;Jang, Juyeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • Currently the variety of governmental business support and research for supplying solar energy have been actively progressed. As of now, however, There are no practical testing infrastructures of grid-connected photovoltaic system which test performance of solar power facility in domestic. Therefore, in KEPRI, there is in progress construction of practical testing ground of 500 kW class grid-connected PV System for developing the evaluation of the performance technology including the Module, PCS, and etc, that is the important instrument of the PV System, in Gochang area. It analyzed the site creation work for constructing the practical testing ground and new construction of control room and the unit standards, specifications and capacity of required equipment. For the system detailed design, configuration, instrument-specific parameters established, power generation predictions of Array Type and the components of testing ground are needed to build.

  • PDF

Analysis and Design of LCL Filter with Passive Damping Circuits for Three-phase Grid-connected Inverters

  • Ahn, Hyo Min;Oh, Chang-Yeol;Sung, Won-Yong;Ahn, Jung-Hoon;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.217-224
    • /
    • 2017
  • The analysis and design process of the LCL filter with passive damping circuits for three-phase grid-connected inverter are presented based on the generalized model of LCL filter. Several types of the passive damping circuits in previous studies could be compared and analyzed by using the generalized model considering various design criteria of passive damping circuits. According to the analysis in this paper, a reasonable configuration of passive damping circuits for three-phase grid-connected inverters is proposed. The validity of the proposed design process is verified by informative simulation and experimental results.

Efficiency of Vitrification using Conventional Straw and Grid as a Vihicle in Mouse Oocytes (마우스 성숙난자의 Straw와 Grid를 이용한 유리화동결법의 효율성 검토)

  • 정형민;박이석;박성은
    • Journal of Embryo Transfer
    • /
    • v.16 no.3
    • /
    • pp.233-237
    • /
    • 2001
  • To develop an effective vitrification method, we examined the use of a conventional straw as vessel fur vitrification of mouse oocytes, and to compare the post-thaw survival and chromosome configuration of these oocytes with those vitrified in grids. Intact cumulus-enclosed oocytes were vitrified with DPBS with 5.5 M ethylene glycol and 1.0 M sucrose, and loaded into straws and onto eletron microscopic copper grid fur storing in liquid nitrogen. Intact vitrified and thawed oocytes were karyotying for chromosome. The rates of post-thawed survival were 88.5% in vitrified oocytes with straws, and 83% in vitrified ooctyes with grids. Vitrified and thawed oocytes with straws and grids were increased chromosomal abnormality (31.4% and 30.9%) compared with fresh oocytes (17.8%). The conventional straws can be used as vessel for vitrification to prevent of inflection in liquid nitrogen.

  • PDF

A Study on the Effect of Distributed Generation of the Reconfiguration of Distribution Networks

  • Nguyen, Tung Linh;Trinh, Trong Chuong;Truong, Viet Anh
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1435-1441
    • /
    • 2017
  • Distributed generation (DG) in the future will play an important role in the electricity supply systems, in wich can provide DG capacity from a few hundred kW to tens of MW. However, it is connected to the local power grid, DG will have certain influence on the power quality of the power grid. One of the most significant effects is that they will change the configuration of the local power grid as well as affecting the operation mode of the grid. This paper presents a method of finding the optimal open loop, analyzing and selecting the appropriate mode of operation to reduce power losses of power distribution networks that includes DG.

Single-Phase Inverter for Grid-Connected and Intentional Islanding Operations in Electric Utility Systems

  • Lidozzi, Alessandro;Lo Calzo, Giovanni;Solero, Luca;Crescimbini, Fabio
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.704-716
    • /
    • 2016
  • Small distributed generation units are usually connected to the main electric grid through single-phase voltage source inverters. Grid operating conditions such as voltage and frequency are not constant and can fluctuate within the range values established by international standards. Furthermore, the requirements in terms of power factor correction, total harmonic distortion, and reliability are getting tighter day by day. As a result, the implementation of reliable and efficient control algorithms, which are able to adjust their control parameters in response to changeable grid operating conditions, is essential. This paper investigates the configuration topology and control algorithm of a single-phase inverter with the purpose of achieving high performance in terms of efficiency as well as total harmonic distortion of the output current. Accordingly, a Second Order Generalized Integrator with a suitable Phase Locked Loop (SOGI-PLL) is the basis of the proposed current and voltage regulation. Some practical issues related to the control algorithm are addressed, and a solution for the control architecture is proposed, based on resonant controllers that are continuously tuned on the basis of the actual grid frequency. Further, intentional islanding operation is investigated and a possible procedure for switching from grid-tied to islanding operation and vice-versa is proposed.

