• 제목/요약/키워드: Grid Charging

검색결과 159건 처리시간 0.023초

계통연계형 풍력, 태양광 및 축전지 하이브리드 시스템의 출력제어 및 동특성 해석 (Power Control and Dynamic Performance Analysis of a Grid-Interactive Wind/PV/BESS Hybrid System)

  • 김슬기;전진홍;조창희;안종보
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.317-324
    • /
    • 2007
  • Most conventional hybrid systems using renewable energy sources have been applied for stand-alone operation, but Utility-interface may be an useful and viable option for hybrid systems. Grid-connected operation may have benefits such as reduced losses in power system distribution, utility support in demand side management, and peak load shaving. This paper addresses power control and dynamic performance of a grid-connected PV/wind/BESS hybrid system. At all times the PV way and the wind turbine are individually controlled to generate the maximum energy from given weather conditions. The battery energy storage system (BESS) charges or discharges the battery depending on energy gap between grid invertger generation and production from the PV and wind system. The BESS should be also controlled without too frequently repeated shifts in operation mode, charging or discharging. The grid inverter regulates the generated power injection into the grid. Different control schemes of the grid inverter are presented for different operation modes, which include normal operation, power dispatching, and power smoothing. Simulation results demonstrate that the effectiveness of the proposed power control schemes for the grid-interactive hybrid system.

전기자동차용 통합충전기의 모델링 및 전류제어기 설계 (Modeling and Current Controller Design of Integrated Charger)

  • 허건;박용순
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.42-44
    • /
    • 2018
  • An integrated charger is used for bi-directional power conversion between an electric vehicle and a power grid. The proposed integrated charger works in a way that motor windings are utilized as filter inductances for charging/discharging of batteries in addition to the original purpose of motor drives. After a mathematical model of the integrated charger based on an dual winding induction machine (DWIM) is discussed, a current control method is designed for grid connection. The effectiveness of the proposed method is examined with simulation results.

  • PDF

Designing Test Methods for IT-Enabled Energy Storage System to Evaluate Energy Dynamics

  • Kim, Young Gon;Kim, Dong Hoon;Lee, Eun-Kyu
    • Journal of Information Processing Systems
    • /
    • 제13권6호
    • /
    • pp.1487-1495
    • /
    • 2017
  • With increasing interests in renewables, more consumers are installing an energy storage system (ESS) in their backyards, and thus, the ESS will play a critical role in the emerging smart grid. Due to mechanical properties, however its operational dynamics must be well understood before connecting the ESS to the smart grid (and eventually to an IT system). To this end, we investigate charging and discharging processes in detail. This paper, then, proposes methods for four type tests (state of charge test, conversion efficiency test, response time test, and ramp rate test) that can assess the dynamics of the ESS. The proposed methods can capture accurate delay values of mechanical processes in the ESS, and it is expected for those values to help design real-time communication systems in the smart grid involving the ESS.

Power Distribution Control Scheme for a Three-phase Interleaved DC/DC Converter in the Charging and Discharging Processes of a Battery Energy Storage System

  • Xie, Bing;Wang, Jianze;Jin, Yu;Ji, Yanchao;Ma, Chong
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1211-1222
    • /
    • 2018
  • This study presents a power distribution control scheme for a three-phase interleaved parallel DC/DC converter in a battery energy storage system. To extend battery life and increase the power equalization rate, a control method based on the nth order of the state of charge (SoC) is proposed for the charging and discharging processes. In the discharging process, the battery sets with high SoC deliver more power, whereas those with low SoC deliver less power. Therefore, the SoC between each battery set gradually decreases. However, in the two-stage charging process, the battery sets with high SoC absorb less power, and thus, a power correction algorithm is proposed to prevent the power of each particular battery set from exceeding its rated power. In the simulation performed with MATLAB/Simulink, results show that the proposed scheme can rapidly and effectively control the power distribution of the battery sets in the charging and discharging processes.

플라즈마 표면 처리시 전도성 그리드를 통한 표면 입사 이온 에너지와 입사량 증대에 관한 분석 및 그 응용 (Analyses of incident ion energy and flux in plasma based surface treatment using a conducting grid)

  • 조용성;최원영;박현동;최준영;이해준;이호준;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.197-200
    • /
    • 2005
  • As Plasma Immersion ion Implantation (PIII) using a conducting grid is very useful to reduce the effect of capacitance and charging in surface modification. If the bias voltage applied to the conducting grid is in the range of hundreds of volts, the effects of surface charge and space charge substantially affect the incident ion energy and ion current to the surface. In this paper, through an 1d and a 2d PIC simulation the time varying formation of the space charge and surface charge is analyzed. Experiment with the optimally designed grid on the basis of the simulation results is conducted, and the results of both cases with grid and without grid are compared. In our work with Poly Urethane(PU), the improvement of adhesion is yielded by increasing surface roughness and decreasing Si component of PU.

  • PDF

전기자동차와 충전기반시설의 V2G 기술 활용과 영향에 관한 연구 (Applications and Impact of V2G Technology for Electric Vehicle and Charging Infrastructure)

  • 이성욱;박병주
    • 문화기술의 융합
    • /
    • 제5권2호
    • /
    • pp.367-373
    • /
    • 2019
  • 급격한 전기자동차의 증가에 따라 전기자동차의 배터리를 주행 목적이 아닌 다른 용도로 사용하려는 Vehicle-to-Grid (V2G) 기술 또한 산업계와 학계부터 큰 관심을 끌고 있다. V2G 기술의 도움으로 전기자동차의 배터리는 스마트 그리드 환경에서 에너지 저장장치, 전력공급원등의 여러 중요한 역할로의 사용이 가능해 진다. 본고 에서는 거주용 주택환경을 위한 기술인 Vehicle-to-Home(V2H), 상업용 건물을 위한 기술인 Vehicle-to-Building(V2B) 그리고 전체 전력망을 위한 기술인 Vehicle-to-Grid(V2G) 기술에 대해 자세히 알아보고 각 기술의 특성과 영향에 대해 검토한다. 또한 이 기술들의 경제적 영향에 대해서도 분석한다.