Efficient Server Virtualization using Grid Service Infrastructure

  • Baek, Sung-Jin;Park, Sun-Mi;Yang, Su-Hyun;Song, Eun-Ha;Jeong, Young-Sik
    • Journal of Information Processing Systems
    • /
    • v.6 no.4
    • /
    • pp.553-562
    • /
    • 2010
  • The core services in cloud computing environment are SaaS (Software as a Service), Paas (Platform as a Service) and IaaS (Infrastructure as a Service). Among these three core services server virtualization belongs to IaaS and is a service technology to reduce the server maintenance expenses. Normally, the primary purpose of sever virtualization is building and maintaining a new well functioning server rather than using several existing servers, and in improving the various system performances. Often times this presents an issue in that there might be a need to increase expenses in order to build a new server. This study intends to use grid service architecture for a form of server virtualization which utilizes the existing servers rather than introducing a new server. More specifically, the proposed system is to enhance system performance and to reduce the corresponding expenses, by adopting a scheduling algorithm among the distributed servers and the constituents for grid computing thereby supporting the server virtualization service. Furthermore, the proposed server virtualization system will minimize power management by adopting the sleep severs, the subsidized servers and the grid infrastructure. The power maintenance expenses for the sleep servers will be lowered by utilizing the ACPI (Advanced Configuration & Power Interface) standards with the purpose of overcoming the limits of server performance.

Numerical Simulation for Transonic Wing-Body Configuration using CFD (CFD를 이용한 천음속 날개-동체 형상 해석)

  • Kim, Younghwa;Kang, Eunji;Ahn, Hyokeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.3
    • /
    • pp.233-240
    • /
    • 2017
  • The flowfield around transonic wing-body configuration was simulated using in-house CFD code and compared with the experimental data to understand the influence of several features of CFD(Computational Fluid Dynamics) ; grid dependency, turbulence models, spatial discretization, and viscosity. The wing-body configuration consists of a simple planform RAE Wing 'A' with an RAE 101 airfoil section and an axisymmetric body. The in-house CFD code is a compressible Euler/Navier-Stokes solver based on unstructured grid. For the turbulence model, the $k-{\omega}$ model, the Spalart-Allmaras model, and the $k-{\omega}$ SST model were applied. For the spatial discretization method, the central differencing scheme with Jameson's artificial viscosity and Roe's upwind differencing scheme were applied. The results calculated were generally in good agreement with experimental data. However, it was shown that the pressure distribution and shock-wave position were slightly affected by the turbulence models and the spatial discretization methods. It was known that the turbulent viscous effect should be considered in order to predict the accurate shock wave position.

Independent Generation System Design for the Economic Management of Electrical Charging Stations (전기충전소의 경제적 운영을 위한 독립발전 시스템 설계)

  • Seo, Jin-Gyu;Kim, Kyu-Ho;Rhee, Sang-Bong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.222-227
    • /
    • 2015
  • This paper presents the optimal energy generation systems for economical EVs(Electric Vehicles) charging stations located in an island area. The system includes grid electricity, diesel generator and renewable energy sources of wind turbines and PV(Photovoltaic) panels. The independent generation system is designed with data resources such as annual average wind speed, solar radiation and the grid electricity price by calculating system cost under different structures. This sensitive analysis on the varying data resources allows for the configuration of the most economical generation system for charging stations by comparing initial capital, operating cost, NPC(Net Present Cost) and COE(Cost of Energy). Depending on the increase of the grid cost, the NPC variation of the most economical system which includes renewable energy generations and grid electricity can be smaller than those of other generation systems.

A Development of 2MVA Battery Energy Storage System (2MVA급 배터리 에너지 저장시스템 개발)

  • Kim, Soo-Hong;Kim, Tae-Hyeong;Kim, Yun-Hyun;In, Dong-Seok;Kwon, Byung-Ki;Choi, Chang-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.174-181
    • /
    • 2012
  • Energy storage system connected to the grid has two functions such as the surplus power of a grid is stored in batteries or the energy stored in batteries will supply to the grid when the grid needs. The battery energy storage system consist of power condition system (PCS) for power supply and battery conditioning system (BCS). Lithium-ion batteries are mainly used. In this paper, the battery energy storage system connected to the grid described. The configuration of the 2MVA class power control system using water cooling and battery system are presented. And control method for the system and the output filter design method are proposed. Experimental verification of the proposed system is provided with 2MVA PCS and 500kWh BCS.

Numerical Analysis on Separation Dynamics of Multi-stage Rocket System Using Parallelized Chimera Grid Scheme (병렬화된 Chimera 격자 기법을 이용한 다단 로켓의 단분리 운동 해석)

  • Ko Soon-Heum;Choi Seongjin;Kim Chongam;Rho Oh-Hyun;Park Jeong-joo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.47-52
    • /
    • 2002
  • The supersonic flow around multi-stage rocket system is analyzed using 3-D compressible unsteady flow solver. A Chimera overset grid technique is used for the calculation of present configuration and grid around the core rocket is composed of 3 zones to represent fins in the core rocket. Flow solver is parallelized to reduce the computation time, and an efficient parallelization algorithm for Chimera grid technique is proposed. AUSMPW+ scheme is used for the spatial discretization and LU-SGS for the time integration. The flow field around multi-stage rocket was analyzed using this developed solver, and the results were compared with that of a sequential solver The speed-up ratio and the efficiency were measured in several processors. As a result, the computing speed with 12 processors was about 10 times faster than that of a sequential solver. Developed flow solver is used to predict the trajectory of booster in separation stage. From the analyses, booster collides against core rocket in free separation case. So, additional jettisoning forces and moments needed for a safe separation are examined.

  • PDF