입·출력 전압 변동을 고려한 3상 인터리브드 양방향 DC-DC컨버터의 전류리플 저감 기법 (Current Ripple Reduction Method of 3-phase Interleaved Bidirectional DC-DC Converter with the Consideration of Input and Output Voltage Variation)

  • 선다운;정재헌;노의철;정규범
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.427-433
    • /
    • 2016
  • This paper proposes a new method for the current ripple reduction of a three-phase interleaved bidirectional DC-DC converter. Usually, the three-phase interleaved bidirectional DC-DC converter is used for battery charging and discharging to reduce battery current ripple. In V2G application, a PWM AC-DC converter is used to connect the AC power grid and three-phase interleaved bidirectional DC-DC converter for battery charging and discharging. The magnitude of DC link voltage affects the battery current ripple magnitude. Therefore, the magnitude of the battery ripple current is analyzed with variations of battery and DC link voltages. The ripple current magnitude is found to be minimized by controlling the DC link voltage. Simulation and experimental results show the usefulness of the proposed method.

전기 자동차의 충전 모델링을 이용한 배전계통 과부하 분석 (Overload Analysis of Distribution Systems make use of PEVs Charging Modeling)

  • 최상봉;이재조;성백섭
    • 에너지공학
    • /
    • 제29권3호
    • /
    • pp.74-85
    • /
    • 2020
  • 본 논문은 PEVs가 배전계통 모선에 연계되었을 때 PEVs 보급 시나리오별로 PEVs 일간 충전 패턴에 따라 배전계통 모선별 PEVs 충전 일부하곡선을 산정하여 배전계통 모선별 과부하 영향 평가를 하기 위한 알고리즘을 제시하였다. 제안한 알고리즘은 첫째 배전계통 모선별 가구 수 산출을 위한 PEVs 대수 산출, 둘째 PEVs 운행 특성을 고려한 PEVs 충전시작시간 확률밀도 함수 산출, 셋째 PEVs 보급시나리오별로 배터리 특성을 반영한 해당 모선별 PEVs 충전 일부하곡선을 산출하였다. 넷째 산출된 해당 모선별 PEVs 충전 일부하곡선과 기존 일부 하곡선을 합산하여 PEVs 보급시나리오별로 해당 모선의 과부하 영향 평가를 시행하였다. 추가로 제안된 알고리즘에 대해 배전계통 모선별 과부하 영향 평가 검증을 위해 한국 동탄 신도시의 배전계통 회선의 해당 모선(아파트, 단독주택 지역)을 대상으로 사례 검토를 실시하였다.

감액 특성 향상을 위한 하이브리드(Sb/Ca) 액식 연축전지 개발 (Development of Hybrid (Sb/Ca) Flooded Lead-Acid Battery for Minimizing Water Loss)

  • 송승윤;임태섭;김성준;정연길;양승철
    • 한국재료학회지
    • /
    • 제32권3호
    • /
    • pp.146-152
    • /
    • 2022
  • One disadvantage of deep cycle flooded lead-acid batteries is increasing water loss caused by use of (+) Pb-Sb / (-) Pb-Sb alloy grid. Water loss is generated by the emission of hydrogen gas from the (-) electrode during battery charging. In this paper, we maintain cycle life aspect through the development of hybrid flooded lead-acid batteries to which a (+) Pb-Sb / (-) Pb-Ca grid is applied and deal with the improvement of water loss. The amount of water loss compared to that of the (-) Pb-Sb grid decreased when Ca was added to the (-) Pb grid. For the (-) Pb-Ca grid, it was confirmed that the time to reach 0.0 V, at which water decomposition occurs, was increased compared to that of the (-) Pb-Sb grid at the NPV (Negative Potential Voltage). In the cycle life test conducted with the BCI (Battery Council International) standard, compared to the (+) Pb-Ca grid, the (+) Pb-Sb grid increased the life cycle of the batteries and the (+) Pb-Ca grid showed an early end of life due to PbO corrosion layer generation, as determined through SEM / EDS and Tear Down analysis. In conclusion, by addition of Sb to (+) Pb grid and Ca to (-) Pb grid, we developed a hybrid flooded lead-acid battery that meets user requirements to improve water loss characteristics and preserve cycle life characteristics.

ISO/IEC 15118기반 V2G 환경에서 전기자동차 유연성 검토 (EV Flexibility Availability for V2G Considering ISO/IEC 15118 Charging Protocol)

  • 이상환;조규상;이상영;김영우;손성용
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.91-97
    • /
    • 2021
  • 전기자동차를 이용하여 계통에 전력을 공급하는 Vehicle to Grid(V2G)의 구현을 위한 통신표준으로 ISO/IEC 15118이 적용되고 있다. 통신 프로토콜에 기반을 두는 전기자동차의 충방전 제어 시에 필연적으로 충방전 실행까지의 시간지연이 발생하게 되는데, 이러한 시간지연은 전력 유연성 공급 측면에서 제한의 요인이 된다. 본 연구에서는 ISO/IEC 15118 기반 V2G 에뮬레이터를 구현하고 전기 자동차 충방전 제어에 따른 반응성을 확인하였다. 실험결과 시간지연은 0.12ms로 나타났으며, 이를 기반으로 현 표준 하에서 참여 가능한 전력 유연성 시장에 대하여 검토하였다.